  • Front
  • Back

The threads of drainage fittings shall be tapped as to allow blank per foot grade

1/4 inch per foot grade 701. 3.2 threads

Does an expansion joint need to be accessible if used in a vent or in a drainage stack

705.8 point to Expansion Joints. No-

What is the minimum thickness for a lead safe pan

7015 lead (1) not less than four pounds per foot or 1/16 of an inch

Fittings used for drainage Shelby of the blank type have a blank blank blank and be so constructed as to allow blank grade

701. 3.3 type. Drainage type have a smooth interior Waterway and be so constructed as to allow 1/4 in of grade.

Define copper alloy

Chapter two definitions a homogeneous mixture of two or more Metals in which copper is the primary components such as brass or bronze

Galvanized pipe can be installed Underground

701.2 drainage piping Section 1 no galvanized rod iron or galvanized steel pipe shall be used underground and kept not less than 6 in above ground