• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/30

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

30 Cards in this Set

  • Front
  • Back
MK16 MOD _____ is primarily used by SPECWAR divers.
0
MK16 MOD _____ is primarily used by EOD divers.
1
The maximum working limit for MK16 MOD 0 is ____ fsw using N2O2 diluent.
150
The maximum working limit for MK16 MOD 0 is ____ fsw using HeO2 diluent.
200
The maximum working limit for MK16 MOD 1 is ____ fsw using N2O2 diluent.
190
The maximum working limit for MK16 MOD 1 is ____ fsw using HeO2 diluent.
300
Four basic systems of the MK16 MOD 0 are housing, recirculation, pneumatics, and ____.
electronics
Inhalation and exhalation hoses, mouthpiece and FFM, co2 canister, and breathing diaphragm comprise the ____ system.
recirculation
The closed-circuit subassembly contains a removable cover, fixed center section, breathing diaphragm, and a ____ scrubber assembly.
co2
The scrubber has two functions: co2 removal, and ____ removal.
water
HP oxygen and diluent bottles, indicators, regulators, fittings, tubing, filters and valves describe the ____ system.
pneumatics
A steady-green light on the primary display indicates a normal ppo2 range of 0.60 ata to ____ ata.
0.90
A ____ green indicates ppo2 above 0.90 ata.
flashing
A ____ red indicates ppo2 below 0.60 ata.
flashing
____ red/green indicates a normal transitioning period, one sensor out of limits, low primary battery power, or primary electronics failure.
Alternating
Maximum descent rate in MK16 is ____ fpm.
60
A certified and ready chamber accessible within 30 minutes of the dive site by transportation is required for dives deeper than ____ fsw.
200
What is the required wait time before flying, if MK 16 MOD 1 no-D dives were conducted for a TBT of 1:54:00?
12 hours
In the event of caustic solution in the diver's mouth, he should first assume a ___ position in the water.

A. horizontal
B. bouyant
C. upright
C. upright
The ____ display provides readouts from the O2 sensors, information on primary battery voltage, and condition of the secondary batteries.
secondary
The secondary display can function as an independent backup to the primary display in case of ____ electronics failure.
primary
Workup dives should be conducted prior to dives exceeding ____ fsw.
130
Prior to making an operational dive, a diver who has not made a MK 16 MOD 0 / MOD 1 dive in the previous six months must:

A. return to dive school or NSWC to complete the necessary qualification course.

B. complete MK16 PQS, and demonstrate predive procedures to re-quality.

C. re-familiarize himself with EPs and OPs, and complete a training dive.

D. be processed for ADSEP
C. re-familiarize himself with EPs and OPs, and complete a training dive.
The endurance of the MK 16 MOD 0 depends on flask floodable volume, initial predive pressure, required reserve pressure, ____ consumption by the diver, and effect of cold water immersion on flask pressure.
oxygen
Depending on rate and depth of descent, the primary display on the MK 16 MOD 1 may indicate a flashing green for 2 to ____ minutes until the ppO2 reaches setpoint level.
5
Depending on rate and depth of descent, the primary display on the MK 16 MOD 0 may indicate a flashing green for 2 to ____ minutes until the ppO2 reaches setpoint level.
15
The MK 16 MOD 1 should transition from 0.7 ata to 1.3 ata mode at____ fsw.
33
If the primary display on the MK16 MOD 1 does not indicate a transition from 0.7 ata to 1.3 ata mode on decent beyond 40 fsw, the following should be performed:

A. maintain depth for 10 minutes, and terminate the dive if no transition is indicated

B. maintain depth for 5 minutes, and terminate the dive if no transition is indicated

C. initiate procedures to perform a screw change

D. terminate the dive with appropriate EPs as necessary
D. terminate the dive with appropriate EPs as necessary
MK16 MOD 0 technical manual is found in the following publication:

A. SS521-AG-PRO-010

B. THE MAN TEN...

C. SS600-AH-MMA-010

D. SS600-AQ-MMO-010
C. SS600-AH-MMA-010
While on a dive, you experience some tingling of the lips and twitching of the facial muscles. Select the appropriate actions to follow immediately:

A. ignore until symptoms are serious enough to warrant consideration

B. ascend, secure diluent, add oxygen as necessary, terminate dive

C. notify your buddy and descend 10 fsw, then terminate dive if symptoms show no improvement within 15 minutes

D. ascend, add diluent, secure oxygen bottle in case of uncontrolled oxygen addition, terminate dive.
D. ascend, add diluent, secure oxygen bottle in case of uncontrolled oxygen addition, terminate dive.