- Front
- Back
What are the entry conditions to DEOP 100?
|
DW > 2#
RPV <8" RPV > 1060# Rx Power > 6% when scram should have occurred |
|
What DEOP(s) are you in with:
DW > 2# ? |
DEOP 100
DEOP 200-1 |
|
What DEOP(s) are you in with:
RPV < 8" ? |
DEOP 100
|
|
What DEOP(s) are you in with:
RPV > 1060# ? |
DEOP 100
|
|
What DEOP(s) are you in with:
Rx Pwr > 6% when a scram should have occurred ? |
DEOP 100
|
|
What are the entry conditions for DEOP 200-1?
|
DW > 2#
DW > 160 degrees (points 5 & 6) Torus > 95 degrees Torus < -4.5" OR > -1.5" Hydrogen > 3.5% |
|
What DEOP(s) are you in with:
DW temp > 160 degrees ? (Bonus: Where do you get the temps?) |
DEOP 200-1
Bonus: TR points 5 & 6 |
|
What DEOP(s) are you in with:
Torus Bulk Temp > 95 degrees ? |
DEOP 200-1
|
|
What DEOP(s) are you in with:
Torus < -4.5" OR > -1.5" ? |
DEOP 200-1
|
|
What DEOP(s) are you in with:
Hydrogen above 3.5% ? |
DEOP 200-1
|
|
What are the entry conditions to DEOP 300-1?
|
Area Temps > Figure (150 degrees)
Area Rad levels > Figure (Ranges 9-50 mR/hr, HPCI 150) Secondary Containment D/P > 0" Vent Radiation > 4mR/hr RBFDS > hi-hi alarm Corner Room water level > 0" |
|
What DEOP(s) are you in with:
Various Rx Bld Area temps are > Figure? (Bonus: What is the temp(s) on the figure?) |
DEOP 300-1
Bonus: 150 degrees |
|
What DEOP(s) are you in with:
Various Rx Bld area rad levels are > Figure? (Bonus: What is the rad level(s) on the figure?) |
DEOP 300-1
Bonus: HPCI (150/100), ISO (10) E CRD/Inst Rack/RWCU (30), W CRD (50), W LPCI (12), E LPCI (9) |
|
What DEOP(s) are you in with:
Secondary Contaiment D/P above 0" ? |
DEOP 300-1
|
|
What DEOP(s) are you in with:
RB Vent radiation > 4 mR/hr ? |
DEOP 300-1
|
|
What DEOP(s) are you in with:
RBFDS > hi-hi level alarm ? |
DEOP 300-1
|
|
What DEOP(s) are you in with:
LPCI corner room water level > 0" ? |
DEOP 300-1
|
|
What are the entry conditions for DEOP 300-2?
|
Off-site release rate above GSEP "Alert" level.
|
|
What DEOP(s) are you in with:
Off-site release rate above GSEP "Alert" level ? |
DEOP 300-2
|