Types of hyperbaric chamber

Standard navy double lock


Transportable rcf


Flyaway rcf


Double lock 100-202 cubic foot steel chamber


Double lock 200- 425 cubic foot steel chamber


Rcf 6500


Rcf 5000

Materials not allowed in chamber

Flammable items, cell phones, polyester except 65/35 poly/cotton

Primary air must have sufficient air to pressurize inner lock once and outer lock twice to ____?

165 fsw

Primary air must have enough air to press inner lock once and outer lock twice to?

165fsw

What are the different methods of communication

Comms, sound powered phone and, non chipping hammer

What is the chamber logged used for?

Everything when conducting a hyperbaric chamber treatment,LS, LB, stops, breaks, using med lock , swapping inside tenders, including what is being communicated.

Why are gag valves wired open? And when are they closed

So they don't isolate the relief valves. And when the relief valve fails

You are the chamber operator on a routine dive to 60 feet and you hear air moving and your gauge is rapidly losing death. What is your course of action?

Add to maintain, notify supervisor, do as supervisor directs you too, as the problem is being fixed, ensure exhaust valve is closed.

The diving supervisor asked you for chamber environmentals and to write them in the log, what are you writing down.

Air and stowage, oxygen level, CO2 level, temperature, depth.

Clothing worn by chamber occupants shall be at 100% cotton or flame retardant material such as?

65% polyester 35% cotton

What must a chamber have in order to be considered a modernized chamber?

Bibs overboard dump, air and out to babes, environmental heating/cooling unit, CO2 scrubber, 02, CO2 sensors.

What is the greatest hazard in a recompression chamber and why?

Fire because of compressed air, and being in a tight space, 02 may be present in chamber as well which is highly flammable.

Convert 20 PSI to ATA.

20+14.7÷14.7