Condensate and Boiler feed system

The purpose of these two is to deliver the condensate from the hotwell of the condenser to the boiler economizer.

Condensate Pumps

The _____ handle water at low pressure and must have a positive head on the suction pipe.

Shaft Glands

It prevents air leakage into the condensate from the pumps.

Cavitation

It can cause rapid wear of a pump impeller and shorten the life of the pump and also causes noise through the pump.

Hotwell

The ____ stores the condensate and also assures a head on the condensate pumps.



Evactor

It uses steam to remove the ncgs from the condenser.

Gland steam condenser

It is next to the evactor where it will pick up heat from the turbine steam seals.

U seal

The ____ seal prevents air from leaking into the condenser.

Recirculation

One way to increase main condensate flow is called ______ which diverts part of the main condensate back to the hotwell to be cooled.

Extraction

Another term for bleed steam.

Regenerative cycle

When steam is bled from the turbine at one or more stages to heat feedwater the steam - water cycle called ____.

Heat exchanger

Another term for HEATER.

Closed or non contact type / Open or direct contact type

Two basic groups of heat exchanger or heaters.

Closed or non contact type

In these heaters the water is separated from the steam by a metal wall.

Open or direct contact type

In these heaters the steam and heater are mixed together to obtain heating.

High or Low

_____ levels in a heater decrease its performance making it less efficient.

Heater drainage

The ____ can be pumped back into a condensate line or allowed to flow to the next lower steam pressure heater.

Deaerating heater

____ is an open type heater where the heated condensate is mixed with extraction steam.

Open heater

____ is simply a shell where all water and steam lines lead into the heater except one large line which drains to and vents the storage tank.

Deaerating heater

Its purpose is to remove dissolved oxygen from the condensate.

Boiler feed pump

It's purpose is to provide the boiler with enough water at a high enough pressure to replace the steam leaving the boiler.

Feedwater regulating valve

A valve that controls the amount of water supplied by the boiler feed pump.

Venting

It is accomplished by bleeding a small quantity of steam and gases from the confined spaces.

Internal leakage

______ through the tube walls cuts down the amount of heat picked up by the water and overloads the draining system.