new law tenements have an exterior entrance to basement t/f
|
T
|
|
both front and rear fire escapes I dictate what?
|
Four appts per floor
|
|
celar ceiling is fireproof?
|
Yes the ceiling Is fireproof and Un pierced
|
|
what are some of the characteristics of NLT
|
Exterior walls are masonry and generally brick the roof floors and interior are partly or wholly of wood. Columns and girders of unprotected steel. H type design.
|
|
cockloft in H type building fire stopped?
|
Yes it is but sometimes can be defective and fire can get through
|
|
do H types have an open cockloft?
|
No they are divided but fire may still spread if fire walls are defective
|
|
transverse stairs
|
Located at points remote from each other but a person can go from one stairway to another via public hall on all floors
|
|
wing stairs
|
1 or 2 are located at the front and rear of each wing. Punic hall does not transverse to the other wing of the H type
|
|
wing stairs
|
1 or 2 are located at the front and rear of each wing. Punic hall does not transverse to the other wing of the H type
|
|
isolated stairs
|
Identified by there individual entrance. Floor landings are recognized by there limited space
|
|
what concern are channel rails in an H type?
|
Steel columns erected vertically. Located in bounds behind closets. Main concern is not being fire stopped
|
|
when do you pull a trench?
|
Should be pre cut with inspection holes on the fire side of the cut. If fire makes it to the inspection cuts then the trench is pulled
|
|
how far away from initial vent hole should trench be cut?
|
20ft
|
|
fire escape in the throat of a building tells us what?
|
2 separate appts in the throat
|
|
no fire escape in the throat tells us what?
|
Appt has 2 exits into hallway
|