Fog (master and handheld)

100 psi

Solid Bore (handheld)

50 psi

Solid Bore ( master streams)

80 psi

Sprinklers

150 psi

Relay Pumping ( minimum )

20 psi

Standpipe

NP + TPL

Foam ( at eductor)

200 psi

What is the pressure elevation loss/ gain per floor?

5 psi per floor

What is the elevation pressure loss/gain per foot?

0.5 psi per foot ( 0.434 psi )

What is the theoretical coefficient for an 1 1/2 inch line?

24

What is the theoretical coefficient for a 1 3/4 inch line?

15.5

What is the theoretical coefficient for a 2 1/2 inch line?

2

What is the theoretical coefficient for a 3 1/2 inch line with 2 1/2 inch couplings ?

0.8

What is the theoretical coefficient for a 4 inch line?

0.2

What is the theoretical coefficient for a 5 inch line?

0.08

If the compound pressure drops between 0 - 10% what is the amount of available water?

3 times the amount being delivered

If the compound pressure drops between 11 - 15% what is the amount of available water?

2 times the amount being delivered

If the compound pressure drops between 16 - 25% what is the amount of available water?

Same amount as is being delivered

If the compound pressure drops more than 25% what is the amount of available water?

Water is available but is less than is being delivered

What is the appliance loss when flowing 0 - 350 gpm ?

0 psi

What is the appliance loss when flowing 350 - 500 gpm ?

10 psi

What is the appliance loss when flowing over 500 gpm ?

20 - 25 psi

What gpm of a fog nozzle on a 1 1/2 line?

100 gpm ( 95 )

What gpm of a fog nozzle on a 1 3/4 line?

150 gpm

What gpm of a fog nozzle on a 2 1/2 line?

200 gpm

What gpm of a 1 1/8 solid bore on a 2 1/2 line?

266 gpm

What gpm of a 1 1/4 solid bore on a 2 1/2 line?

328 gpm

What gpm of a Blitz Auto Fog on a 2 1/2 line?

500 gpm

What gpm of a 1 3/8 solid master on a 4 inch line?

500