  • Front
  • Back
SHUTOFF/EXT SW
Guarded 3 position SW
EXTNG- discharges ext agents into APU compartment
CLOSE - closes APU fuel shutoff and bleed valves
Disconnects APU gen from central DC bus
Deenergizes the APU control panel
FIRE warning light
Fire or overheat condition is sensed by fire detector
The red FIRE light illuminates and remains so until condition is eliminated
Fire detect INOP light
If gas is lost from detector loop the INOP light illuminates
Amber APU light on MAP
master CAUTION flashes
INOP light also come on during main fire system test
Bottle ABLE light
Illuminates only during test sequence means the bottle explosive firing circuits are intact
Fuel totalizer APU fuel consumption
Post mod 130 lb/ hr
APU starting
Min 22 volts
Max alt for start 20000
Speed 135-240 KIAS
Smell of fumes in a/c
Shut down bleed from APU
If APU is shut down and the APU master switch has been turned off
Do not turn switch back on for at least one minute
To prevent electrical transients affecting sensitive electronic equipment
Place Backup Batt switch to ARM position prior to APU start