Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
130 Cards in this Set
- Front
- Back
How long is 21-511?
|
47 feet
|
|
What is the pump make and rating on our 2007 BME?
|
Single stage Hale QMax rated at 1500 GPM
|
|
GVW for 21-511?
|
73,500 lbs
|
|
What is the flow GPM on Ladder ones's shower nozzle?
|
100 GPM
|
|
How long is the bumper pre-connect on our apparatus?
|
150'
|
|
Engine 27 uses what type of primer pump?
|
Electric rotary vane
|
|
What is the hydraulic oil capacity on Ladder 1?
|
70 gals.
|
|
How many feet of 4" LDH hose is on our apparatus?
|
1000'
|
|
How many gallons of A foam is on Engine 3?
|
40 gals.
|
|
At what pressure do we pump B foam on the 1994 E-One?
|
200 PSI
|
|
What is the pump make and rating of Ladder 1?
|
Waterous 1500 GPM
|
|
Engine 1 generator is powered by what source?
A Propane B Diesel C PTO |
PTO
|
|
What is the water tank capacity on ARFF 4?
|
1500 Gal.
|
|
Most hydraulic pumps are not capable of operating the tool at full power when the length between the pump and the tool exceeds how many feet?
A 75 B 125 C 100 D 50 |
100 feet
|
|
Automatic pressure control devices must not allow the pressure to exceed________PSI above the set level
|
30 PSI
|
|
How many 110 volt outlets are there in Ladder 1's bucket?
|
4
|
|
What is the maximum GPM flow of the monsoon nozzle on 21-511?
|
1500 GPM
|
|
What is reaction distance in relation to stopping an apparatus?
|
The distance a vehicle travels while a driver is transferring the foot from the accelerator to the brake pedal after perceiving the need for stopping.
|
|
How many pounds of dry chemical are on ARFF 4?
|
450 lbs
|
|
When operating ARFF 21-243 do not engage the pump over how many RPM's?
|
1000 RPM's
|
|
What is the booster tank capacity on our Engines?
|
1000 gal.
|
|
How many feet of 1" booster hose is on Engine 1?
|
200 feet
|
|
What is the maximum vertical reach of Ladder 1's aerial ladder?
|
102 feet
|
|
What is the size of the tank to pump piping on Ladder 1?
|
2 1/2"
|
|
What is the nitrogen bottles max pressure on ARFF 4 (21-243)?
What is the minimum pressure before refill? |
2640 PSI
1900 PSI |
|
Blue lights at airports are used for______ and are spaced how many feet apart?
|
Taxiway edges and 100 feet apart
|
|
If you receive a flashing white light from the airport tower. What should you do?
|
Return to fire station or starting point
|
|
What are the five main parts of Ladder 1?
|
Cab, Pump Panel, Platform, Outriggers and Inventory
|
|
According to SOP when an evacuation is ordered by the IC what is the responsibility and procedure of the Driver/Operator?
|
Sound the air horn three times, one second long with a one second delay in between
|
|
What is the maximum payload in the Tower bucket when performing water operations?
|
400 lbs.
|
|
The breathing system on Ladder 1 is how many cubic feet?
|
544 total, 277 in each bottle
|
|
How many different locations can you start the emergency hydraulic pump on Ladder 1, and where are they located?
|
3: On the pump itself by the left front outrigger, rear control panel, and turntable
|
|
How much 4" LDH is loaded on Ladder 1's hosebed?
|
1000'
|
|
What weight of oil is used for Engine 28's primer pump?
|
30 wt
|
|
Engine 2's pump seals are______?
|
Mechanical
|
|
What is ARFF 4 (21-243's) pump rated?
|
1520 GPM @ 230 PSI
|
|
What is the flow for the roof turret on ARFF 4? High and Low
|
750 high flow 375 low flow
|
|
The ARFF truck's gradability is?
|
60%
|
|
How many total ground ladders are on Lladder 1?
|
7
|
|
How many water outlets are there in Ladder 1's bucket?
What are their sizes? |
5
(2) 2 1/2", (1) 1 3/4", (1) 1", (1) 4" |
|
What are the names of the taxiways at the Twin Falls airport?
|
Alpha 1-5, Golf, Hotel, Juliet, Kilo, Lima
Runways 26(E)-8(W) and 30(S)/12(N) |
|
A steady read light from the ATCT means?
|
Stop! Do not proceed
|
|
The front bumper line on ARFF 4 (21-243) discharges_____GPM?
|
300 GPM
|
|
The 1 3/4" hand lines on ARFF 4 (21-243) discharge________GPM?
|
95 GPM @ 230 PSI
|
|
What is the 10 second rule as it pertains to the ARFF truck?
|
If you are not flowing water for 10 seconds, shut the pump down
|
|
What year and make is Engine 28?
|
1994 E-One
|
|
What are the 3 red lines you must observe on Tower 1?
|
1500 RPM max. with PTO engaged
200 PSI max. to Tower Line 20 PSI min. intake pressure |
|
What is the maximum GPM flow when operating from a draft using 4.5" hard suction?
|
750 GPM
|
|
When operating from a public or private water system, do not allow the incoming pressure from a hydrant to drop below_____PSI?
|
20 PSI
|
|
What is the recommended discharge pressure while hooked to an FDC?
|
150 PSI
|
|
What is the GVW of ARFF 4 (21-243)?
|
50,000 GVW
43,740 Actual with full load |
|
ARFF 4 (21-243's) pump operating pressure is_____PSI at______RPM's?
|
230 PSI @ 2250-2300 RPM
|
|
Ladder 1 is how many feet from outrigger to outrigger?
|
18 feet
|
|
Ladder operations can be done in winds up to_____ MPH winds?
|
50 MPH, with tie down ropes
|
|
The intake screens on Ladder 1 are called__________and are made of______?
|
Cathodic protection device
die cast zinc |
|
Fire pump seals on Ladder 1 are_______?
|
Mechanical
|
|
How many minutes of water can you get from the bumper turret on ARFF 4 (21-243)?
|
5 minutes @ 300 GPM
|
|
Green lights at airports identify______?
|
Approach ends of the runway
|
|
How many places can you start the auxiliary generator on Ladder 1?
Where are they located? |
3
Cab, Pump panel, and the Generator itself |
|
When operating an apparatus on a code response, is it okay to just use lights without sirens?
|
No, Code is all or nothing
|
|
How many intercoms are on Ladder 1?
|
3
Pump panel, Turntable, and Bucket |
|
What is the foam tank capacity on ARFF 243?
|
210 gals.
|
|
How many tanks of water can you go through with one full tank of foam on the ARFF truck?
|
4.67 tanks
|
|
How many pound per second of dry chemical can you discharge from the roof turret?
|
16 PPS
|
|
What is the diameter of the water way swivel on Ladder 1?
|
5"
|
|
Alternating green and red lights at the airport suggests?
|
Proceed with caution
|
|
Most manufactures specify that the pump remain in pressure mode, until it is necessary to flow more than_____of the rated capacity?
|
2/3 rds
|
|
Where are the ladder drains on 21-511, and how many are there?
|
2
Rear of apparatus, and Captains side pump panel |
|
How much 2 1/2" hose total is on Tower 1?
|
700 feet
|
|
On stand pipe systems allow_____PSI for friction loss. This covers FDC, clapper valves, valve obstructions, pipe bends, and hose connections
|
25 PSI
|
|
When pumping sprinkler or standpipe connections your transfer valve should be in which position?
|
Volume or RPM
|
|
When priming a fire apparatus you should achieve a prime in____seconds. If not primed continue to pull primer but do not prime for more than_____seconds?
|
10-15 seconds, no more than 30 seconds
|
|
The Akron piercing nozzle is rated at_____GPM at ______PSI?
|
100 GPM @ 125 PSI
|
|
How long will it take to fill 21-243 from a hydrant flowing 80 PSI?
|
2 minutes
|
|
What size is the water tank fill line on Ladder 1?
|
1 inch
|
|
What is the maximum payload in the bucket, when not doing water operations?
|
800 pounds
|
|
_______Powers the emergency hydraulic pump on Ladder 1 (21-511)?
|
12 Volt DC
|
|
What is the make of the water pump on the 2000 E-One?
|
Hale QMax
|
|
The lights that outline the runways are________and are spaced_______feet apart?
|
White, 200 feet apart
Last 2000' are amber |
|
While pumping a standpipe system you should add______PSI for each floor above?
|
5 PSI
|
|
How many gallons of water are in the booster tank on Ladder 1?
|
200 gallons
|
|
Who is the maker of the 1994 reserve apparatus?
|
E-One
|
|
How many feet of 1" hose is on the Ladder?
|
200 feet
|
|
Where is the hose burst jacket located on Engine 1 (21-118)?
|
Driver's side front compartment
|
|
At an airport a flashing red light from the ATCT or flashing runway lights mean _________?
|
Clear the runway immediately
|
|
What are the recommended discharge pressures from the 2 1/2" lines on 21-243?
|
80-90 PSI
|
|
How many pounds per second can you flow dry chemical from the bumper line on 21-243?
|
6 PPS
|
|
While flowing water on high flow through the roof turret on the ARFF truck, how many minutes can you flow?
|
2 minutes
|
|
While flowing water from the tower line on 21-511 you should not increase the pressure above____PSI?
|
200 PSI
(recommended flow of 175PSI) |
|
Where are the bolt cutters located on Engine 2 (21-122)?
|
Captain's side engineer's compartment
|
|
What is the max speed for the ARFF truck?
|
65 MPH
|
|
For tire and wheel fires on aircraft you should approach from the _______?
|
Tread or you are dead
|
|
Over heated landing gear should be allowed to ________ naturally?
|
Cool
|
|
With the PTO engaged on 21-511 do not exceed ________ RPM's?
|
1500 RPM's
|
|
Packing rings are used to make a seal at the point where the shaft passes through _________ on the pump?
|
Casing
|
|
At airports amber lights identify.....
|
Hold bars and the last 2000' of the runway ends
|
|
How many pike poles are on 21-511?
|
Seven
|
|
At high idle RPM's should be......
|
900-1100 RPMs
|
|
Where is the hydraulic pump located on ARFF 4 21-243?
|
Drivers side rear compartment
|
|
How many intake only ports are on Ladder 1 21-511?
|
Four
|
|
The minimum safe distance from a wheel fire on an aircraft is ________?
|
300 feet
|
|
What is the recommended tire pressure on ARFF 4 (21-243)?
|
65 PSI
|
|
What is the foam proportioned at on ARFF 4 (21-243)?
|
3%
|
|
What is the minimum nitrogen pressure on the ARFF truck?
|
1900 PSI
But the test last year had 1500 PSI |
|
What type of dry chemical is used on 21-243?
|
Purple K
|
|
With an 1 3/4" line at 150 PSI how much time will a 1000 gallons of water last?
|
6.7 minutes
|
|
What is the GPM flow for the deck guns?
|
1250 GPM
|
|
While flowing water from an engine using the booster tank, what is the maximum flow?
|
500 GPM
|
|
Which lines can you flow foam from on 21-122?
|
Both Crosslays, Booster reel and Bumper line
|
|
Does the foam pro on 21-122 control the proportioning of B foam?
|
Yes
|
|
What equipment is on the fly section of Tower 1?
|
Attic Ladder, Pike Pole, and Trash Hook
|
|
Where are the air gauges for the breathing system on Ladder 1, and what do they do?
|
Pedestal control box gives full bottle pressure (2216), and in the Bucket gives intermediate pressure.
|
|
What size hard suction hoses do we carry on the engines?
|
4 1/2" hard suction
|
|
When do we do hose changes on the apparatus for each size of hose?
|
4" yearly
2 1/2" semi-annually |
|
Water comes in through the intake and enters which part of the pump?
|
Eye of the impellar
|
|
What are the types of positive displacement pumps?
|
Piston, Rotary gear, Rotary Vane
These pumps can pump air |
|
What is the most common cause of cavitation?
|
Inadequate water supply
Attempting to flow more water than is being supplied |
|
What is the first symptom of a pump wearing out?
|
Increased RPMs to flow a given pressure
|
|
While pumping water and using a hydrant. What is the first step in shutting down the operation?
|
Decrease engine RPMs
IDLE DOWN |
|
Which type of pump do we use to evacuate air from a centrifugal fire pump?
|
Rotary Vane positive displacement pump
|
|
Are the 2 1/2" discharges on ARFF 243 preset at 80 PSI?
|
No they are manually adjusted, with the valve and gauge next to the discharge
|
|
Where can you run the hydraulic ladder controls on Ladder 1?
|
Pedestal and the Bucket
Bucket is electrical over hydraulic |
|
When checking the hydraulic fluid on Ladder 1. What position should your hydraulic cylinders be in?
|
Retracted
|
|
On Engine #3, when does the door open light activate?
|
??? When park brake is released.
|
|
On the Class 1 Pressure Governor. What does the display read if pressure drops below 30 PSI? |
Intake |
|
On the Class 1 Pressure Governor. What does the display read if pressure increases 30 PSI? |
OPERATOR Will not increase pressure until D/O presses INC or Pre-Set. |
|
With a Class 1 Governor. How many seconds do you have to regain pressure, from a loss situation? What will the apparatus do and what will the display read? |
5 Seconds, Engine will then go to idle and LoSupply will be displayed. Ensure adequate supply then reinstate governor using the MODE, INC or PRESET buttons. |
|
What is the main function of the pressure governor in either Pressure or RPM modes? |
To maintain the last set pressure or RPM input, by the driver. As lines are opened and closed during operations. |
|
On the Class 1 or FRC governors can you switch between modes? |
Yes, you can switch with little or no noticeable effects to engine RPM's. |
|
What is displayed if an electrical fault or failure occurs, in the Class 1 Governor? What effects will it have on operations? |
SENSOR will be displayed for a fault, SENSOR will flash for a failure. Will no longer be able to maintain a pressure setting, but will hold the current RPM. |