Enclosures part 3 Enclosures must be strong enough to.. |
Stand negative pressure |
|
Alex with flaps... |
Waited, on the inside |
|
Sufficient and suitable... |
Visual panels |
|
Baglock.. |
Three-stage facility for removing waste |
|
Negative pressure unit |
Negative pressure unit |
|
NPU Minimum of 8 air changes per hours for enclosures of.. |
120m³ or more |
|
Recommended 8 to... |
10 air changes per hour |
|
Area sizes below 120m³... |
At least 1000m³ per hour. |
|
Pre filter on... |
Inside of enclosure |
|
HEPA filter must be.. |
Outside of enclosure |
|
Site pre-filter away from airlock to ensure... |
Good thorough airflow |
|
Enclosure check Integrity of.. |
Enclosure inside and out |
|
Enclosure check Smoke test preferrably with.. |
Oil mist generator Witnessed and the proof |
|
Enclosure check Checklist 3 points.. |
Notices - waste disposal Decontamination unit - airlock Method statement |