25 Cards in this Set

  • Front
  • Back
Fireblocking req'd at concealed space under stairs at top & bottom of stringers
T
Enclosed accessible space below stairs req's __in gypsum board
1/2in
Fireblocking req'd in concealed spaces of stud walls max __ft horiz
10ft
Floor/ceiling draftstopped if >__sqft or ceiling suspended from floor framing
1000 sqft
Draftstop material __in gypsum or __in panels
1/2in / 3/8in
Min __in gypboard on garage side of walls common to house
1/2in
Min __in gypboard on garage ceiling common to house
5/8in
Ducts from house to garage min __gauge steel
26 gauge
No duct openings into garage
t
No openings between garage & sleeping rooms
t
Door between house & garage rated __ or __ solid core
20-minute / 1and3/8 in solid core
NFPA 72 fire alarms OK if equivalent to __
smoke alarms
Req'd in each sleeping room & __
adjoining area
Min __ detector each story including basements
1
Interconnect so activation of one alarm sets off __
all alarms
Battery power alone OK for remodel where __
no finishes removed
Heat req'd in habitable rooms __degrees __ ft above floor
68 degrees 3 ft above floor
min one room >=__sqft
>=120sqft
Habitable rooms exc kitchens min __sqft & min dimension __ft
70sqft / 7ft
sloped ceiling rooms min __ must be >= __ft ceiling & areas <__ft do not count toward required floor area.
50% / >=7ft / <5ft
Ceiling height habitable space min __ft
7ft
Kitchens, baths, & hallways min ceiling height __ft EXC __OK in baths over fixture & front clearance area.
7ft / 6ft 8in
Ceiling height unfinished basements min __
6ft 8 in
Water service min __in deep & __in below frost line
12 in / 6 in
Water & sewer OK in same trench if sewer material approved in house OR __ft separation OR water __in above sewer.
5ft / 12in