name 7 qualitites of an ideal disinfectant:
1. broad spectrum-wide antimicrobial spectrum
2. fast acting-rapidly lethal on microorganisms
3. non-toxic-to operator; touch or inhaling
4. surface compatibility-not damaging to equipment and surfaces
5. easy to use-easy to mix or ready to use
6. residual effect-prolonged biocidal activity after application
7. odorless-non-offensive or no odor
Levels of surface disinfectant ?:
commonly used in surgical areas as a disinfectant or sterilant
high-
levels of surface disinfectant: ? unaccepetable in dental office; does not kill many microorganisms; quarternary ammonium compounds. iodophors, complex phenols.
low
levels of surface disinfectant?: commonly used in dental offices; should be EPA registered as tuberculocidal, hospital-grade and viurcidal; ability to kill Mycobacterium tuberculosis; chlorine compounds, iodophors, complex phenols
intermediate level disinfectant
_______: kills most microorganisms
disinfection
_____ ______-minimizes risk of puncture wounds; efficiently removes dried contaminants; can be used to clan dentures in a self-contained container
ultrasonic cleaning
_______: designed to kill all microoranisms, including spores.
sterilization
? method of sterilization: 20 minutes at 121 degree C and 15-30 psi. Variations in cycle depend on whether instruments are packaged and packing material-do not used closed containers, corrosion of non-stainless steel may occur, Bacilus stearothermophilus
steam autoclave
? method of sterilization: 20 min at 132 degree C and 20-40 psi-do not use closed containers, may damage plastic and rubber items, provide adequate ventilation, cannot sterilize liquids, Bacillus stearothermophilus spore test
unsaturated chemical vapor
? method of sterilization: 60-120 min at 160 degree C-cannot sterilize liquids, may damage plastic and rubber items, do not use paper products, recommened for metal instruments. Bacillus subtilis spore test
Dry heat
? method of sterilization: 10-16 hours at 61 degrees C- used for heat sensitive items, long turn-around time, requires adequate ventilation, Bacillus subtilis spore testing
Ethylene Oxide
____ tests- determine if autoclave is reaching proper temperature and pressure to kill all microorganisms
Spore tests
____ _____-turns brown once temperature is reached; does not determine sterility of instruments
indicator tape
____ _____: not present due to being extracted or congenitally missing: congenitally missing teeth are nothing to be concerned with, neeed to make patient aware of them.
Missing teeth
______ ______-have not erupted or are impacted
unerupted teeth
________-spaces between teeth; commonly caused by missing teeth, primate spaces
diastema
______-restores function to area where one or more teeth are missing; homecare of discussed in oral hygiene instructions
bridges
____ ______-restores function to area where one tooth is missing
dental implands
_____ ______-removal of pulpal tissues and replacement with endodontic material
root canal
_____-maxillary and mandibular teeth do not occlude
openbite
_______-maxillary teeth are positioned lingual to the mandibular teeth: commonly need to identify from intraoral photos.
crossbite
______-vertical overlap of maxillary and mandibular incisors; commonly need to identify from intraoral photos; deep overbite may cause indentation of maxillary lingual tissues.
overbite
_______-horizontal overlap of maxillary and mandibular incisors; may use probe to measure amount of overjet.
midline deviation