IDG stands for:
Integrated Drive Generator
Each IDG consists of:
Generater,
Constant Speed Drive
Drive oil system
Generator control switches have what positions:
On
and
Off
The generator control switch ON position does what:
Closes the
associated generator field
and
arms
the generator breaker to close or open automatically
The generator control switch OFF position does what:
Opens
the associated generator field and breaker

EICAS message LorR GEN OFF
How is an automatic trip of the generator breaker indicated:
Appearance of both
the ON flow bar and
the GEN CONT OFF light with an EICAS
when on the GEN CONT SW appears both
the ON flow bar and
the GEN CONT OFF light with an EICAS
2 things are possible:
A trip due to a fault or
it is selected off.
GEN DRIVE DISC sw
disconnects what from what:
It disconnects the generator from the engine
What light will appear in the
GEN DRIVE DISC sw
during a fault:
DRIVE
What does a DRIVE light indicate in the GEN DRIVE DISC sw
oil pressure too low
or
oil temperature too high
Activating the GEN DRIVE DISC sw
does what:
Opens the associated generator breaker
Disconnects the IDG
APU GEN sw
ON:
Closes APU generator field and arms APU generator breaker for automatic operation
If external power is not in use and APU generator output is normal then:
APU generator breaker closes
If a fault occurs the APU generator breaker:
opens
APU GEN sw
OFF:
Opens APU generator field and APU generator breaker, and resets fault trip circuitry
with the left generator not operating, the APU generator breaker will:
close automatically
What condition might be indicated by the presence of both the ON flow bar and the APU GEN OFF light?
The APU generator breaker is open as a result of a fault
EXT PWR AVAIL light indicates
acceptable external power is plugged into the receptacle
When acceptable external power is plugged into the receptacle and the switch is positioned on what happens:
APU and/or engine generator breakers will open
EPC closes
External power connects to both AC buses