Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
19 Cards in this Set
- Front
- Back
Noncombustible |
Protected: I-A II-A / Less Protected: I-B / Unprotected: II-B
|
|
Combustible: Mixed Systems
|
Protected: III-A / Less: III-B
|
|
Combustible: Heavy Timber
|
Less Protected: IV
|
|
Combustible: Any Materials
|
Protected: V-A / Not: V-B
|
|
Noncombustible: Examples
|
Masonry, Concrete and Steel
|
|
Combustible: Examples
|
Wood, Plastics
|
|
Fire Resistance
|
Limit spread of fire: building to building, area to area, floor to floor
|
|
Compartmentalization
|
Internal Fire Resistance
|
|
Passive Fire Resistance
|
Type of Construction
|
|
Active Fire Resistance
|
Sprinklers, etc.
|
|
Type I-A
|
Structural: 3 - Bearing E/I: 3/3 - Floor: 2 - Roof: 1.5
|
|
Type I-B
|
Structural: 2 - Bearing E/I: 2/2 - Floor: 2 - Roof: 1
|
|
Type II-A
|
Structural: 1 - Bearing E/I: 1/1 - Floor: 1 - Roof: 1
|
|
Type II-B
|
Structural: 0 - Bearing E/I: 0/0 - Floor: 0 - Roof: 0
|
|
Type III-A
|
Structural: 1 - Bearing E/I: 2/1 - Floor: 1 - Roof: 1 Exterior Prevents Fire Spreading - Office/Residential |
|
Type III-B
|
Structural: 0 - Bearing E/I: 2/0 - Floor: 0 - Roof: 0 Exterior Prevents Fire Spreading - Office/Residential
|
|
Type IV
|
Structural: 2 - Bearing E/I: 2/1 - Floor: HT - Roof: HT - Heavy Timber - Storage, Heavy metal doors/shutters - Burning and charring protects the interior of the wood from burning, no concealed spaces. |
|
Type V-A
|
Structural: 1 - Bearing E/I: 1/1 - Floor: 1 - Roof: 1 - Single family homes |
|
Type V-B
|
Structural: 0 - Bearing E/I: 0/0 - Floor: 0 - Roof: 0 - Single family homes Exceptio: table 602 requires exterior wall to be 1 for H occupancy |