How much faster can an expert extinguish a fire with an extinguisher, in comparison to a novice?
2.5x faster
What colors are the symbols for the 5 types of extinguishers?
Class A - green triangle. Class B - Red Square. Class C - Blue circle. Class D - Yellow Star. Class K - no symbol or color
Why is Class K different from Class B?
Newer cooking oils have a higher temperature rating and commercial cookers have a higher insulation value so re-ignition of the grease fire had become a concern.
What is a 1-A extinguisher rated for?
Equivalent to a fire consisting of a wood crib made up of 50 pieces of 5cm x 5cm x 50cm boards is set on fire and allowed to burn for a few minutes. 5L water extinguisher is a 1-A, 10L is 2-A, etc.
What is a 1-B extinguisher rated for?
1 square foot that has an appreciable depth (6mm or greater)
How are Class K extinguishers rated?
They are rated as a minimum of 40-B. In general, they must meet 3 criteria: 1. Completely extinguish the fire in the deep fryer. 2. Prevent re-ignition of the vegetable oil for 20 minutes or reduce the oil temperature at least 15.60C below its auto-ignition temperature. 3. Cause no splashing of flaming oil outside of the fryer.
What rating are dry chem extinguishers and are their discharge time/distance?
20A60BC, 10-25 sec, 2-4.5 meters
What rating are CO2 extinguishers and are their discharge time/distance?
10BC, 10-30 sec, 1-2.5 meters
What rating are Metal X extinguishers and are their discharge time/distance?
No rating, 10-25 sec, 2-4.5 meters
What rating are Back-pack pump extinguishers and are their discharge time/distance?
4A, 60-180 sec, 3-9 meters (20L of water)
What extinguishers on Pump, Tanker and ATP?
Back-pack pump, Dry Chem, CO2
What extinguishers on Rescue?
Dry Chem, CO2, Metal X
What extinguishers on Ladder
Dry Chem and CO2. Note that Quints have Metal X
What size are Metal X extinguisher?
14 kg (used on sodium, sodium/potassium alloys, or magnesium)
With regards to extinguishers, what does REACT stand for?
Rescue/evacuate, Ensure doors are closed, Activate fire alarm and/or notify other occupants, Call 911, Try to extinguish fire.
When inspecting an extinguisher, what should you check?
1. The appropriate extinguisher is in its designated location. 2. The extinguisher is fully charged 3. Examine for broken witness wire or other signs of previous use 4. Signs of tank corrosion or other physical damage 5. Signs of cracking on hoses or obstructions to nozzles. 6. Date of last hydrostatic test of extinguisher shell. 7. Date of last inspection. (note that all EFRS extinguishers are inspected annually by third party)