DESIGN- MILL TOLERANCE FOR ROLLED AND WELDED PIPE

-0.010

NDE- MAXIMUM LENGTH OF CRACK, OR INCOMPLETE FUSION ALLOWED ON A NEW WELD

0"

FLANGES- TYPICAL FLANGE FACE FINISH

125-250 MICRO-INCH

FLANGES- WHEN MATING FLANGES, THE MAXIMUM AMOUNT OF UNPARALLEL ALLOWED


( PER DIAMETER OF FLANGE IN FEET )



1/16" PER FOOT

FLANGES- MAX OFFSET FOR BOLT-HOLES FOR MATING FLANGES

1/8"

WELDING- MAXIMUM ALLOWED SIZE OF OPEN DISCONTINUITY IN A BEND TEST

1/8"

NDE- MINIMUM DISTANCE BEYOND THE AREA TO BE EXAMINED TO CLEAN A PART WHEN PERFORMING A MT EXAMINATION

1"

NDE- MINIMUM DISTANCE BEYOND THE AREA TO BE EXAMINED TO CLEAN A PART WHEN PERFORMING A PT EXAMINATION

1"

REPAIRS- MINIMUM RADIUS OF INSERT PATCH

1"

NDE- MAX DIAMETER OF CML EXAM POINT FOR LINES GREATER THAN OR EQUAL TO 10 NPS

2"

NDE- MAX DIAMETER OF CML EXAM POINT FOR LINES LESS THAN 10 NPS

3"

PREHEAT ZONE- DISTANCE FOR START OF WELD

GREATER OF 3" OR 1.5 T (TIMES THICKNESS)

PWHT ZONE- MINIMUM WIDTH OF BAND

3 T ( TIMES THICKNESS)

NDE- MINIMUM LENGTH OF SPOT RT

6"

WELD QUALITY- MINIMUM WELD LENGTH WHEN QUALIFYING A WELDER WITH RT/UT USING A COUPON OR 1ST PRODUCTION WELD

6"

WELD QUALIFY- MINIMUM WELD LENGTH WHEN QUALIFYING A WELDING OPERATOR WITH RT/UT OF A TEST COUPON

6"

CORROSION- SOIL-TO-AIR AREA- DISTANCE IN AIR INTERFACE

6"

CORROSION- DISTANCE TO DIG WHEN INSPECTING FOR SOIL-TO-AIR CORROSION

6"-12"

NDE- DISTANCE OF EYE-TO-PART TO COUNT AS A VISUAL EXAM

6"-24"

CORROSION- SOIL-TO-AIR AREA- DISTANCE IN SOIL FROM INTERFACE

12"

NDE- MINIMUM UPSTREAM LIMIT OF INTENSIVE EXAMINATION OF INJECTION POINT CIRCUIT

12"

PWHT- MINIMUM OVERLAP FOR PWHT WHEN USING MULTIPLE HEATS

12"

WELD QUALIFY- MINIMUM WELD LENGTH WHEN QUALIFYING A WELDING OPERATOR WITH RT/UT OF FIRST PRODUCTION WELD

3'

UNDERGROUND- MINIMUM LENGTH OF BURIED PIPE TO EXPOSE WHEN EXCAVATING FOR INSPECTION

6'- 8'

REPAIRS- MAXIMUM SIZE OF FILLET WELD PATCH ON PIPE

1/2 DIAMETER

CIRCUITS- MINIMUM UPSTREAM LIMIT OF INJECTION POINT CIRCUIT

GREATER OF 12" OR 3 DIAMETER

NDE- MINIMUM DOWNSTREAM LIMIT OF INTENSIVE EXAMINATION OF INJECTION POINT CIRCIUT

10 DIAMETERS

CIRCUITS- MINIMUM DOWNSTREAM LIMIT OF INJECTION POINT CIRCUIT

LESSER OF: 1ST DIRECTION CHANGE + 25', OR


2ND DIRECTION CHANGE

LINEAR INDICATION

LENGTH IS LESS THAN OR EQUAL TOO 3 TIMES WIDTH