• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/27

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

27 Cards in this Set

  • Front
  • Back

Backplate

Made from high strength polymers, it is light weight, strong & durable


Has good resistance & anti-static qualitites


Easy to clean


Moulded skelton design


Orthppedically & ergonomically designed


Carry handle for ease of transformation


Designed to be worn like a burgen


Harness is adjustable by red buttons

Cylinder retaining strap

Two piece cylinder strap


Metal clip


Adjustable


Do not over tighten

Harness

Paddedmon pressureoints for comfort


Made from synthetic materials kevlar & Normex mix


Heat & flame retardant webbing


Adjustable shoulder straps


Designed to be worn like a burgen for maximum comfort


Rescue strap grab handle


Pivoting & adjustable height waist belt for wearer comfort


Trident type buckles

Harness adjustment

Adjustable harness lumbar support


Supports diverse user profile


Push red buttons together to select setting & then release buttons


Ensure setting is secure


4 positions xl, l, m, s

Cylinder info

Keep grease away from the valve


Serviced when needed or when cylindr is tested


Duration


Full 46 min


Working 36 min


Safety margin (Time of whistle) 10min


Historically based on a consumption rate of 40l/min


Could be 40-72% greater than this figure depending on work rate

Cylinder connector

Chrome plated marine quality brass - so it doesnt spark


Tubular stainless steel sintered 60 micron filter


Nitrile o ring


Quick fit push fit connection


Grolsh style cylinder restraining clip

Cylinder valve

Spring loaded plastic ratchet hand wheel (pull out to tighten)


2.5 turns fully open/closed


Chrome plated marine quality brass


Straight thread


Quick fit connector


5" copper anti debris tube

Ba computer (BAC)

Rovides audible sounds for ADSU & LPWD


Visual LED warning lights


Monitors air pressure but has no influence on the supply of air


Hold 160 hours of rolling data


Intrinsically safe


Sounder attached

Regulator unit

Relief valve operates at 12-14 bar


25 LPM choke screw to gauge


Security cap (anti-tamper valve)


60 micron sintred stainless filter


Working pressure maximum 10.5 bar in the medium hose

Medium pressure hose

Supplies air to face mask


Working pressure 18 bar


Test pressure 36 bar


Burst pressure 72 bar - 7.5 bar to breathing valve


Teflon inner


Wrapped fibre middle


Anti-static outer


Chemically bonded


Braided polyester

High pressure hose

Supplies air to DDU & gauge assembly


Working pressure 300 bar


Test pressure 600 bar


Burst pressure 900 bar


Stainless stell braided middle


Tefzel inner sheath


Estane outer cover

DDU & Gauge

Digital display unit (accurate)


Large digital display


Black scroll button on side


Red ADSU manual activation button


Red & amber warning lights


BAC battery indicator


Estimated turn around pressure (ETAP)


Light function



Bourdon tube gauge & pinion type gauge


Stainless stell wiyh neoprene rubber shroud


Photo luminescent face


Markings at 350, 300, 250, 200, 150, 100, 50 & 0


Safety features


Rubber outer shroud for protection


3mm perspex anti-shatter face


Blow out disc on the back

Audible warning device (whistle)

Provides an audible warning to indicate low cylinder pressure


Activates whenressure is dowm to 65 bar +/- 5 bar


Sounds down to 0


Cylinder air only, consumption 2 lpm

Breathing valve

Plugn in demand type


Vistamid reinforced plastic


Lung governed


Two channel air flow


Ambient air hatch


Purge byass feature, up to 100 lpm


Once operated will maintain +ve pressure within the face mask


Sensing port on left


O-ring seal


Supplies 450 lpm

QS S TYpe Mask

S type mask


Polycarbonate visor - grade 1 impact resistant


Spectacle insert lugs


Inner mask - orinasal


Demister ports


2 x non return (mushroom) valves


Exhalation valve


Ambient air hatch - store in the closed position


Wide single reflex seal


Vistamid plastic


Stqinless steel speech diagram


5 point head harness


5-11 bar air supply


Exhalation valve


Head up display


Spirocom unit


Chin position locator in mask


Enaure head harness is level & straight (buddy check)

Spirocom

Mode


Channel LCD display


PTT - push to talk


Volume / channle selector


Speaker arm

HUD LEDs

HUD - head up display


Series of LEDs - 4 on left, 2 on right


Supplements DDU & gauge - ideal for moisy environments



Right LEDs


Flashing amber LED - low battery warning


ADSU pre alert - red flashing light


ADSU activated - Red light lit



Left LEDs


300-240 bar green, amber, amber


239-150 bar amber, amber


149-100 bar amber, flashing red


99-66 bar flashing red


65-0 bar red lit

ETAP

Estimated turn around pressure


Cylinder contents + safety marhin ÷ 2


HUD active lights flash red for 10 seconds


DDU backlight turns red & flashes for 10 seconds


BAC LEDs flash red


Audible beep

ADSU

Removing the key from the DDU will operate tone & an amber lightnto inform wearer that unit is functioning correctly (BAECO check)


Lack of movement for 30 seconds will cause a 10 second pre-alarm, if no movement unit will lock into full alarm - sensor in DDU


Manual operator - push red button on top of the DDU


Key & tally


95db


Manual ADSU actovatoon button


Cam only be silenced with key


ADSU - warning lights are fitted to the DDU, BAC, HUD


Red flashing - pre alert HUD


Solid red -full ADSU alarm


Damp cloth to clean

Personal line

Attached to the harness


Stored in a pouch


6m total length - 1.25m & 4.75m


Tenax clip


D ring


Karabiner

Cable cutters

Stored in a pouch on waist belt


Blades up


Very sharp


Safety lock


Line stored hap-hazardly


Ip65 ingress protection rating


Insulated to 1000v


Easily removed from pouch

Ba lamp

Technical bulletin 1/97 requires a lamp to be provided for the use of breathing apparatus


To fulfill CFRS issues every operational member of staff with a personal issue tourch/lamp


Tb 1/97 is very clear that when testong the BA set the lamp must be tested and recorded in the log book

Air flow

Airs compressed in cylinder


Open valve


Air flows into BAC


BAC seperatedninto medium and high pressure


Medium knocked down by regulator to atmosphere pressure


Breathing valve


Facemask


Orinasal


Mushroom valves


Co2 out exhalation valve


High pressure to DDU

Duration

Full duration


Respiration protection from the moment the cylinder valve is open untilnexhausted (300 -0 bar)



Working duration


Respiratory protection from the moment the cylinder valve is opened until the moment the low pressure warning whistle starts to operate (300 - safety margin 65 +/- 5)



Safety margin


The period during which the low pressure warning whistle operates from 65 +/- 5 bar to 0

Work out there time of whistle at ECO

Dorset calculator

Monthly test

General - plus wear / test for 50 bar

Cylinder

Plastic liner, carbon fibre wrapped, resin coated


6.7 litre water capacity


Weight 9kg


1800 litre capacity


Charged to 300 bar


Numbered and bar coded


Rubber impact absorber at each end pressure indicator


Pressure indicator


Pull out ratchet hand wheel (prevents accidental closing)


Quick fit push connection