Dose rate for HDR
up to 400 cGy/min
Doser rate for LDR
40 - 200 cGy/hr
Cs 137 uses
tandem and oviods, LDR
Definition: point A for gyno implants
2 cm cephalad external cervical os, 2 cm lat uterine tandem
Defintion: point B
Used in Manchester system for intracavitary implants, 3 cm pt A and represents level obdurator nodes
Definition: basal dose
85% of the minimal doses between all sources, used in Paris system
Why does does dist for brachy follow ISF?
Attenuation and scanner dose build up cancel out
When is ISF not accurate for iso?
low energy sources
energy Gold 198
410 keV
energy Pd 103, half life
21 keV, 17 days
Iodine 125: use
perm seeds
Ir 192: use
LDR HDR
What source used for tandem and ovoids?
Cs 137
Define total source strength
Kerma in air at 1-meter
Isotope for nasopharyngeal implants
Cs 137
Source used for HDR
Ir 192
Three sources used for permanent implants
I-125, Pd-103, Gold-198
LDR sources
Cs 137, Ir 192
Radioactive sources in tandems and ovoids are in this form
tubes
Isotope energy 29 keV
I-125
Isotope energy 370 keV
Ir 192
Isotope energy 410 keV
Gold 198
Ref pts for intracavity brachy by ICRU
bladder and rectal wall, lymph trapezoid, pelvic wall pts
System of implants defines stated dose as max dose?
Quimby
System of implants defined states dose as min?
Manchester or PP
Which system of implants does NOT use crossing needles?
Paris, source length 40% greater target volume
Spacing of implants varies with target
PP
Even spacing implants 1 cm apart
Quimby
Variable but equal spacing implants
Paris
Constant linear activity, implant system?
Paris or Quimby
No restrictions to pt at this dose rate
0.1 mRm/hr
limit contact w children at this dose rate
> than 0.2 mRm/hr
Single channel Bougie applicator
esophagus
Single channel candle applicator
vaginal
vaginal applicators
single channel candle, tandem and ovoids
multichannel needle template
prostate, rectum
multiplane needle template
breast
applicator skin
single-plane multi channel applicator
relationship between half life and tx time
shorter half life, shorter tx time
relationship initial dose rate and half life
shorter half life, larger initial rate
relationship tx time and initial activity
higher activity means shorter tx time
# dps in 1 Ci
3.7 10^10
SI unit activity
Bq
Which rad transport label does NOT require T1?
White 1
Yellow 1 indicates?
50 mrem or LESS at surface
If T1 exceeds 1 mrem at 1 m
Yellow 2
Occupational dose limit to hands
500 mSv or 50 rem
max annual exposure whole body for training
1 mSv