These procedures for capping concrete cylinders and cores to meet the standard practice's requirements for...

1) planeness



2) perpendicular

Equipment needed for the capping process includes capping...

1) plates



2) alignment devices



3) melting pot

Plates for neat cement and high-strength gypsum plaster caps should be made of...


1) glass



2) metal or



3) granite

Sulfur mortar cap plates should be formed against...

metal or stone plates BUT no deeper than 12mm

ASTM # for Standard Practice for Capping Cylindrical Concrete Specimens

C617 / C617M - 15

Neat cement caps and high-strengh gypsum-paste caps shall be formed against a GLASS PLATE at least 1) ___ mm thick, a MACHINED METAL PLATE at least 2) ___ mm thick or a POLISHED PLATE OF GRANITE OR DIABASE at least 3) ___ mm thick

1) 6



2) 11



3) 75

In ALL cases of capping, the plates shall be at least ____ greater in diameter than the test specimen.

25mm

The working surface shall not depart from a plane by more than ___ in ___.

0.05mm in 150mm

The capping plates, when new, shall be free of ___, ___ or ___beyond those caused by the finishing operation.

gouges, grooves and indentations

Metal plates that have been in use shall be free of gouges, grooves, and indentations greater than ___ deep or greater than ___ in the surface area.

0.25mm, 30mm

Using a guide bar or bull's eye level, no single cap will depart from perpendicularly to the axis of a cylindrical specimen by more than ___.

0.5°

The location of each guide bar with respect to it's plate must be such that no cap will be off-centered on a test specimen my more than ___.

2mm

The flash point of sulfur is ___.

207°C

If sulfur mortar, high strength gypsum paste and other materials EXCEPT neat cement paste are to be used to test concrete with a strength greater than ___ and the compressive strength is ___ than the cylinder compressive strength.

7000 psi, less

The average strength of 1) ___ capped with the material is not less than 2) ___ of the average strength of 3) ___ companion cylinders capped with 4) ___ or 5) ___ground plane to within 6)___.

1) 15 cylinders



2) 98%



3) 15



4) neat cement paste



5) 0.05mm

The standard deviation of the strengths of the capped cylinders in not greater than ___ times that of the standard deviation of the reference cylinders.

1.57