Hyd Combined System Total
14 gal
Hyd Combined Reservoir
3.3 gal
Hyd Flight System Total
5.8 gal
Hyd Flight Reservoir
1.3 gal
Hyd System Px
3000 psi
Combined Accumulator Px
2000 +/- 100 psi
Flight Accumulator Px
2000 +/- 100 psi
Px Relief Valve Closes at:
3785 psi
Hyd Comb Level Light
2.1 gal remaining
Hyd Flight Level Light
1.0 gal remaining
Ldg Gear Accumulator Px
3000 +/- 150 psi
Gear Extends in _______ and retracts in ________?
Extends in 15 sec and Retracts in 10 sec
Emergency Brake Accumulator Px

(Bonus: Preflight Check)
800 +/- 50 psi

(Checked Full on Preflight)
Rudder Stop @ <140 KIAS
20 deg
Rudder Stop @ 140-220 KIAS
6 deg
Rudder Stop @ >220 KIAS
2 deg
Arresting Hook Dashpot Px
360 +/- 10 psi
Hyd Filters Pop at:
70 +/- 10 psi
Hyd Filters Bypass at:
100 +/- 10 psi
Oil Tank:
10 Liters
Auto Preheat/Cool Time Out, Temp, & Px (E-2C+)
8 min
48-65 deg F

10.5-15.0" H2O
Direct Cool Time Out, Temp & Px (E-2C+)
5 min 20 sec
48-65 deg F

10.5-15.0" H2O
Direct Heat Time Out, Temp & Px (E-2C+)
10 minutes minimum

30 min recommended
65-90 deg F

>10.5" H2O
Auto Preheat/Cool Time Out, Temp, & Px (HE2K)
6 min 34 sec
48 - 69 deg F

13.0-20.0" H2O
Direct Cool Time Out, Temp, & Px (HE2K)
2 min 04 sec
48 - 69 deg F

13.0-20.0" H2O
Direct Heat Time Out, Temp, & Px (HE2K)
10 minutes minimum

30 min recommended
65 - 90 deg F

>13.0" H2O
Vapor Cycle System Fault
(E-2C+)
Temp >65 deg F in Cool

Temp <65 deg F in Heat
Px <10.0" H2O
Vapor Cycle System Fault
(HE2K)
Temp >69 deg F in Cool

Temp <65 deg F in Heat
Px <13.0" H2O
Vapor Cycle Cond Temp Fault
Temp at Condenser Inlet
>110 deg F
Vapor Cycle WRA Fault Repair Time for DS1 and DS5
5 minutes and 20 minutes
ARC-182 Frequency Range
30 - 399.975 MHz
ARC-158 Frequency Range
225 - 399.975 MHz
ARQ-34 Frequency Range
2.0 - 29.999 MHz
0 - 5000' MSL Cabin Altitude
Ambient
5000' - 35000' MSL Cabin Altitude
5000' Px Alt
Above 35000' MSL Cabin Altitude
Px Differential of 8.8 psi
Oxygen System Capacity and Pressurization
10 L at 55 - 110 psi
O2 Light illuminates at
< 1.0 liter or < 50 psi
Crew Emergency Bottle Pressure and Capacity (Time)
1800 psig ; 5 - 7 minutes
Walkaround Bottle Pressure and Capacity (Time)
1600 psig ; 20 minutes
Cabin Px Light illuminates at:
7500' Cabin Alt
Cabin Dump when pressure differential is:
> 9.5 psi