• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/14

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

14 Cards in this Set

  • Front
  • Back

If all power is lost, ADG deployed, which window will have heat?

Only the left side window. Its ran off the ESS Bus.

What happens during a fail-safe condition in the ADS probe heat system?

Heat will be applied to probes.

What is the max amount of operation time allowed for window and windshield heaters on ground?

3 minutes.

How many messages are displayed with probe heat off, on ground? In air?

On the ground, 2. In the air, 12.

When WING A/ICE is selected to NORM or STBY mode, what indicates the system is on and and the wing LE are heating up?

L HEAT and R HEAT lights on and a green WING A/ICE ON advisory message is displayed on the EICAS.

What are the indications of a successful wing anti-ice system test?

L HEAT and R HEAT lights illuminated on A/ICE panel, green WING A/ICE TEST OK advisory message and red WING OVHT message on EICAS, and the wing overheat aural alert.

What causes the green ON light on ANTI-ICE COWL switch to come on?

A pressure switch, downstream of the cowl anti-ice valve.

What is the difference in operation between the normal mode and stby mode of the wing anti-ice system?

The stand-by mode is a degraded mode of operation and the wing a/ice valves are directly controlled by a thermal switch

How is ice detection accomplished?

The frequency of the oscillator in the ice probe is reduced by the ice, which is sensed by a microprocessor.

With regards to enable logic of the Air Data Sensor heater controllers, when is probe heat enabled?

When DC power to the controller is lost/removed.

Selecting the TEST switch on the ANTI-ICE control panel top the WING position will:

Test the overheat and sufficient heat circuits of the wing anti-ice controller.

What is the function of the cowl anti- ice pressure switch?

Provides cowl anti-ice valve position to the data concentrator unit (DCU)

What is the purpose of the microswitch on any 10th or 14th stage bleed air valve?

To provide an indication when the


SOV is 8 degrees from the closed position.

Why should the windshield/ window heat be left off on the ground?

Because the windows are made of two layers with a soft inter-layer. Heaters installed in the inter layer can melt or burn the interlayer.