  • Front
  • Back
Number of characters in the date time group
12
What is the Form number for a Report of Survey?
CG-5269
What does the navy define as a power supply?
12V
What is the receive voltage of the WSC-3?
AM-3.5mv FM-3mv
How many channels does the WSC-3 operate on?
7000 Possible channels 20 Preset Channels
What is the life expectancy of the SINS package?
8 years
What type of frequency in terms of absorption is the most harmful?
VHF 30-300MHZ
What type of classification cannot be used on a CASREP?
TOP SECRET
What is the form number of RFI/NRFI and what is the minimum information that needs to be on it?
CG-5236
Stock Number
Equipment Nomenclature
Date of Failure
OPFAC
Brief description of the failure
What is the maximum number of characters in the position field?
30 Characters
In regards to CASREP messages, when does the serial number start over?
YEAR001-999
What is the response time for test equipment return?
30 days
What is the COG code for MTR item?
0C
How many Characters are in the quantity section of a CASREP?
Three
Maximum number of characters in the Plain Language Address
50
What is a SCAT code?
A SCAT (SubCATegory) Code is a four or seven alphanumeric code used to identify a range of measurement parameters by functional category.
Maximum number of characters in the 1PARTS Data Line (DL) of a CASREP
Two
What are the HERO, HERF, & HERP sign types?
1.HERP- Keep Moving
2.HERP- Check w/ Command
3.HERP- RF Burn Hazard
4.HERF
5.HERP- General Warning RF Hazard
6.HERP- Secure
7.HERO- Handling Ordinance
8.HERO- Transmitting during ON/OFF Load
What does a Routine Code mean?
R
Speed of service objective is 6 hours or less.
What does a Priority Code mean?
P
Speed of service objective is 3 hours or less.
What is a Immediate Code mean?
O
Speed of service objective is 30 minutes or less.
What is a CASREP Flash Code mean?
Z
Speed of service objective is less than 10 minutes.
What is the power out of a WSC-3 in AM?
30 Watts
Who is responsible for keeping survey logs?
Unit retains report of survey logs for 3 years.
ISC
Commandant (CG-842) (depending on final approval authority)
When requesting assistance in a CASREP who is not an option?
ELC
What is the code for non-repairable items?
C
What is the response time for test equipment return?
30 days
Maximum number of characters in the Plain Language Address
50
Maximum number of characters in the 1PARTS Data Line (DL) of a CASREP
Two
Who is your contact for repairable items?
ELC/SFLC
What is the designator for a part ID in a CASREP?
EIC (Equipment Identification Code)
What priority of a CASREP that affects secondary missions?
2
What priority of a CASREP causes a major degradation but not loss of a primary missions?
3
When would you write a CASCAN?
Within 48hrs.
If equipment is scheduled to be repaired during scheduled maintenance period.
If equipment is replaced with a new type of equipment.
What form number is for a surf log and what Sources of Supply (SOS)?
CG-4940
Prison (UNICOR), NIB-NISH, JWOD, GSA, DLA, the Department of Veterans Affairs, Mandatory Federal Supply Schedules, and Optional-use Federal Supply Schedules
What is the frequency range of a WSC-3?
225.0-399.975Mhz
What form to transfer test equipment to DRMO?
DD-1347
Which version of the WSC-3 is LOS?
Version 6 & 7
Who is responsible for the unit test equipment calibration?
NAVSEA
What is the code for MTR items that are not authorized for repair below Depot level?
R
What is the code for MTR items that are not authorized for repair below intermediate/district level?
H
What charting system is used by both the Navy and Coast Guard?
COMDAC INS Command display and control integrated nav segment
What frequency band is the DGPS operating at?
MF
What is the form for destroyed/ lost electronic equipment?
Report of Survey
CG-5269
Allowance change requests to units SPETREL goes to whom?
CGETEP
After SPETREL Validation how often will notifications be sent?
30 days prior to the first equipment due date.
What does MILSTRIP stand for?
Military Standard Requisitioning & Issue Procedures
How many charecters are in the CASREP TYPE of Casualty-Serial Number?
15
Not the Message Serial# which has 3
How many charecters are in the Message ID Serial # field of a CASREP?
-3
How many charecters are in the Message type field of a CASREP?
-10
How many charecters are in the DTG (Date Time Group) field of a CASREP?
-12
How many charecters are in the Position field of a CASREP?
-30
What is HERF, HERO, HERP sign type 1?
1.HERP- Keep Moving
What is HERF, HERO, HERP sign type 2?
2.HERP- Check w/ Command
What is HERF, HERO, HERP sign type 3?
3.HERP- RF Burn Hazard
What is HERF, HERO, HERP sign type 4?
4.HERF
What is HERF, HERO, HERP sign type 5?
5.HERP- General Warning RF Hazard
What is HERF, HERO, HERP sign type 6?
6.HERP- Secure
What is HERF, HERO, HERP sign type 7?
7.HERO- Handling Ordinance
What is HERF, HERO, HERP sign type 8?
8.HERO- Transmitting during ON/OFF Load
What form must be submitted to ELC in order to change your allowance after a Configuration change?
OPNAV 4790C/K
What are the Four Security classification designators?
UNCLAS, CONFIDENTIAL, SECRET, and TOP SECRET
What identifies the time interval between completions, or the frequency of completion of a maintenance requirement?
periodicity code
How often you send out a CAS-UPDATE for an open CASREP message?
30 days
What are CASREP types of assistance for assistance required field?
none,
depot
technical
other
How often should Antennas and transmission lines be tested/inspected on a floating unit?
monthly
What Occupational Safety and Health Programs for Federal Employees, requires Coast Guard to maintain a safety and occupational health program IAW the Occupational Safety and Health Act of 1970 for civilian employees under the Occupational Safety and Health Administration (OSHA)?
Executive Order 12196
What charting system uses NavSailor as its software?
Transas
Which type of electronic charting system is used on 87’ and 110’ WPBs?
Transas
Where can you find the technical manual for the WSC-3 transceiver?
SFLCs website
Which of the following electronic charting systems (ECS) uses the 5200 CPU?
ECPINS
On what platform is the Gulfcoast Sparcstar/Sunfire Workstation used on?
210’
Which radar system does the SINS replace?
AN/SPS-69
Which radar does the AN/SPS-73 replace?
AN/SPS-64
What are the requisition methods (in order of priority)
1)Configuration Management Plus
2) Mandatory Turn-in Repairable (MTR)/Depot-Level Repairable (DLR)
3) Excess materials from the Coast Guard and other government agencies (DRMO)
4) Military Standard Requisitioning and Issue Procedures (MILSTRIP)
5) Direct Purchase from a commercial source
What does FOUO in a CASREP mean?
For Official Use Only
What does EFTO in a CASREP mean?
Encrypted for Transmission only
What does MICA in CASREP mean?
Management Information for Configuration and Allowance
73 Radar:
Which slot is the Power PC in?
1
73 Radar:
Which slot is the PCMCIA CCA in?
3
73 Radar:
Which slot is the Barco Graphics Card in
4
73 Radar:
Which slot is the NSIU Card in?
9
73 Radar
Which slots are the RSC Cards in?
10 and 11
73 Radar
Which slot is the RDE Card in?
12
73 Radar
Which slot is the RCC Card in?
14
73 Radar
Which slot is the NSIU Distribution Card in?
21
73 Radar
Which Card slots are empty?
5-8
13
16-20
Slot 2 has the Air Deflector Card
How many pounds of pressure does it take to insert a CCA into the VME cage?
30
What is a Navy supported item with a COG code beginning with 7?
DLR
On a DLR item when is the Net price paid?
when carcass is turned in, unit price is paid
On a DLR item when is the unit price paid?
when there is no turn in.
In regards to Direct Purchase what does FAR stand for? What is it?
Federal Acquisition Regulations
guidance on procurement
What is a SPETERL?
Ship/Shore Portable Electrical/Electronic Test Equipment Requirements Listingallowance document that lists the complete systems (not subsystems) and the test equipment required for that system.
How does the Test Equipment Program Office determine whether or not to put a test equipment item on the SPETERL?
The test equipment is for a system that is listed in the CGPMS
When is a CASREP written?
within 24 hours if it reduces mission abilities, cannot be corrected in 48 hours, outside assistance is needed. (note: individual units may require within 4 hours, check SOP)
What is the max charecters in Description of Equipment Section in a CASREP?
24 characters
What is the max charecters in the Amplification (AMPN) section of a CASREP?
max of 10 lines
In a CASREP how many charecter are allowed in the "APL number"
12
In a CASREP how many charecter are allowed in the "Component Identification number"?
12
In a CASREP how many charecter are allowed in the "MICA/COSAL allowance"?
3
When filling out a Configuration Change Form, what blocks should units fill in, as a minimum?
1 – 7, 13 – 23, and signature blocks, work center supervisor
What are the 3 maintenance schedules for CGPMS?
Quarterly
Weekly
Cycle
In regards to PMS what are?:
LOEP
MIP
MRC
List of effective pages=NAVSEA/Navy PMS
Maintenance Index Pages = PMS reference document for each equipment/system, index of MRCs
Maintenance Requirement Cards=procedures for maintenance requirements
What forms must a DLR/MTR item have with it when shipped? When must it be shipped?
Navy=DD 1577-2, DD 1577-3, or Caution Tags and BC1 (DD 1348-1)
Coast Guard= CG-5236

within 48 hours of receipt of replacement item
What are the 4 major phases of a TCTO?
Concept
Validation
Development
Deployment
What size are radhaz signs?
4 or 12 inch
.0004 inch thick
The Product Line Engineering Branch shall further develop the draft TCTO package addressing ____ elements of logistics.
10
a. Design interface
b. Maintenance planning
c. Manpower and personnel
d. Supply support
e. Support equipment
f. Technical data (to include drawings and manuals etc.)
g. Training and Training Support
h. Computer Resources Support
i. Packaging, Handling, Storage and Transportation (PHS&T)