  • Back
power
energy / time
B.T.U.
British Thermal Units
sustainable design
design that will have overall beneficial effects on productivity, heat, resources, econonmics (water and heat conservation)
what is the function of plumbing facilities in buildings?
-convenince
-accommodate the fluctuation in a building
-occupants avoid congestion
fire sprinkler systems
A- Ordinary combustibles
B- liquids
C- electrical
D- Metals
K- kitchen grease
devices for fire detection
Manual alarm station
Thermal detector
power(watts)
Volts x amps
Energy
power x time
Voltage Transformation
Voltage can be changed using simple peices of electrical equipment known as a transformer
what is stack effect in a high rise building?
depends heavily on the HVAC system to counteract the natural air movement in the building
when are fire Pumps used
they are used when the residual water pressure at the most remote sprinkler heads of an autmomatics sprinkler is inadequate
stand by power
involves the use of an engine driven generator so power is interrupted during startup and switching
digital signals
Are separate on/off pulses
if a motorized equipment rated for 50hz is connexted to 60hz system what will happen?
the motor runs 20 % faster as long as voltage is not changed
can Rigid non metallic conduit be placed in concrete?
is allowed to be cast in concrete and in wet soils
transformers change
AC not DC
Janis Tao text defines these levels of voltage
5 to 10%
voltage fluctuation
max even in unusual situations 5%
how is a power plant different from coal power
Nuclear is an closed system, coal is an open system
two reasons raceway fill is limited
1. prevent excesive overheating
2. to allow practical pulling of conductors
what are two reasons raceway fill is limited?
1, reduce heat
2. make pulling wires easier
list two differences to consider when installing rigid non metallic conduit.
it has to have a ground wire in it
you can thread the ends
what are the precautions when threading rigid non metallic tubing
none because you cannot thread it
12 guage mc cable vs. 90Degree #12 conduit carry the same amps?
no, just because the conductors are the same dosent mean you carry the same amps
list two advantages of AC over DC
AC system has lower generation cost
Ac system is easier to convert
what is allowable amapcity of single 90 rated 10 copper conductor vs. one with three in the same conduit
carry 30 amps b/c the heat is able to escape b/c there only one conductor opossed the three