How far to set thermocouple or thermopile into pilot flame?

3/8" to 1/2 "

What is purpose of an open-circuit test?

To find the full output of the thermocouple by itself with nothing connected.

What is an acceptable open circuit voltage range?

17 mv to 32 mv

What is the purpose of a closed circuit test?

Is about finding the voltage drop across the power unit( under load)

What is "response time"?

The time it takes the thermocouple to cool down sufficiently to cause the electromagnet on the power unit to de- energize and stop the gas flow.

The response time shall not exceed?

3 min or 180 sec for appliances up to and including 400 000 btu

When installing a new thermocouple, avoid bending the thermocouple too close to either end? What is the measurment?

1/2 "

What temperature would you want the furnace fan to turn on between? And what temp to shut off?

When the temperature reaches between 120°f and 140°f for fan on, and 90°f and 100°f for off