Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
81 Cards in this Set
- Front
- Back
What does Essential AC bus relay No. 1 do when its energized?
|
Connects power from Bus A to MEAC bus.
|
|
What does the Essential AC bus relay No. 1 do when its de-energized?
|
Connects the essential AC bus monitoring relay to MEAC bus
|
|
How can the normally energized Essential AC bus relay No. 1 be de-energized?
|
By placing ESS BUS monitoring switch to OFF.
|
|
What does the Essential AC bus monitoring relay do when energized?
|
Connects power from RAR circuit to essential AC bus relay No. 1
|
|
How can the normally energized Essential AC bus monitoring relay be de-energized?
|
By placing ESS BUS monitoring switch OFF
|
|
What does Essential AC bus relay No. 2 do when energized?
|
Connects power from RAR circuit to FEAC
|
|
What does Essential AC bus relay No. 2 do when de-energized?
|
Connects Bus A to FEAC
|
|
What buses are located in the Forward Load Center Circuit Breaker Panel (FWD)?
|
1. MEAC Bus
2. EXT MDC Bus 3. APU ESS bus 4. MEDC Bus |
|
What buses are located in the Forward Load Center Circuit Breaker Panel (AFT)?
|
1. SEAC bus
2. SEDC bus 3. GOB 4. 28VAC Forward Lighting Bus XFMR 5. 26VAC Instrument Bus XFMR No. 1 6. 26VAC Instrumen Bus XFMR No. 2 |
|
What buses are located in the Forward Load Center Lower Circuit Breaker?
|
1. FEAC Bus
2. FEDC Bus 3. MEDC Bus 4. Essential DC bus feeders 5. MEAC Bus Feeders 6. No Name |
|
What buses are located in the Main Load Center Circuit Breaker Panel?
|
1. Main DC Bus
2. Main AC Bus A 3. Main AC Bus B 4. 28VAC Aft Lighting Bus XFMR |
|
What are the bus priorities for FEAC?
|
Gen 2
External Power Gen 4 APU Gen 3 Bus A |
|
What is the bus priorities for MEAC?
|
Bus A
Gen 2 External Power Gen 4 APU Gen 3 |
|
What is the bus priorities for SEAC?
|
MEAC
SEDC via Inverter |
|
What is the bus priorities for Bus A?
|
Gen 2
External Power Gen 4 APU Gen 3 |
|
What is the bus priorities for Bus B?
|
Gen 3
External Power Gen 4 APU Gen 2 |
|
What is Main DC's normal and alternate Power source?
|
TR No. 1 and TR No. 2 operating in parallel
|
|
What is EXT Main DC's normal and alternate power source?
|
Normal - Main DC
Alternate - No alternate |
|
What does MEDC (SAM) feeders power?
|
Feeder 3 - SEDC
Feeder 1 - armament Feeder 2 - MEDC (electric) |
|
What is MEDC (SAM) normal and alternate power source?
|
Normal - TR No. 3
Alternate - EMDC bus through power - blocking diode No. 1 |
|
What is MEDC's (electrical) normal and alternate power source?
|
Normal - MEDC (sam)
Alternate - No alternate |
|
What is FEDC's normal and alternate power source?
|
Normal - MEDC through power - blocking diode No. 2
Alternate - aircraft battery |
|
Is their any way to secure FEDC?
|
No, it does not have a feeder circuit breaker
|
|
What is the normal and alternate power source for GOB?
|
FEDC though de-energized GOB relay
Alternate - No Alternate |
|
What is the normal and alternate power source for APU ESS?
|
Normal - MEDC (electic) through energized MEDC (electric) powe sensing relay.
Alternate - GOB throught de-eergized MEDC bus (electric) power sensing relay. |
|
What is the normal and alternate power source for SEDC?
|
Normal - MEDC (Feeder 3) bus through de-energized inverter powerer relay
Alternate - FEDC bus through energized inverter power relay. |
|
What are the 5 possible malfunctions if the External power available light ON is on but there isno power into the aircraft?
|
1. Wrong Phase, frequency, or voltage
2. Nosegear uplock not properly positioned 3. Battery not connected 4. Generator No. 4 RAR feeder circuit Breaker out 5. External power control circuit breaker out |
|
What are the possible malfunctions if the FEAC bus is the only one energized?
|
1. MEAC ganged CB out
2. ESS Bus monitoring switch OFF |
|
What is the possible malfunction if the MEAC, SEAC, and FEAC buses are energized, but MEDC, BUS A, and BUS B are not?
|
TR 3 circuit breaker out
|
|
What has similair effects as TR 3 circuit breaker out except that elctronic and armament power will be available through DC feeder #1 adn SEDC bus will be available through DC feeder #3?
|
Essential DC bus feeder circuit breaker No. 2 out.
|
|
What are the 3 different models of APU?
|
GTCP95-2
GTCP95-3 GTCP95-10 |
|
What is the purpose of the APU?
|
To provide pnuematic and electrical power necessary to make the aircraft self sufficient.
|
|
True / False
Bleed air from the APU is available in flight |
FALSE
APU bleed air in not available in flight |
|
What does the APU provide?
|
Electrical
Bomb bay heating Aircraft A/C Main Engine Starting |
|
What are the Intake and Exhaust doors Power Source?
|
APU essential DC bus
|
|
What are the 2 main sections of the APU?
|
Accessory Section
Compressor and Turbine Section |
|
True / False
Ground AC and engine starting CANNOT be used simultaneously |
True
|
|
True / False
Ground AC and bomb bay heat CAN be used simultaneously |
True
|
|
What type of turbine is on the APU?
|
Single stage radial inward flow turbine
|
|
When does the oil pressure sequence switch close?
|
approx 10% RPM with positive oil pressure
|
|
At what RPM is the starter motor de-energized?
|
35%
|
|
At what RPM does the igniton de-energize, read-to-load circuitry energizes and hour meter/start counters start?
|
95%
|
|
Which APU's have start hour meters and start counters?
|
-2 has starts hour meter
-3 and -10 has start counter |
|
When does overspeed protection kick in?
|
106%
|
|
What are the power sources for the starter motor?
|
If MEDC is available through EMDC
If MEDC is not available through FEDC |
|
How much fuel an hour does the APU consume during nomal operating condiitons with the AC on?
|
300 pounds per hour
|
|
Where is the normal fuel supply?
|
Wing Tank #2 but can also be supplied by Wing tanks 1, 3, and 4 by crossfeed system
|
|
Where is the manual fuel shut-off valve located?
|
Port Flap Well
|
|
What is the purpose of the load control and pneumatic system?
|
control amount of air which may be bled from the compressor
|
|
What is Load Control Valve power source?
|
GOB though APU 95% switch
|
|
What is the APU oil tank capacity?
|
1.0 gallon
|
|
When does the APU oil tank require servicing?
|
when oil level is @ or below half mark on lower sight gauge
|
|
What are the 2 oil types?
|
Primary - MIL-PRF-23699
Alternate - MIL-PRF-7808 |
|
What is the temp limits on MIL-PRF-23699?
|
-40*C - 54*C
|
|
What is the temp limits on MIL-PRF-7808?
|
-54*C - 54*C
|
|
What does the tachometer indicate?
|
Gas turbine engine speeds in percent RPM
|
|
Where does the tachometer receive its input from?
|
APU Tachometer Generator
|
|
Where does the Exhaust Gas Temperature (EGT) receive its input from?
|
APU Exhaust thermocouples
|
|
How long will the APU doors closing delay after "OFF" is selected?
|
1 min
|
|
What does the "ARM" position allow on the INFLIGHT ARMING switch?
|
Allows APU to be operated in flight
|
|
What is the power source for the signal lights?
|
APU essential
|
|
When does the (fire) Detection System actuate?
|
when temperature of 400*F is exceeded
|
|
Where is the extinguishing system located?
|
Nose wheel well
|
|
What extinguishing agent is used in the High Rate Discharge (HRD) container?
|
Bromotrifluoro mehtane
CF BR 3 |
|
What is the expelling agent used in the extinguishing system?
|
Dry Nitrogen
600psi @70*F |
|
What is the power source for The Extinguishing System?
|
APU Essention
|
|
Where is the APU fire warning and extinguisher panel located?
|
copilot center glare shield
|
|
Where are the APU fire warning horns located?
|
Flight station and Cabin
|
|
What is the power source for APU Fire detection TEST switch?
|
APU Essential
|
|
What happens when "SAFE" is selected on the APU and Fire Extinguishing Safety Switch?
|
1.Intake and exhaust doors can not be moved
2. APU cannot be started, if APU running it shuts down 3. Deactivates fire extinguishing system, but fire detection is still operative |
|
How long until extinguishing agent will automatically discharge if exhaust doors fail to close?
|
20 sec
|
|
What is the maximum altitude for APU operation?
|
20,000 ft
|
|
What is the maximum altitude for using the APU as a bleed air source for main engine starting?
|
6,000 ft field elevations
|
|
What is max continuous, max for 10 sec, and max peak for GTCP95 - 2?
|
688*C
710*C 715*C |
|
What is max continuous, max for 10 sec, and max peak for GTCP95 - 3?
|
649*C
N/A 704*C |
|
What is max continuous, max for 10 sec, and max peak for GTCP95 - 10?
|
649*C
710*C 732*C |
|
What is the APU ground RPM range?
|
98-102%
|
|
What is the APU Flight RPM range?
|
98-103%
|
|
What is APU over speed?
|
106%
|
|
What is the max airspeed with doors open?
|
225 knts
|
|
What is the purpose of load monitoring?
|
Reduces or secures certain electrical loads during single generator operation.
|