Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
22 Cards in this Set
- Front
- Back
How many fuel tanks does the airplane have?
|
2 integral tanks
|
|
Where is fuel tank temperature taken?
|
Left tank
|
|
What types of fuel pumps are in each wing?
|
Primary ejector pump
ACMP DCMP (right tank) 3 scavenger pumps |
|
What is the primary ejector pump?
|
Venturi pump with no moving parts and no electrical power used by the engine Powered by motive flow
|
|
What is the purpose of the ACMP?
|
Back-up pump in case of primary ejector pump failure
Engine start Crossfeed operations APU start |
|
What is the purpose of the DCMP?
|
Used for APU or engine start is AC power or the ACMP is not available.
|
|
What is the purpose of the scavenge pumps?
|
Maintains fuel level in the collector box
|
|
What pump(s) is used once an engine is started?
|
Associated primary ejector pump
|
|
What is the purpose of the collector box?
|
Keeps the fuel pumps submerged
Ensures constant fuel flow to the engine |
|
What is the surge/vent tank?
|
Collects fuel during wing-down maneuvers and returns it to the main tanks once the wings are level.
Equalizes tank pressure with atmosphere in flight and during refueling |
|
Can fuel be transferred from tank to tank? Can fuel be dumped overboard?
|
No
|
|
What happens when the crossfeed switch is selected to LOW 1?
|
Crossfeed valve is opened Commands the ACMP 2 to ON to provide fuel from the right tank to both engines
|
|
What is the only way to close the engine fuel shut off valve (SOV)?
|
Pull the associated engine fire extinguishing handle
|
|
When will the FUEL 1(2) LOW LEVEL EICAS be presented?
|
660 lbs of fuel remaining in the associated tank
|
|
What is the power source for a #1 AC pump? #2 AC pump?
|
AC BUS 1 AC ESS BUS
|
|
What is the fuel density?
|
6.768 lb/us gal
|
|
What does the OFF position of the fuel crossfeed selector knob do?
|
Closes the crossfeed valve
|
|
Can you refuel the airplane without APU/EXT power?
|
Yes
|
|
How would you check the fuel quantity if the electric fuel quantity indicator fails?
|
With the magnetic level indicators.
|
|
What would be the indication of a fuel imbalance?
|
An EICAS FUEL IMBALANCE caution is displayed when the imbalance equals or exceeds 800 lbs until the imbalance is reduced to 100 lbs.
|
|
Where would the fuel system indications and parameters be displayed?
|
On the Fuel Status page on the MFD and the EICAS.
|
|
What is the minimum fuel tank temperature
|
-40ºC
|