BUMEDINST 6260.30A
Mercury Control Program for Dental Treatment Spaces
Purpose for BUMEDINST 6260.30A
Est. minimum handling procedures for elemental mercury in dental treatment spaces to minimize pers exposure and environmental contaminiation. Does not apply to organic mercury compounds.
At what temp does mercury vaporize?
Room temp
What is a misture of several metalk including mercury that has reduced the potential for mercury exposure during routine dental procedures?
Dental amalgam
Although mercury in the form of dental amalgam is very stable, it should be disposed of how?
recycled
What must be removed prior to Dental personnel work with mercury-bearing materials (amalgam or scrap amalgam)?
All Jewelry which could potentially become contaminated and permanently damaged
All work surfaces must be made of?
Impervious material, preferably stainless steel or plastic laminate
What technique must personnel use when handling amalgam?
"no-touch"
After trituation of the pre-encapsulated amalgam, what must personnel use while loading the amalgam carrier?
An amalgam well
How often are amalgamator enclosures inspected for mercury globules?
weekly, they must be cleaned following enclosure
Referring to the Amalgamators, capsules, and any other items which may be contaminated with mercury must be stored in impervious catch trays and checked for mercury droplets how often?
weekly
Who may disassemble an amalgamator?
Only a qualified dental repair specialist
T/F Amalgam scraps can be stored dry without eceeding any personnel exposure level for mercury vapors in the breathing zone of dentists and techs.
True
T/F Based on 40 CFR, Part 261, dental amalgam does not qualify as a recyclable material.
True
Are dental amalgam scraps considered a Resource Conservation and Recovery Act (RCRA) hazardous waste?
YES
All dental scraps must be transferred to the local DRMO in what type of container and labeled how?
Tightly closed unbreakable container.
Label container and all documentation as "RCRA Hazardous Waste-Dental Scrap Metal"
What type of preferred floor covering material is used for DTRS? What is NOT permitted?
Vinyl sheet
Carpet
Mercury decontaminant must be readily available for immediate mising and application to a contaminated surface, what is it called?
HgX
Who must be contacted to test the docontaminated area and equipment for residual mercury after a spill and cleanup procedures are complete?
Congnizant Industrial Hygiene Office
For shipboard only, all mercury-contaminated waste, including scrap amalgam must be disposed of how?
Collected, packaged with a double boundary of confinement using plastic bags, sealable drums, or polyethylene bottles , and labeled.