How is the electrical system managed when a fault occurs?
|
The electrical system monitors itself for faults and automatically disconnects a Generator
bus from its power source when electrical power is out of limits |
|
What is the normal source of power for an AC TRANSFER bus?
|
Respective GEN bus
|
|
CONDITIONS: Both engine driven generators on line; APU shut down; BUS TRANSFER switch
in the AUTO position. Which buses are not powered if # 2 engine driven generator trips off? |
Generator bus and Main bus on failed side
|
|
What is the power source for TR-3?
|
Main Bus #2
|
|
What is the normal source of power for TRs 1 and 2?
|
Respective AC TRANSFER buses
|
|
What is the "backup" source of power for DC Bus 1?
|
#2 TR
|
|
How does the TR 3 disconnect relay normally function?
|
Automatically opens during an A/P or FD approach at glide slope capture
|
|
What is the power source for the Hot Battery bus when all aircraft buses are powered?
|
Battery charger
|
|
What is the normal source of power for the AC Ground Service bus?
|
#1 Generator Bus
|
|
What is the normal source of power for the Battery bus?
|
TR 3
|
|
What is the normal source of power for the Battery Charger?
|
AC GRND SERVICE bus
|
|
The aircraft is in flight with only the battery for electric power. Where does the power come from
for the AC and DC Standby buses? |
Static Inverter for the AC Standby bus, and Battery bus for the DC Standby bus
|
|
What is the alternate power source for the Battery bus?
|
Hot Battery bus
|
|
What is the alternate source of power for the Hot Battery bus when the normal power source is
not available |
Battery
|
|
What is the alternate power source for the Battery Charger
|
Main Bus 2
|
|
What is the purpose of the CSD?
|
Change variable engine speed into constant generator drive speed
|
|
Which DC Selector positions display DC amps?
|
TR's 1,2,3, and BAT
|
|
Which of the following must be accomplished to check the battery condition?
|
Turn on the battery switch, place DC meter selector to BAT, check volts within limits
|
|
How is a failure of TR 1 indicated with the TR 3 disconnect relay closed?
|
0 amps, normal volts indicated on the DC meters at the TR 1 position
|
|
How would a failure of the static inverter be indicated during the standby power check?
|
0 volts on the AC volt meter, and 0 cps on the AC frequency meter
|
|
What is the function of the ON position of the galley power switch?
|
Powers all galleys when both Generator buses are powered
|
|
With the battery switch ON, which statement is correct?
|
Both the Battery bus and Switched Hot Battery bus are powered
|
|
Which statement describes establishing power to the Ground Service Bus on the ground?
|
GRD POWER AVAILABLE light on, GROUND SERVICE switch on
|
|
What does an illuminated STANDBY PWR OFF light indicate?
|
The AC Standby bus is unpowered
|
|
What is the function of the AUTO position of the STANDBY POWER switch with loss of all AC
power? |
Allows the BATTERY BUS to be the source of power for both Standby buses inflight
|
|
What does an illuminated CSD HIGH OIL TEMP light indicate?
|
CSD oil temperature exceeds operating limits
|
|
Which is correct for disconnecting a CSD?
|
Hold generator drive disconnect switch to DISCONNECT momentarily. The CSD may reengaged
on the ground by maintenance |
|
What does an illuminated GRD POWER AVAILABLE light indicate?
|
Ground cart is plugged in and external bus is powered
|
|
What is the function of the ON position of the GRD PWR switch?
|
Connects ground power to both Generator buses if the ground power quality is correct
|
|
What is the function of the OFF position of the BUS TRANSFER switch?
|
Prevents operation of bus transfer relays, prevents battery charger from switching to
Main Bus 2, and opens TR 3 disconnect relay |
|
What does an illuminated BUS OFF amber light indicate ?
|
The respective Generator bus is unpowered
|
|
What does an illuminated TRANSFER BUS OFF light indicate?
|
Respective Transfer bus is unpowered
|
|
What is the function of the APU Generator switches?
|
Connects generator output to Generator bus if power quality is correct
|
|
In flight, the AC Ground Service bus is powered by:
|
Generator Bus 1
|
|
Engine driven generator maximum load is
|
125 Amps
|
|
In the air, galley power is available only when both generator buses are powered
|
TRUE
|
|
All power sources to a GEN BUS must be manually connected through the movement of a
switch |
True
|
|
What are the Transformer Rectifier operating parameters?
|
24-30 volts
|
|
With a loss of all generators, a fully charged battery can supply power to the standby buses for
at least |
30 minutes
|
|
On the ground, alternate power for the Standby buses requires
|
Standby power switch at BAT
|
|
With loss of normal AC power in flight, power for the Standby AC and Standby DC buses is
automatically available from: |
Battery bus and Static inverter
|
|
A ground service bus control switch, labeled "GROUND SERVICE" is located on the
|
Forward flight attendant panel
|
|
An amber "BUS OFF" light is:
|
Extinguished when the corresponding GEN bus is powered
|
|
What is the maximum engine generator electrical load limit?
|
125 amps
|
|
What is the minimum battery voltage for an APU start?
|
23 volts
|
|
When a CSD LOW OIL PRESSURE or HIGH OIL TEMP light comes on, the system annunciator
and Master Caution lights illuminate |
ELEC
|
|
The __________ light is illuminated when the External AC Bus is powered
|
GRD POWER AVAILABLE
|
|
What is the basic AC power distribution? (300/500)
|
AC power source to the GEN BUS, GEN BUS supplies its respective MAIN AC BUS and
TRANSFER AC BUS |
|
The DRIVE light for an IDG illuminates when (700/800/900)?
|
All Answers are correct
|
|
What is the maximum single engine drive generator load for an 800 model aircraft on the ground?
|
215 Amps
|
|
When a B737-700 model IDG is operating and the IDG breaker is closed, the IDG output is
connected to |
An AC Transfer Bus
|