  • Front
  • Back
What prevents fuel from being dsciharged with water when the WDV opens.
vortex breaker
Which component controls operation of the WDV and FDV ?
Flange float control
Which valve automatically opens when the flange float control reaches the top position ?
WDV
Which component on the 40AF-2C controls the rate of flow through the filter separator ?
CDHS-2
Which component in the filter separator is designed to test the integrity of the ball float ?
FFC , CCF-21 Weighted Ballast
Which component in the vertical filter separator covers the coalescing elements ?
Separator Canisters
Which filtration component relieves excess thermal pressure ?
Pressure Relief
What two modifications are performed on the Mil Spec filter separator /?
Bowser Gammon
Which component on the 40AF-2C controls the rate of flow through the filter separator
CDSH-2
Which component in the filter separator is designed to test the integrity of the ball float ?
FFC weighted
What would cause a reading of zero on a differential pressure guage on a filter separator ?
blown separator elements
When must coalescing/separator elements be changed ?
defective elements
What could cause the filter separator elements to rupture ?
pump control valve out of adjustment
What size strainer screen will be used when repairing a strainer located before a Single point nozzle ?>
100 mesh
Screens that are split or separated on the seam can be repaired by _____ ?
50/50 Solder
Most coalescing elements are changed when the ____ limit is reached ?
15 psi
With the Vertical F/S how do you clean the separator canisters ?
vertically hold , with hot water, shake, screen
How do you drain the manifold on the Horizontal F/S
? ask
When filling separators how long should you wait to allow the elements to absorb the fuel ?
10 min
What should be stenciled on the F/S after replacing the coalescing elements ?
Next change date allowable differential pressure
What is the driving force of the meter ?
Fuel
Which component on a meter connects the metering mechanism to the counter head ?
drive gear train
Which meter contains a spiral meshed rotor?
brodie
Meters are calibrated _____?
Once a year, after repairs
The master meter must be calibrated every _____ gallons or every _____ months ?
1.2 million ,6months
Wetting down the master meter ensures what ?
Air removal
What is the calibration mechanism used in the Liquid control MEter
barrel and thimble
What should you NOT use when calibrating a meter ?
use aircraft as delivery point
Tank truck off loading headers will have at least one header adapted to off load ?
refueler
Off loading equipment is used for taking fuel out of
bulk storage tanks
An off loading manifold will have multiple headers and slope toward the pump suction. The minimum size of this manifold will be .
8in
Which component protects the hose from damage due to direct sunlight ?
permanent hose rack
In a pump room the exhaust fan inlets are located approximately _____ above the floor ?
6 inches
The Master pump control panel must be in the ____ position to allow you to automatically energize the pump from the fill stand ?
Auto
Which loading equipment component prevents an operator from putting fuel into the wrong refueling truck ?
Single point nozzl3e
What is the purpose of the Scully vehicle grounding system ?
Max safety , electric protection
The hoses used at Scully equipped fill stands will be the _____ type hoses.
API 529 type
When hydrostatically testing a hose you should close the water supply valve on the unit to prevent ?
Pressure h20 supply
A _____ inch band on each end of the hose will indicate hose slippage.
2 inch
The pressure required when hydrostatically testing a hose is how much ?
20 psi
wHICH TYPE DRY BREAK WILL ALLOW PRODUCT LOSS ?
Single point
Which dry break coupler is used to fill aircraft ?
Single point
Which is the most widely used dry break connection ?
lug less adapter
What tool do you use to depress interlock platE ?
interlock springs
How many ball bearing are in the CLA VALVE single point nozzle ?
50
What must you do to make sure that the ball plug does not back out ?
thread locking
After replaceing the ball bearing what must you visually inspect for ?
Nose seal
What is the normal capacity of a storage tank for mogas or diesel
10,000 gallons
The by pass valve on a MOGAS dispensing unit maintains discharge pressure of _____ psi when the pump is running
22 psi
What component on a dispensing unit maintains a full column of fuel in the suction line keeping the pump primed ?
foot valve
The pressure relief in a dispensing unit will relieve thermal expansion at what PSI
40 psi
The Vehicle Identification Link is used to ?
initiate activation of fuel disposer
When would the manual override switch in the terminal box be accessed on the pedestal ?
maintenece performing
How many times can the memory chip be encoded or be revised by fuels manager ?
10,000
Operational inspections are very important when it comes to _____ maintenance ?
preventitive
What could be the possible problem if you hear excessive noise or see vibration ?
loose pulley
What could be the possible problem if the computer register numbers turn while pumping against a deadhead ?
all pipe connections and gaskets are tight
What could be the possible problem if you are venting air continuously ?
empty tank or leak in suction line
How do you ensure smooth turning of register numbers ?
pump fuel into prover can
What could be a reason for the pump sticking ?
foreign matter , ice , rust
IF the lip seal pump shaft is leaking what should you replace ?
replace packing
What can cause the pump to stall comnpletely ?
bypass valve failing to open
How can you be sure of your dispensers maintenance requirements ?
manufacturer manual
What could cause the fule not to flow to the measuring unit ?
break in suction
How often do we calibrate dispenser meters ?
once a yr , whenever maintenance
Who calibrates the prover can ?
PMEL /depo measure and weights
What does it mean when you read below zero on the prover can ?
over reading
Why should you ensure that the nozzle is in contact with the prover can during filling ?
static spark
Each hole on the calibration wheel is _________ inches ?
2/3 cubic inch
On what service station component would you check for rust and corrosion, and O ring ?
Pump
A _____ is provided on the suction side of the pumping unit to remove foregn particles from the incoming liquid ?
Strainer
Which type of service station leak detection will detect vapor that comes from inside the buried double wall piping ?
Piping
IF vapor probes come in contact with liquids what does the manufacturer normally recommend ?
replacement
What set forth statutory requirements for acquisition of alternate fuel vehicles by federal agencies ?
EPAct
which agency governs the dryness required at automotive CNG stations ?
SAE
What vehicles were Not exempt from alt fuel requirements
vehicles lower than 8500 lbs
which agency governs dryness reuired at automotive CNG stations
Society automotive Engineers