Under what circumstances can you connect #1AWG (rated at 220A unbundled) to a 400A service?

#1AWG 20 tails from the service to a subsequent 200A over current protection

If a normal show tie-in is a 120/208V, 400A, 3○ land power, and you know the maximum current draw on any given leg durning the show is 143A, what size generator would you spec out of the following?

75kVA

Approximately how much resistance does 1000 of 4/0 have?

0.047

The base line meter test reads 0.4 ohms, the neutral to ground resistance reads 0.6 ohms and reversing the leads shows 0.2 ohms. What is the primary cause or causes, is it okay?

DC voltage leak causing deflection in resistance check, system is okay with neural to ground resistance at safe level

On a branch circuit why will there be some voltage between neutral and ground when equipment is turned on and operating?

Because of the return current on the neutral and the neutral and resistance from the length of the cable

2011 NEC table 400.5(A) (2) states the ampacity of cables. What is the ampacity of 4/0 rated for 90°C at an ambient temperature of 30°C (not bundled)

405A

.SIO file

Crossover file. Or module file

.LIO file

Show file. Contains everything

When closing Clair lake controle soft wear from the menu option "Quit Controller" what type of file is created?

Last config .HIO

If the Clair Lake controller software quits unexpectedly (i.e. computer crashes)...

#1 Autosave .HIO


#2 Autosave .BAK

Which of the following will not mute Auido?

Recall Compare


Recall as new system


Do you want to recall the last system configuration

Steps to replace a frame

Check firmware


Factory rest amp


From home click on the from you want to replace


Click modules


Click copy, frame replace


Click replace frame


Ping amp


Click on frame that shows from amp


Click replace frame


Yes to prompt

What series 2 HI-D fan out make a balanced pair

1&3 2&4

What Cohesion HI-D fan out make a balanced pair

1&2 3&4