  • Front
  • Back
1. Paraphrase the function of the Boron Recycle System.
Answer: The Boron Recycle System collects borated effluents for processing to be used elsewhere or eventual disposal to the environment.
2. List the influents into the Boron Recycle System.
RCDT pump discharge; pressure relief valves for the VCT, CCP's suction, RHR pump discharge, SIP's suction and discharge; CVCS boric acid blending tee; High pressure coolant injection system; Waste Evaporator Condensate Tank; Fuel Transfer Canal; SI Accumulators; Liquid Radwaste (HB) processing; Boron Thermal Regeneration System (BTRS); Gaseous Waste
3. Describe the function of the RHUT diaphragm.
Answer: The function of the diaphragm is to prevent air from dissolving into the water and to prevent the hydrogen and fission gases from escaping into the atmosphere.
4. Paraphrase the functions of the RHUTs.
Answer: Collection of effluents, suction head for the HE evaporator feed pumps, holdup for an RCS drain to centerline of the RV nozzles (including the PZR and SGs), storage for Fuel Transfer Canal water during refueling equipment maintenance, collects the discharge from various over pressure relief valves.
5. Explain how the BRS interfaces with the RHR system.