Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
48 Cards in this Set
- Front
- Back
C29 UWCA 1
|
Sample D75, Reduce C702
|
|
UWCA 2
|
Start w/ ~twice the aggregate needed
|
|
UWCA 3
|
Bring to oven dry condition
|
|
UWCA 4
|
Determine volume of bucket with water/glass plate
|
|
UWCA 5
|
Rodding (fill 1/3, tamp 25x, fill 2/3, tamp 25x penetrating, overfill, tamp 25x penetrating, rod off)
|
|
C127 Density, S.G. Abs 1
|
Sample D75, Reduce C702
|
|
C127 2
|
Use material retained on or above #4 sieve
|
|
C127 3
|
Determine mass needed by NMAS
|
|
C127 4
|
Take dry weight
|
|
C127 5
|
Submerge 24 hrs, take Wsubmerged
|
|
C127 6
|
Dry with damp towel, take Wssd
|
|
C131 - L.A. Abrasion 1
|
Sieve to obtain grading/test samples
|
|
C131 2
|
Use tables to select correct # of spheres with required mass
|
|
C131 3
|
Place sample and charge in machine
|
|
C131 4
|
Run test at 30 rev/min for 500 revs
|
|
C131 5
|
Sieve onto #12, % passing is % loss
|
|
C136 Sieve Analysis - 1
|
Reduce sample using mechanical splitter
|
|
C136 2
|
Determine sample size by NMAS
|
|
C136 3
|
Use SCDOT tests to determine sieves
|
|
C136 4
|
Run test in mechanical shaker for 15 minutes or until <1% is lost when shaken by hand
|
|
C136 5
|
Ensure that no sieve was overloaded
|
|
C136 6
|
Record mass on each sieve
|
|
D2041 Theoretical MSG and Density 1
|
Obtain appropriate sample size (if too large, work in stages)
|
|
D2041 2
|
Dry and record mass
|
|
D2041 3
|
Separate by hand
|
|
D2041 4
|
Cover sample completely in water in covered container
|
|
D2041 5
|
Attach to mechanical agitation device/remove air trapped in sample using vacuum pressure
|
|
D2041 6
|
Release pressure using bleeder valve
|
|
D2041 7
|
Determine submerged mass
|
|
D2041 8
|
Perform MSG calculations
|
|
D2726 Bulk Specific Gravity - 1
|
Use pills created
|
|
D2726 2
|
Record dry weight after pill cools
|
|
D2726 3
|
Submerge in water for 3-5 minutes, record submerged weight
|
|
D2726 4
|
Dry with damp towel and take Wssd
|
|
D4791 Flat and Elongated Particles 1
|
Determine needed mass for sample using NMAS
|
|
D4791 2
|
Use material retained on #4, reduce using C702 until 100 particles remain
|
|
D4791 3
|
Based on specs, use methods A and B and place create groups
|
|
D4791 4
|
Use test apparatus and correct ratios to test each rock and count results
|
|
D6307 Binder content using ignition test 1
|
Get sample with quartering method C702
|
|
D6307 2
|
Determine mass of sample by NMAS
|
|
D6307 3
|
Heat to 110 degrees celsius
|
|
D6307 4
|
Set ignition oven to 1000 degrees fahrenheit
|
|
D6307 5
|
Record mass of trays and catch pan
|
|
D6307 6
|
Distribute sample evenly across THREE trays
|
|
D6307 7
|
Record initial mass of setup
|
|
D6307 8
|
Set correction factor to zero and run test
|
|
D6307 9
|
Oven will auto stop when loss does not exceen .01% of mass for 3 minutes
|
|
D6307 10
|
Machine will give results, weight by hand to double check output
|