- Front
- Back
BUMEDINST 6260.30A
|
Mercury Control Program for Dental Treatment Spaces
|
|
Purpose for BUMEDINST 6260.30A
|
Est. minimum handling procedures for elemental mercury in dental treatment spaces to minimize pers exposure and environmental contaminiation. Does not apply to organic mercury compounds.
|
|
At what temp does mercury vaporize?
|
Room temp
|
|
What is a misture of several metalk including mercury that has reduced the potential for mercury exposure during routine dental procedures?
|
Dental amalgam
|
|
Although mercury in the form of dental amalgam is very stable, it should be disposed of how?
|
recycled
|
|
What must be removed prior to Dental personnel work with mercury-bearing materials (amalgam or scrap amalgam)?
|
All Jewelry which could potentially become contaminated and permanently damaged
|
|
All work surfaces must be made of?
|
Impervious material, preferably stainless steel or plastic laminate
|
|
What technique must personnel use when handling amalgam?
|
"no-touch"
|
|
After trituation of the pre-encapsulated amalgam, what must personnel use while loading the amalgam carrier?
|
An amalgam well
|
|
How often are amalgamator enclosures inspected for mercury globules?
|
weekly, they must be cleaned following enclosure
|
|
Referring to the Amalgamators, capsules, and any other items which may be contaminated with mercury must be stored in impervious catch trays and checked for mercury droplets how often?
|
weekly
|
|
Who may disassemble an amalgamator?
|
Only a qualified dental repair specialist
|
|
T/F Amalgam scraps can be stored dry without eceeding any personnel exposure level for mercury vapors in the breathing zone of dentists and techs.
|
True
|
|
T/F Based on 40 CFR, Part 261, dental amalgam does not qualify as a recyclable material.
|
True
|
|
Are dental amalgam scraps considered a Resource Conservation and Recovery Act (RCRA) hazardous waste?
|
YES
|
|
All dental scraps must be transferred to the local DRMO in what type of container and labeled how?
|
Tightly closed unbreakable container.
Label container and all documentation as "RCRA Hazardous Waste-Dental Scrap Metal" |
|
What type of preferred floor covering material is used for DTRS? What is NOT permitted?
|
Vinyl sheet
Carpet |
|
Mercury decontaminant must be readily available for immediate mising and application to a contaminated surface, what is it called?
|
HgX
|
|
Who must be contacted to test the docontaminated area and equipment for residual mercury after a spill and cleanup procedures are complete?
|
Congnizant Industrial Hygiene Office
|
|
For shipboard only, all mercury-contaminated waste, including scrap amalgam must be disposed of how?
|
Collected, packaged with a double boundary of confinement using plastic bags, sealable drums, or polyethylene bottles , and labeled.
|