- Front
- Back
Transformer (single phase) |
Use to change voltage,current,phase,and other electrical characteristic. |
|
Surge arrester |
A protective device that limits surge currents through electrical equipment. |
|
|
Transformer(3 phase) |
|
|
Utility box (pvc) |
|
Voltage regulator |
An automatic electrical control device whose output provides a constant voltage supply. |
|
|
High velocity low speed fan (HVLS) |
|
Rectifier |
Is an electrical device composed of one or more diodes that convert AC to DC |
|
|
Pull box |
|
|
Meter box |
|
|
Meter base |
|
|
(NFDS) non-fussible disconnecting switch |
|
|
Junction box (pvc) |
|
|
Utility box (metal) |
|
|
Conduit screw coupling |
|
Lighting outlet |
Is an outlet intended for direct connection to lamp receptacle,lighting ficture, or pendabt chord in a lamp holder |
|
|
Rotary switch |
|
Wall plates |
Are single gang, two gang and three gang. |
|
Plug fuse |
Screw into sockets much like a lamp |
|
Cartridge fuse |
Fuse - is an overcurrent protective device that consist of a strip of metal with a low melting strip. May be one time use or renewable. |
|
|
Junction box (metal) |
|
Circuit breaker (bolt -on) |
Is an over-current protective device that serves two purpose, its acts as a switch that can be opened and closed manually and it automatically trips off. |
|
|
Circuit breaker (plug in) |
|
|
Toggle switch |
|
|
Slide switch |
|
|
Push button switch |
|
|
Liquid immersed transformer |
|
Armored cables |
A fabricated assembly of insulated conductors enclosed in flexible metal sheath. Also known by trade name BX cable |
|
Metal clad cables |
A factory assembled cable of one or more conductors each individually insulated and enclosed in a metalic sheath of interlocking tape of a smooth corrugated tube. |
|
|
Dry type transformer |
|
|
Ceiling raceway |
|
Receptacle outlet |
Is a power outlet where one or more receptacles are installed. |
|
|
Floor raceway |
|
|
Megger |
|
Two types or wire |
Stranded Solid |
|
UPS stands for? |
Uninterupted Power Supply |
|
Cat 7, SSTP, GG45 connector |
Gg45 connector |
|
TPC, RJ11 connector |
Rj11 connector |
|
Coaxial cable, BNC, RJ6 connector, |
RJ6 |
|
Cat5,Utp, RJ45 connector, |
Rj45 connector |
|
Cat6, stp, Rj45 connector |
Rj45 connector |
|
Smoke detector |
Smoke detector |
|
Heat detector |
Heat detector |
|
Flame detector |
Flame detecror |
|
Manual pull station |
Manual pull station |
|
Merchandise anti thef |
Merchandise anti thef |
|
Modem |
Modem |
|
Router |
Router |
|
Wifi booster |
Wifi booster |
|
Intermidiate metal conduit- IMC |
Thickness 0.071 3m length |
|
Rigid steel conduit RSC |
Heavy wall conduit. Thickness 0.117 Standard for service entrance 3m length. |
|
Electric metal conduit EMT |
Thin wall conduit Can be offset 3m length |
|
Condulet |
common Fitting use for RSC and IMC. |
|
Conduit screw coupling |