67 Cards in this Set

  • Front
  • Back
IDG'S SUPPLY POWER TO
DIRECTLY TO THE 2 AC TRANSFER BUSSES
IDG'S CONTROLLED BY
GENERATOR CIRCUIT BREAKER, GCB
TRANSFER BUSSES CONNECTED BY
BY A BUS TIE & TWO BUS TIE BRKS
THE TRANSFER BUSSES SUPPLY POWER TO
TO THE REMAINING AC BUSSES AND THE TR'S
MAIN BAT ENERGISES WHAT WHEN A/C PWR NOT AVAIL
THE HOT BAT BUS & SWITCHED HOT BAT BUS WHEN A/C PWR IS NOT AVAILABLE
IN EMERGENCY THE MAIN BAT ALSO SUPPLIES
SUPPLIES BAT BUS, DC STBY BUS AND THE AC STBY BUS VIA AN INVERTER
AUX BAT USED WHEN
ONLY AS EMERGENCY PWR SOURCE FOR STBY BUS VIA AN INVERTER
BAT CHGR USE
MAINT BAT CHARGE. ALSO THE NML PWR SOURCE FOR THE HOT BAT & SWITCHED HOT BAT BUSSES
HOW MANY BTB'S
2 BETWEEN THE AC TRANSFER BUSSES
HOW MANY GCB'S
2 BETWEEN EACH IDG AND ITS TRANSFER BUS
HOW MANY TR'S AND GIVE SOURCES OF POWER
3 TR'S
-TR1 FROM AC TRANS BUS 1
-TR2 FROM AC TRANS BUS 2
-TR3 FROM EITHER AC TRANS 1 OR 2
GND SERV SWITCH LETS YOU CONNECT
CONNECT THE GND SERV BUSSES 1 & 2, THE BAT CHARGER, AC STBY BUS VIA BAT CHRG AND INVERTER
-ALSO POWER TO THE HOT BAT BUS, SW HOT BB, THE BAT BUS AND THE DC STBY BUS
2 BASIC RULES OF ELECTRICAL PWR ON THE 737
AC POWER SOURCE CANNOT BE OPERATED IN 1-PARALLEL-ONLY ONE SOURCE OF AC PWR CAN BE CONNECTED TO A TRANS BUS AT A TIME
2-IF A 2ND PWR SOURCE IS CONNECTED TO A TRANS BUS THE FIRST SOURCE IS AUTOMATICALLY DISCONNECTED
WHAT ELECTRICAL CNTLS ARE ON THE OVHD PANEL
1-AC/DC METERING PANEL
2-GEN DRIVE & STBY PWR PANEL
3-GND PWR & BUS SWITCH PANEL
THE CB PANELS ARE WHERE
P6-BEHIND F/O SEAT
P18 BEHIND CAPT SEAT
AC PWR SYST MADE UP OF
1-TWO TRANSFER BUSSES
2-TWO MAIN BUSSES
3-TWO GALLEY BUSSES
4-ONE AC STBY BUS
5-TWO GND SERV BUSSES
IF 2 PWR SOURCES CONNECTED AT THE SAME TIME
BTB'S OPEN TO PREVENT PARALLEL OPS OF THE IDGS
IF ONLY ONE PWR SOURCE
THE BTB'S CLOSE TO SUPPLE PWR TO BOTH TRANSFER BUSSES.
TRANSFER
BUS OFF LT MEANS
TRANSFER BUS IS NOT ENERGIZED
SOURCE OFF LT MEANS
TELLS YOU NO PWR SOURCE IS SELECTED TO ENERGIZE THE TRANSFER BUS
ALSO ILLUMINATES WHEN THE GEN SW IS PUT ON AND THE RELATED GEN DOES NOT CONNECT AND SUPPLY PWR TO THE TRANSF BUS
GEN OFF BUS LT
TELLS YOU THE TRANSF BUS IS NOT SUPPLIED POWER FROM THE RELATED IDG
APU GEN OFF BUS LT
SHOWS THE APU IS AVAILABLE BUT DOES NOT SUPPLY PWR TO THE BUS. THE LT EXT WHEN THE APU GEN IS CONNECTED TO A BUS
GRD POWER AVAILABLE LIGHT
ILLUMINATES WHEN GRND PWR OF GOOD QUALITY IS CONNECTED TO THE PLANE. LT DOES NOT EXT AFTER GND PWR IS CONNECTED TO THE PLANE
WHEN GND PWR CONNECTED THE TRANS BUS OFF & SOURCE OFF LTS SHOW WHAT
THEY ARE EXTINGUISHED
IF ON GRND PWR AND YOU SELECT THE APU 1 SWITCH ON
THE APU DISCONNECTS THE GND PWR FM THE TIE BUS
THE SOURCE OFF LT ILLUMS BECAUSE THE MANUALLY SELECTED SOURCE HAS BEEN AUTOMATICALLY DISCONNECTED
WHEN ENG 2 RUNNING & MOVING GEN 2 TO ON
THE BTB OPENS, THE No2 IDG SUPPLIES PWR TO THE TRANSFER BUS No2
THE OTHER TRANSF BUS CONTINUES TO BE ENERGISED BY THE APU OR GND PWR IF CONNECTED
BOTH ENGINES RUNNING THE APU OFF GEN LT ILLUMS WHEN
THE APU GEN IS NO LONGER CONNECTED TO A BUS
NORMAL AC INDICATION IS
NML VOLTS 115V +/- 5V
NML FREQ 400 +/- 10cps
AMPS CHANGE WITH LOAD
USE AC METER SELECTOR
AUTOMATIC GEN ONLINE FUNCTIONS HOW
IF APU STILL SUPPLYING PWR THEN FAILS OR IS SHUT DOWN THEN THE IDG AUTOMATICALLY CONNECTS TO THE BUSSES
WHAT ARE THE CONDITIONS FOR AUTOMATIC GEN ONLINE
1-ONLY IN FLT
2-ONLY ONE TIME PER FLIGHT
3-IDG'S NOT CONNECTED TO BUSSES
4-APU FAILS OR IS SHUT DOWN AFTER TAKE-OFF
IF ONE PWR SOURCE IS LOST IN FLIGHT
THE BTBs CLOSE & PWR IS SUPPLIED FROM A SERVICEABLE SOURCE
ELEC SYST AUTOMATICALLY LOAD SHEDS
WHAT IS THE ORDER OF THE LOAD SHEDDING
-GALLEY BUSSES FIRST
-THEN MAIN AC BUSSES ARE DE-ENERGIZED ONE AT A TIME TILL LOAD FALL TO LESS THAN SYST LIMIT
-WHEN PWR IS AVAILABLE BUSSES ARE ENERGIZED AGAIN
-
DURING TAXI IN CAN YOU CONNECT THE APU GEN
YES. AFTER THE APU GEN OFF BUS LTS ILLUM
TRs SUPPLY WHAT VOLTAGE
28V DC PWR
WHAT VOLTAGE DO THE TRs CHANGE
CHANGE 115V AC FM THE TRANS BUSSES TO 28V DC FOR THE DC BUSSES
TR1 PWRD FROM
TR2 PWRD FROM
TR3 PWRD FROM
TR1-PWRD FM TRANS Bus1
TR2- FROM TRANS BUS 2
TR3- NML SOURCE IS TRANS BUS 2 BUT TRANS BUS1 CAN ALSO BE USED
TR3 ALSO KNOWN AS
THE AUX PWR SOURCE IF TR1 OR TR2 FAILS
TR3 IS THE NML SOURCE OF PWR FOR THE BAT BUS
IF ONE TR FAILS
THE REMAINING CAN SUPPLY PWR FOR THE DC LOAD
CROSS BUS TIE RELAY IS
THE DC BUSSES ARE CONNECTED BY THIS
WHEN DOES THE CROSS BUS TIE RELAY OPEN
AUTOMATICALLY ON GLIDE SLOPE CAPTURE
ALSO WHEN BUS TRANSFER SW PUT TO OFF
WHAT DOES THE OPENING OF THE CROSS BUS TIE RELAY DO
OPENS TO ISOLATE THE NAVIGATION RECEIVERS & FLT CNTL COMPUTERS
THIS PREVENTS REMOVAL OF ALL APPR INFO BECAUSE OF ONLY 1 ELECTRICAL FAILURE
IF NML PWR TO DC BUSSES FAILS WHAT SOURCE IS USED
BATTERIES ARE THE EMERGENCY SOURCE 2X24V NICAD
EMERGENCY SOURCE OF PWR FM BAT IS FOR WHICH BUSSES
1-STATIC INV
2-DC STBY BUS
3-BAT BUS
4-HOT BAT BUS
5-SW HOT BAT BUS
SW HOT BAT BUS IS CNTL'D BY
CONTROLLED BY THE BAT SW
AUTOMATIC BAT CHRGR GETS PWR FM
AC GND SERV BUS2 WHEN PWR AVAIL
AUX BAT CHRGR SUPPLIED FROM
PWR FM AC TRANS BUS 1 AND GND SERV BUS 1
NML DC IND IS
26.0+/-4V, THE AMPS VARY WITH LOAD
USE OF STBY PWR SYSTEMS
SUPPLY AC & DC TO IMPORTANT ELECTRICAL COMPONENTS WHEN NML AC PWR NOT AVAIL FM ENGINES OR APU
POWER FOR STBY SYSTEMS IS FROM
BATTERIES & A STATIC INVERTER
STBY SYSTEMS SUPPLY PWR TO WHICH BUSES
1-AC STBY BUS
2-HOT BAT BUS
3-DC STBY BUS
4-BAT BUS
5-SW HOT BAT BUS
BATTERY PWR IS SUPPLIED FOR HOW LONG IF NO OTHER SOURCE IS AVAILABLE
60 MINS
WHAT HAPPENS IF ALL AC PWR IS REMOVED
THE STBY PWR CONTROL UNIT AUTOMATICALLY CHANGES THE STBY SYST TO BAT PWR. THE CHANGE CAN TAKE PLACE ON THE GND OR IN THE AIR.
IF THERE'S A FAILURE IN GEN1 AND BUS TRANS SW IS OFF
THE TRANS BUS 1 AND ITS RELATED BUSSES ARE DE-ENERGISED
ON THE GRND OR IN FLT IF APU IS THE ONLY ELECTRICAL SOURCE
BUS TRANS OFF POSITION ARMS EACH BUS TIE BREAKER TO OPEN IF ITS RELATED APU GEN SW IS SET TO OFF
IF APU GEN SW2 IS SET TO OFF THEN
TRANS BUS 2 & ITS RELATED BUSSES ARE DE-ENERGISED BY THE No2 APU GEN SW
BOTH GENS DISCONNECTED WHAT HAPPENS TO THE AUTOPILOT AND WHAT ANNUNS DO YOU GET
DISENGAGES AND CANNOT BE ENGAGED UNTIL A GEN IS AVAILABLE
ALSO GET THE MC & ELEC SYST ANNUN ILLUM, THE TRANS BUS OFF, SOURCE OFF & GEN OFF BUS LTS FOR BOTH GENS
IF SOURCE OFF LIGHT REMAINS ILLUM
IT'S NECESSARY TO PREVENT HIGH ELEC LOADS BEFORE A GEN IS CONNECTED TO THE SYSTEM (IE BUS TRANS OFF, ELEC HYD PUMPS OFF)
ACTIONS BOTH GENS DISCONNECTED
1-TRY TO RECONNECT IF FAILS
2-BUS TRANS SW OFF
3-TURN OFF ELEC HYD PUMP
4-IF AVAILABLE START APU WITH BUS TRANS SW OFF
5-CONNECT APU GENS 1 AT A TIME
6-MOVE BUS TRANS TO AUTO
7-MOVE APU GEN 2 TO ON TO EXT SOURCE OFF LT
8-TURN ON ELC HYD PUMPS ONE AT A TIME
IF 2 SOURCE OFF LIGHTS FAIL TO EXT
-STBY SYST ON BAT PWR
-LAND AT NRST SUITABLE AIRPORT
IF A GEN FAILS TO RECONNECT IE SOURCE OFF LT STAYS ON ACTIONS
-START THE APU IF AVAIL
-CONNECT THE APU GEN
ACTIONS FOR TRANSFER BUS OFF LT ILLUM
SAME AS FOR SOURCE OFF LT-
START APU
CONNECT APU GEN
STANDBY PWR OFF LT ILLUMINATED
ACTIONS
PWR IS NOT AVAIL TO SOME PART OF THE STBY PWR SYST
-MOVE STANDBY SW TO BAT
(BAT SUPPLIES THE STBY SYST)
WHEN DOES DRIVE LT ILLUM
WHEN THE IDG HAS LOW OIL PRESS OR
THE ENGINE IS NOT RUNNING
THE DISCONNECT SWITCH LETS YOU
DISCONNECT AN IDG FROM ITS ENGINE DURING A NON-NORMAL SITUATION.
-CAN ONLY BE RECONNECTED ON THE GROUND BY MAINTENANCE
BAT DISCHARGE LT ILLUM
BAT SW IS ON & BATT DISCH IS LARGE
ALSO DURING APU START ON BAT PWR ITS NML FOR THE LT TO ILLUM FOR A SHORT TIME THEN EXT
TR UNIT LT ILLUM ON THE GROUND
A TR HAS FAILED
IE TR1 , TR2, OR TR3
TR UNIT LT ILLUM IN THE AIR
WHEN ONE OR TWO TRs HAVE FAILED IE TR1 OR TR2 & TR3
ELEC LT ILLUM
TELLS YOU THERE IS A FAILURE IN THE DC OR STBY PWR SYST. ONLY ILLUM ON THE GROUND