Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
32 Cards in this Set
- Front
- Back
Swimming pool barriers applies to all poos or spas >__in deep
|
24
|
|
Barrier fence req'd min __ in high
|
48
|
|
Bottom of fence max __in above grade
|
2in
|
|
Max opening <__in, fence not climbable
|
4in
|
|
Gate lockable, self-closing, open __ pool
|
away from
|
|
If latch <__in high, must be poolside & min __in from top.
|
54in / 3in
|
|
No openings >__in within 18in of gate latch
|
1/2in
|
|
Doors & screen doors w/ direct pool access req alarm audible throughout house within __seconds of opening for __seconds duration
|
7sec / 30sec
|
|
Alarm control min __in high, automatically resetting
|
54in
|
|
Illumination req'd for all stairways
|
True
|
|
Switch req'd top & bottom of interior stairs >= __ risers
|
6 risers
|
|
Floor or landing req'd at top & bottom of interior stairways (including garage) exc where door does not swing over stairs
|
True
|
|
Headroom min __
|
6ft 8in
|
|
Min stairway width above handrail __in
|
36in
|
|
Handrail may project into req'd width __in
|
4.5in
|
|
Max riser height __in
|
7 and 3/4 in
|
|
Min tread depth __
|
10 in
|
|
Max difference between tallest and shortest riser or largest & shortest tread run __in
|
3/8in
|
|
Winder tread min __in & develop req'd length at __in from inside of winder.
|
6in / <=12in
|
|
Nosing min __in max __in req'd on stairs w/ solid risers EXC nosing not req'd if tread depth >= __in
|
3/4in / 1and1/4in / >=11in
|
|
Grippable handrail req'd if __ or more risers
|
4
|
|
Handrail height min __in max __in
|
34in / 38in
|
|
Grips min __in max __in circular cross section
|
1and1/4in / 2in
|
|
Min __in between wall & handrail
|
1and1/2in
|
|
Ends must return to __ or __
|
wall or newel post
|
|
Handrail on open side of stairs must not allow __ sphere to pass through
|
4in
|
|
Openings between treads of open risers <__in
|
<4in
|
|
Triangular space between riser, tread & rail must not allow __in sphere to pass through
|
6in
|
|
Guardrail req'd for any walkoff >__in above floor or grade
|
>30in
|
|
Min height for guardrails __in
|
36in
|
|
Opening must not allow __in sphere to pass through
|
4in
|
|
Guards w/ openings, __in req'd on open sides of stairs if total rise above floor or grade >30in
|
4and3/8in
|