- Front
- Back
HOW MANY DAMAGE CONTROL REPAIR LOCKERS ARE THERE? |
3 |
|
WHERE ARE THE DAMAGE CONTROL LOCKERS LOCATED? |
CREWS MESS, AUXILIARY MACHINE ROOM, AND ENGINE ROOM |
|
WHAT TEMPERATURE CAN FIRES REACH? |
2000 F |
|
WHAT WILL REPLACE THE FFE? |
FPG |
|
THE FFE ENSAMBLE CONSISTS OF WHAT? |
COVERALLS, ANTIFLASH HOOD, GLOVES, BOOTS, AND SCBA |
|
HOW MANY LAYERS ARE THERE TO THE FFE? |
3 |
|
HOW MANY STEAM PROTECTIVE ENSAMBLES ARE ON BOARD THE SUBMARINE? |
5 |
|
HOW MANY STEAM PROTECTIVE ENSAMBLES ARE USED FOR TRAINING AND EMERGENCY USE? |
3 FOR EMERGENCY, 2 FOR TRAINING |
|
WHAT DESIGNATES THE SPE FOR TRAINING? |
MARKED WITH ARED X |
|
WHAT ARE THE COMPONENTS FOR A SPE? |
VPC, FPG, STEAM HOOD, GLOVES, HOOD, SCBA |
|
WHAT IS THE PURPOSE OF THE VPC |
TO PROTECT FROM THE HIGH HEAT OF STEAM |
|
WHAT DOES A FPG CONSIST OF? |
COVERALL WITH REMOVABLE LINER, COMPRISED OF MOISTURE BARRIER AND THERMAL LINER |
|
HOW IS THE SCBA WORN WHILE IN A SPE? |
OVER THE FPG AND UNDER THE VPC |
|
WHAT IS A SCBA? |
A POSITIVE PRESSURE OPEN CIRCUIT SYSTEM THAT PROVIDES 30 MINS OF PROTECTION |
|
WHAT ARE THE 4 CLASSIFICATIONS OF FIRE AND WHAT DETERMINES EACH CLASSIFICATION? |
ALPHA- ANYTHING THAT MAKES AN ASH
BRAVO-LUBE OIL, GASOLINE CHARLIE-ELECTRIONICS DELTA- PYROTECHNICS |
|
WHAT IS AT EACH FIREHOSE LOCATION? |
2-25FT 1-1/2" HOSES, VARI-NOZZLE, 2 SPANNER WRENCHES, TRIM AND DISCHARGE MAIN VALVE |
|
HOW MANY FIRE STATION ARE THERE? |
8 |
|
WHERE ARE THE FIREHOSE STATIONS LOCATED? |
4 FORWARD FORWARD COMPARTMENT 2 TORPEDO ROOM AUX MACHINE ROOM 4 IN ENGINE ROOM UPPER LEVEL PORT UPPER LEVEL AFT TG LUBE OIL BAY MAIN SEAWATER BAY |
|
WHERE ARE THE 2 ADDITIONAL 25FT HOSES LOCATED? |
TD-36, TD-40 |
|
WHAT IS THE NFTI? |
INFRARED CAMERA DESIGNED TO LOCATE HOTSPOTS |
|
HOW LONG IS PRIMARY AND SECONDARY POWER FOR THE NFTI? |
PRIMARY-4.85 HOURS SECONDARY-3.05 HOURS |
|
WHERE IS THE SUBMERSIBLE PUMP STORED? |
IN EACH DAMAGE CONROL STATION |
|
AT WHAT TEMPERATURE DOES THE DEEP FAT FRYER DE-ENERGIZE? |
460F |
|
HOW LONG IS THE NON-COLLAPISBLE SUCTION HOSE AND COLLAPSIBLE DISCHARGE HOSE? |
SUCTION-10FT DISCHARGE-50FT |
|
WHAT ARE THE 2 COMPARTMENT PRESSURIZATION SYSTEMS? |
PRESSURIZATION SYSTEM, COMPARTMENT SALVAGE |
|
WHERE DOES THE COMPARTMENT PRESSURIZATION SYSTEM RECEIVE ITS AIR? |
AIR BANK #3 |
|
WHAT DO YOU SHUT OFF BEFORE PRESSURIZATION |
HP AIR SYSTEM, OXYGEN GENERATOR, CO2 SCRUBBER, AND COMPARTMENT VENTALIATIONVALVES |
|
WHAT ARE THE PSI IN ENGINE ROOM AND FORWARD COMPARTMENT BEFORE PRESURIZATION? |
17 PSI- ENGINE ROOM 8 PSI- FORWARD COMPARTMENT |
|
WHO CAN ORDER THE INITIATION OF PRESSURIZATION? |
O.O.D |
|
EAB IS SUPPLIED WITH WHAT PRESSURE AIR? |
100 PSI |
|
WHERE IS THE EAB LOCATED? |
WATCH STATIONS, LIVING AREAS, MAIN PASSAGEWAYS NO MORE THEN 20FT APART AND WITHIN 8 FT OF WATERTIGHT DOORS |
|
HOW ARE EABs IDENTIFIED? |
TRIANGLE MARKERS-POINT IN DIRECTION RECTANGLE-MEANS OVERHEAD |
|
HOW LONG IS THE EAB HOSE |
STANDARD 8 FT MAY CONTAIN 25 FT |
|
AFFF IS USED FOR WHAT TYPE OF FIRES |
B, MAY BE USED FOR A |
|
CO2 IS USED FOR WHAT TYPE OF FIRES? |
C, AND A |
|
PKP IS USED ON WHICH TYPE OF FIRES? |
B |
|
HOW MANY SIZES DOES THE SCBA FACEMASK COME IN? |
3 |
|
WHAT ARE THE SIZES AND COLORS OF THE SCBA FACEMASK? |
SMALL-GREEN LARGE-BLACK EXTRA LARGE-RED |
|
WHAT IS THE PRESSURE OF A FULLY CHARGED AIR CYLINDER? |
4500 PSI |
|
WHAT ARE THE 2 TYPES OF COMPOSITE CYLINDERS? |
FIBERGLASS, AND CARBON |
|
DESCRIBE THE FIBERGLASS CYLINDER |
YELLOW, 16-26 LBS |
|
DESCRIBE THE CARBON CYLINDER |
SILVER, ALUMINUM SHEL, 12-22 LBS |
|
WHAT DOES THE 1ST STAGE REGULATOR CONSIST OF? |
PRESSURE REDUCER, HP HOSE, AND PRESSURE RELIEF VALVE |
|
WHAT DOES THE SECOND STAGE REGULATOR CONSIST OF? |
EZ-FLO, HOSE COUPLING, AIR SAVER SWITCH, PURGE VALVE, LATCH MECHANISM, VIBRALERT |
|
WHAT DOES THE SEIE STOWAGE VALISE CONSIST OF? |
MK10 ESCAPE SUIT, INNER THERMAL SUIT, GAS INFLATED LIFE RAFT |
|
MK10 CONTAINS WHAT? |
POLYURETHANE COATED NYLON, INFLATABLE STOLE, ACCENT HOOD, WATERPROOF SLIDING FASTNER, INNER FOAM HOOD FOR THERMAL PROTECTION |
|
NAME THE ACCESSORIES FOR THE MK10 AND WHERE THEY ARE LOCATED |
SURVIVAL AIDS POCKET-FRONT LEFT LEG NOSE CLIP-SLIDING FASTNER WHISTLE- STOLE SPRAY SHEILD- INNER FOAM HOOD |
|
WHERE IS THE LIFE RAFT LOCATED? |
LEFT TORSO |
|
WHAT IS USED TO DETECT THE PRESENCE OF HYDROGEN IN CLOSED SPACES? |
B COMBUSTIBLE GAS INDICATOR |
|
WHAT IS USED TO DETECT THE PRESENCE OF GAS AND OTHER MIXES? |
E COMBUSTIBLE GAS INDICATOR |
|
WHAT IS USED TO DETECT LOW CONCENTRATIONS OF VARIOUS GASES AND VAPORS? |
DREAGER MULTI- GAS DECTOR |
|
HOW MANY DAMAGE CONTROL KITS ARE THERE AND WHERE ARE THEY LOCATED? |
3 IN EACH DC REPAIR LOCKER |
|
WHAT MAKES UP A DC KIT |
TOOL ROLL, BANDIT KITS, DC MATERIAL BAG |
|
WHAT IS ALL PURPOSE AND CONATINS MATERIALS THAT CAN BE USED TO PATCH RUPTURES IN LOW PRESSURE PIPING? |
DC MATERIAL BAG |
|
WHAT IS IN A DC MATERIAL BAG |
METAL WIRE SPOOL, WOODEN PLUGS, RUBBER SHEETS, SPOOLED TWINE, AND LEAD SHEETS MAY CONTAIN TARRED MARLINE, STEEL WIRE |
|
WHAT IS IN EACH BANDIT KIT |
CHAIN WRENCH, KEVLAR GLOVES, STEEL STRONG BACKS, STEEL STRAPPING, STRAPPING BUCKLES, AND BANDIT TOOL |
|
WHAT ARE THE DIMENSIONS OF STEEL STRONG BACKS? |
3/16" THICK 4" WIDE 8"LONG` |
|
WHAT ARE COLOR AND NUMBER CODES WITH SIZES? |
2-RED- 1.5" 3-BLUE-2.5"~3" 4-YELLOW-3.5"~4" |
|
WHAT MUST YOU HAVE TO REPAIR A RUPTURE? |
2 PEOPLE, GLOVES, AND APPROPRIATE TOOLS |