The Ice detectors activate the green ICE advisory EICAS message when
Airframe icing is detected and both cowl anti icing systems and the wing anti icing system is turned on
The wings and cowls are heated to prevent is accretion by
14th stage bleed air. Cowls and wings are heated from the respective engine, wings may be heated from either engine
What airframe surfaces are heated to prevent ice accretion
Wing and cowl leading edges
When the WING switch is selected to NORM position, wing temp is maintained at what temp
88c
Adequate wing anti ice heating is indicated by
Illumination of the related green HEAT caption in the annunciator in the WING switch group

The green WING A/ICE ON advisory EICAS message
The wing anti ice shutoff valves are operated how
Are spring loaded closed, electrically controlled, pneumattically operated
The amber WING A/ICE SNSR caution EICAS message indicates
A normal or overheat temperature probe in either wing failed
The red WING OVHT warning EICAS message indicates
The temp of either wing is excessive at any time
An amber Wing A/ICE caution EICAS message indicates
Bleed-air pressure downstream of the related anti-icing valve is too low and the green HEAT caption has subsequently extinguished
While operating wing anti icing in the standby mode heating of each wing is independently controlled by
reference to the standby temp sensor
The red ANTI-ICE DUCT warning EICAS message indicates
A bleed air leak in either 14th stage bleed air line extending from the anti icing valves to the wing roots or a break in the piccolo tube in ether leading edge
Selecting COWL ant-icing ON
Heats the related engine inlet lip and duct, T2 probe and thrust reverser actuators with 14th stage bleed air
Proper operation of both cowl anti icing systems is indicated by
The green COWL A/ICE ON advisory EICAS message

illumination of the green ON caption in the related COWL switch light
The cowl anti icing pressure regulating shutoff valves are
Spring loaded open, electrically controlled, pneumatically operated
An amber COWL A/ICE caution message indicates
A mismatch in COWL switchlight selection and pressure in the related cowl anti icing system (switch ON with low pressure or switch off with pressure detected)
Air data probes on the left forward fuselage are supplied heating power from
AC essential bus
The TAT probe is heated
At all times power is available from AC bus 1
Selecting a PROBES switch off while airborne
Causes display of all onside probe heating messages
Air data probe heating is inhibited while on the ground if
Both IDG generators are not operating

The passenger door is open
When the WSHLD/WIND swithches are selected to HI
Only the windshield increases to approximately 58c
An amber WSHLD HEAT caution EICAS message indicates the related windshield
Has over heated, has an open or shorted temp sensor, heating power failed, or the controller failed.