Describe the voltage and amps of battery

24v, 42ampere hour sealed lead acid

What generators supply power

30 volt regulated to 28.25volts, 250ampere starter-generatorsw

Where is the battery located

Right wing centre section

Where is the battery switch

Left pilot sub panel behind gang bar

What is the isolation limiter rated to ?

325 amps

What is the isolation limiter rated to ?

325 amps

How much could the starter draw generator during engine start.

Initially 1,100amps reducing to 300 approaching 20% N1

At what percentage will the engine start to drive the generator? what percentage can the generator be switched on at ?

Drives at 35%, April 70% in high idle switch on generator

Where are the generator switches

Behind the gang bar left side sub panel

How do you switch on the generator

Hold in the up (reset position) for Minimum 1 second then release to on (middle) position

Ground power receptor position?

Right wing outboard of the nacelle

What does the generator load meter read in?

Percentage of 250amps eg 10% = 25 amps

At what percentage will the engine start to drive the generator? what percentage can the generator be switched on at ?

Drives at 35%, April 70% in high idle switch on generator

Where are the generator switches

Behind the gang bar left side sub panel

How do you switch on the generator

Hold in the up (reset position) for Minimum 1 second then release to on (middle) position

Ground power receptor position?

Right wing outboard of the nacelle

What does the generator load meter read in?

Percentage of 250amps eg 10% = 25 amps

Procedure for connecting ground power,

1Check source polarity


2BATT switch to On


3 GPU Voltage less than 32

How many volta must the battery have prior to usage of GPU

20v

How many volta must the battery have prior to usage of GPU

20v

How do you switch off avionics before connecting ground power

Switch on battery, switch off avionics master, switch off individual avionics separately

Max voltage slowed to be supplied to battery

30v for no longer than 2 mins

How is each bus protected?

60 ampere current limiter


70 ampere reverse current diode


50 ampere circuit breaker

Inverters provide what? For what?

115v Ac at 400hz


26v AC at 400hz


For avionics and engine instruments

Inverters provide what? For what?

115v Ac at 400hz


26v AC at 400hz


For avionics and engine instruments

Max sustained Generator load limits

SL to 31,000ft - 100%


Above 31,000ft - 88%


Ground - 85%

Inverters provide what? For what?

115v Ac at 400hz


26v AC at 400hz


For avionics and engine instruments

Max sustained Generator load limits

SL to 31,000ft - 100%


Above 31,000ft - 88%


Ground - 85%

Starter usage limitation

40s on 60s off


40s on 60s off


40s on 30 mins off