On a GFCI receptacle, the incoming power is connected to the line terminals

True

_____ are considered non-temperable and are used in new installations requiring fuses.

Type S

Schedule 40 nonmetallic conduit has a smaller outside diameter then schedule 80 rigid nonmetallic conduit

False

One a receptacle, the brass screw is used to terminate the ground conductor

False

The ____ is a scale of specified diameters and cross sections for wire sizing and is the standard wire sizing scale for the United States

American wire gauge

_____ The most often used type of over current protection device used in residential wiring

Circuit breakers

A low resistance path, which results in a high value of current that flows around, rather than through, a circuit is called a _____ circuit

Short

Which of the following switches has ON/OFF marked on the switch handle?

Double-pole

The ____ is an organization that develops electrical equipment standards that all member groups follow when designing and producing electrical equipment.

National Electrical Manufacturers Association

A switch that is used on 240-Volt circuits to control a load from one location is called a ____

Double-pole

When nonmetallic device boxes that are 2- gang or more are used, the installed cable must be supported within _____ inches of the box

12

CO/ALR marked on a receptacle indicates that ___ conductors may be terminated to it.

Copper


Copper-clad Aluminum


Aluminum

The following conductors is the largest?

#8 AWG

#8 AWG


#10 AWG


#12 AWG


#14 AWG

The NEC requires that rigid metallic conduit to be supported within ___ feet of each box and then no more than every ____ feet thereafter

3,10

3,8


5,10


2,10


3,10

The Grounded conductor is terminated to the ___ terminal on a receptacle

Silver

Type ____ cable is used for underground installations of branch and feeder systems

None of the above

NM


NM-B


SE


None of the above

Type ____ cable is a three-conductor cable used for underground service entry installation

USE

The ____ Conductor is used as the grounded conductor and returns Current from the load back to the source

White

When using aluminum conductors, _____ size conductor must be used to carry the same amount of current as a copper conductor

A larger

The National Electric Code requires electric cable supported within _____ Inches on single-gang nonmetallic device boxes

8

It is the _____ who has the job of approving the electrical materials

Authority Having Jurisdiction

And accidental connection of a “hot” conductor and a grounded piece of equipment or the grounded conductor is called a ____

Ground fault

All ____ boxes must be accessible after they are installed.

Junction

Electricians usually referred to armored clad cable as _____ cable

Bx

A _____ Is an overcurrent device that opens a circuit when a fusible link is melted away by the extreme heat caused by an overcurrent.

Fuse

____ Devices are used when more than one device is needed at one location

Combination

_____ Fuses cannot be used in new installations.

Edison

A (n)_____ Is a point on the wiring system at which current is taken to supply equipment.

Outlet

_____ Is a measure of how much a fastener is being tightened and is measured in foot-pounds

Torque

The _____ Of a conductor refers to it ability to Carry Current

Amps

A ____ Made from non-conductive nylon or stainless steel, is used to pull wires or cables through electrical conduit

Fish Tape

A(n)_____ is usually 9Long and is used to level or plumb conduit, equipment, and appliances.

Torpedo

A (n)_____ Is used to pull wires or cables through conduit and to pull cables in insulated walls

Lines man Pliers

A (n)_____ Used to cut holes in wall board for boxes and to put plaster and lath for box installation in remodeling work

Keyhole saw

______ Screwdrivers are used to remove and install screws limited working space and to tighten and loosen lugs in limited working space.

Stubby

_____ Used to cut cables, conductors, form large conductors, and to pull and hold conductors.

Lineman Pliers

_____are used to form small conductors, cut conductors, and to hold and pull conductors.

Long-nosed pliers

_____ are used to cut cables and conducters in a limited space.

Diagonal pliers

_____ Are used to strip insulation, crimp solderless connectors, cut and size conductors, and cut and thread small bolts.

Multipurpose tool

A _____ Is used to transfer location points from ceiling to floor and floor to ceiling and to plumb conduit equipment

Plumb Bob

Of the following is not a commonly used drill chuck size

3/8

1/8”


1/4”


3/8”


1/2”

Probably the most popular style of wire stripper used in residential wiring is the non-adjustable type, commonly called a (n)_____

T-stripper

If a run of conduit is plumb, It is _____ to the floor.

Perpendicular

When using a sledgehammer to install a ground rod at least _____ feet of the rod must be in the ground

8 Feet

On Construction sites, all 125-volt power tools must be plugged into a(n)_____

GFCI

To drill holes in the studs electricians generally use a _____ drill to make Drilling easier in the tight spaces between framing members.

Right Angle

_____ drills are used to drill holes in masonry or concrete walls and floors.

Hammer

Another name for a Skil saw is a _____ saw.

Circular saw

Another name for a “Sawzall” is a _____ saw.

Reciprocating saw

A _____ Is used to cut holes in metal boxes for installing cable or conduit

Knockout punch

An electricians Hammer has _____ claws .

Long/straight

A drill bit with a spiral cutting edge used to bore holes in wood is called a(n) _____ bit.

Auger