Establish initial vacuum in the Main Condenser
|
Condenser Air Removal System
|
|
Remove non-condensible, radioactive and potentially explosive gases from the Main Condenser
|
Condenser Air Removal System
|
|
The Mechanical Vacuum Pumps are _____ type compressors
|
water-sealed, rotary air
|
|
Mechanical Vacuum Pumps take a suction on the _____ and discharge through a discharge separator and discharge silencer to the ____
|
Main Condenser / Turbine Plant Ventilation Filter Train.
|
|
The ___ SJAE removes noncondensible gases from the SJAE Intercondenser and discharges them along with its driving steam to the ___ for processing
|
second stage / Offgas System
|
|
The first stage SJAE takes a suction directly from the _____ through a baffled region, to ensure most of the gas flow is dry, and discharges into the SJAE Condenser (Intercondenser) where the steam is condensed by Condensate System flow going through the SJAE Intercondenser tubes.
|
low pressure Main Condenser shells
|
|
Each SJAE uses a high velocity jet of ____to act as a jet pump for the removal of noncondensible gases from the ____.
|
steam / Main Condenser shells
|
|
- Minimize and control the release of radioactive gas into the atmosphere
- Minimize the potential of a hydrogen explosion by reducing the hydrogen concentration to less than ___ |
Offgas
4% |
|
Heats the gas mixture coming from the Second Stage Air Ejector, using Main Steam, to remove moisture and raise Recombiner efficiency
|
Preheaters
|
|
Preheaters - Heats the gas mixture coming from the ____, using Main Steam, to remove moisture and raise Recombiner efficiency
|
Second Stage Air Ejector
|
|
Recombines the hydrogen and oxygen to reduce the Offgas volume and hydrogen concentration
|
Catalytic Recombiner
|
|
Reduces mixture volume by condensing the water vapor in the process flow using Condensate as the cooling medium
|
Offgas Condenser
|
|
Removes entrained water droplets from the process flow
|
Water Separator
|
|
Delays process flow by providing a tortuous path to allow decay of short-lived isotopes
|
Holdup Line
|
|
Cools gas mixture using Glycol as a cooling medium
|
Cooler Condenser
|
|
Removes water droplets prior to the process entering the Prefilters
|
Moisture Separator
|
|
Removes particulate daughter products which come from decay of short-lived noble gases
|
Prefilter
|
|
Removes moisture and lowers the dew point of the process flow prior to entry into the Charcoal Beds. System has regenerators which regenerate the desiccant dryer when required.
|
Gas Dryer System
|
|
Adsorbers adsorb (holdup) fission products to allow gas release to be within acceptable limits. Refrigerated vault maintains temperature very low to ensure process flow is slow to enhance adsorption process
|
Refrigerated Charcoal Adsorbers and Vault
|
|
Filter out any remaining particles including charcoal particles prior to the process entering the Main Plant Exhaust Ventilation
|
After Filters
|
|
State what happens to the Offgas System upon a High-High-High Radiation Signal on the final discharge line including the effects on plant operation.
|
The Offgas System isolates upon a High-High-High Radiation alarm on its discharge. If the problem was not corrected immediately, Main Condenser vacuum would be lost and the plant would have to be shut down.
|
|
The Standby Diesel Generators (Div I and Div II) will automatically start when the following conditions are present:
|
RPV Water Level Low – Level 1
High Drywell Pressure – 1.68 psid Associated Emergency Bus undervoltage |
|
The Standby Diesel Generators are normally in a ____– ready for automatic start condition. (Normally not running.)
|
standby
|
|
The Standby Diesel Generators supply power to ____ when needed.
|
safety-related loads
|
|
The Standby Diesel Generators are rated for _____.
|
3130 Kw
|
|
The HPCS DIESEL GENERATOR will automatically start when the following conditions are present:
|
RPV Water Level Low – Level 2
High Drywell to Containment Pressure – 1.68 psid |
|
The HPCS DIESEL GENERATOR is rated for ____.
|
2600 Kw
|
|
What is the HPCS Diesel Generator's respective emegency bus?
|
DIC III, E22-S004
|
|
State the five (5) types of parameters monitored by the Leak Detection System.
|
Temperature
Pressure/Differential Pressure Flow rate/Differential Flow Rate Sump Liquid Levels Radiological Conditions |
|
The function of the ____ is to detect leakage from the various systems connected to the reactor vessel, to provide indications, alarms, and some automatic actions.
|
Leak Detection System
|
|
C. Describe how leakage in the Drywell is detected. (3)
Leakage in the Drywell is detected by the following means: |
High Drywell to Containment Differential pressure
High Drywell temperature High Drywell air cooler condensate flow High Drywell airborne activity Changes in floor and equipment drain sump levels |