  • Front
  • Back

Noncombustible

Protected: I-A II-A / Less Protected: I-B / Unprotected: II-B
Combustible: Mixed Systems
Protected: III-A / Less: III-B
Combustible: Heavy Timber
Less Protected: IV
Combustible: Any Materials
Protected: V-A / Not: V-B
Noncombustible: Examples
Masonry, Concrete and Steel
Combustible: Examples
Wood, Plastics
Fire Resistance
Limit spread of fire: building to building, area to area, floor to floor
Compartmentalization
Internal Fire Resistance
Passive Fire Resistance
Type of Construction
Active Fire Resistance
Sprinklers, etc.
Type I-A
Structural: 3 - Bearing E/I: 3/3 - Floor: 2 - Roof: 1.5
Type I-B
Structural: 2 - Bearing E/I: 2/2 - Floor: 2 - Roof: 1
Type II-A
Structural: 1 - Bearing E/I: 1/1 - Floor: 1 - Roof: 1
Type II-B
Structural: 0 - Bearing E/I: 0/0 - Floor: 0 - Roof: 0
Type III-A

Structural: 1 - Bearing E/I: 2/1 - Floor: 1 - Roof: 1 Exterior Prevents Fire Spreading - Office/Residential

Type III-B
Structural: 0 - Bearing E/I: 2/0 - Floor: 0 - Roof: 0 Exterior Prevents Fire Spreading - Office/Residential
Type IV

Structural: 2 - Bearing E/I: 2/1 - Floor: HT - Roof: HT - Heavy Timber - Storage, Heavy metal doors/shutters - Burning and charring protects the interior of the wood from burning, no concealed spaces.

Type V-A

Structural: 1 - Bearing E/I: 1/1 - Floor: 1 - Roof: 1 - Single family homes

Type V-B

Structural: 0 - Bearing E/I: 0/0 - Floor: 0 - Roof: 0 - Single family homes


Exceptio: table 602 requires exterior wall to be 1 for H occupancy