TAC Water Auto Starts:




Test Question

Standby pump auto starts if discharge pressure of operating pump lowers below 155 psig (145 psig) on CPI-600 (on common header).

TACW Pump Trips

Load Conservation


Loadshed


Overload


Overcurrent

What are the TACW System loads?




Test Question

Exciter Coolers


Bus Duct Cooling


Hydrogen Coolers


Stator Water Coolers


Steam Packing Exhauster (U1)


Gland Steam Condenser (U2)

What are the power supplies for the TACW Pumps?

TRAIN B 600 V - Note that a loss of Train B will result in a loss of TACW cooling and an eventual Turbine Trip due to rising Stator Temperatures.

What happens to the TACW inlet valves to the Steam Packing Exhauster/Gland Steam Condenser on an Extreme High Level?

Valves will close.

Closed Cycle

One of two TACW pumps take suction on the common return header and discharge through the TACW Hx.

What are the temperature requirements for being in Closed Cycle?

>95F (U1), >104F (U2)

Open Cycle

TACW pump suction is supplied from the Hotwell Pump Discharge header and pumped through Hx Bypass Valve (CMO-600). Once through loads, water is returned to Hotwell Pump discharge header.

Modified Open

Open cycle with TACW Hx. Used up to 30% power to reduce overall condensate temps.

What are the measured parameters used to ensure TACW is operating correctly?

Temperature & Pressure