70 Cards in this Set
- Front
- Back
Max load before overload alarm will sound
|
5oolbs.
|
|
How do we ground aerial generators?
|
There is currently no way to ground aerial generators.
|
|
Formula for Watts
|
Volts x Amps
|
|
If you use a cord over ____ft you need to increase the gauge of the cord used.
|
100ft
|
|
12 gauge cord is rated at ____amps
|
20amps
|
|
14 gauge cord is rated at ____amps
|
15amps
|
|
True/False:
Each outlet is connected to a separate breaker. |
True
|
|
Name 4 safety factors to consider during aerial operations
|
- Fire building condition
- Angle/ location of apparatus - Wind/ weather conditions - Electrical lines/overhead obs |
|
Normal aerial hydraulic pressure
|
2500 psi
|
|
Maximum aerial hydraulic pressure
|
5000 psi
|
|
What is the jack shaft?
|
It is like the drive shaft but shorter. It drives the hydraulic pump.
|
|
What is the max speed with the interlock differential on?
|
15 mph
|
|
There are as many as ___ air tanks on aerials
|
6
|
|
5 considerations when placing outriggers
|
- look for firm and dry ground
- watch for manhole covers - underground parking lots - storm drains - elevated sidewalks |
|
Keep ladder a minimum of ____ft from power lines.
|
Keep ladder a minimum of 10ft from power lines.
|
|
What is the scrub surface?
|
Maximum area on the building that can be covered by the aerial.
|
|
difference between real height vs. rated height
|
The rated height includes the height of the truck. The real height can be shorter depending on how the ladder is placed in relation to the truck body.
|
|
When used for roof access the aerial should be extended ____ft above the roof.
|
When used for roof access the aerial should be extended 6 ft above the roof.
|
|
When possible, position the truck at what angle in relation to the fire building?
|
Position the truck at a right angle to the fire building.
|
|
How much water weight does a 500gpm master stream inject into a building every minute?
|
2 Tons
|
|
True/False
It is OK for personnel to go up on an aerial during a fire without an SCBA. |
False
|
|
Names some causes of stress on an aerial.
|
- Excessive angles - Wind reaction
- Non-parrallel positions -Improper operation - Length of extension - Heat exposure - Nozzle reaction - Impact w/building - Weight and movement - Improper stabilization |
|
Using the aerial in a position _________ to the chassis is the safest position.
|
Using the aerial in a position longitudinal to the chassis is the safest position.
|
|
What is the most stressful position for an aerial to be put in?
|
A low/right angle
|
|
How long of a run can you do with an electrical cord before you need to increase the gauge?
|
100'
|
|
number of cables used to control aerial.
|
2
|
|
safety factor of aerial ladder
|
8:1
|
|
Aerial apparatus operate at full capacity with a side slope of what?
|
0-3.5%
|
|
Aerial apparatus operate at 50% capacity with a side slope of what?
|
3.5 - 5.5%
|
|
what psi should ground be able to hold for outriggers to be safely placed?
|
75psi
|
|
TRADE |
Training resource and data exchange program |
|
Scrub surface |
Max area that can be covered |
|
Five floors or less Park ladder |
Outside of engine |
|
Five floors or more |
Park inside of engine |
|
Hey Ariel should be extended how many feet above wall/ parapet |
6ft |
|
What position applies the worst stress for Ariel's |
Right angle long & low ext. |
|
What is the best position for Ariel stress |
Inline/longitude to chassis |
|
2 groups of aerials |
Ariel & elevating platforms |
|
Ladders must have a rated vertical height of |
50ft |
|
Hydraulic system components (3) |
Hydraulic pump cylinders hydraulic motors( electric or mechanical are required) |
|
2 NFPA 1901 requirements |
2 or more ladder sections Constructed of metal, steel, heat treated aluminum |
|
Support beams are what type of construction |
Triangular truss construction |
|
Ladder rung specs |
14" apart on center 1 1/4" diameter 500lb minimum load 18" @ narrowest point |
|
What is a minimum rated capacity at the tip of the fly section fully extended |
250lbs |
|
Tfd Platform rated capacity |
1000 pounds in any position while flowing a 1000gpm |
|
TFD rated capacity for aerials |
500gpm and any position while flowing 1000gpm |
|
Aerials 110 feet or less must |
Rotate 90° fully elevated & extended In less than 120sec |
|
Safety aspects of platforms |
Leveling system 14sq ft floor space No opening greater then24" 2 gates below top railing 4 inch kick plate at floor level 1/4 drain in kick plate Heat protective Shield 75gpm water curtain 400 cu ft air systems for 2 people |
|
What is the hydraulic system range/capacity |
850-3000psi |
|
What are Ariel cables made of |
Aircraft type plow steel |
|
What is the safety ratio for cables |
4:1 safety ratio |
|
What do velocity fuses do |
Keeps areal in position if hydraulic system fails |
|
How can you tell if a velocity fuse malfunctions |
Ariel will be crooked or operate slowly |
|
What type of cylinders are on Ariel's |
20 year k-bottles: tested annually |
|
T/f You always want to cantilever areil? |
True |
|
What is the most critical aspect of preparing in aerial |
Stabilizing |
|
Pads increase the weight distribution buy a factor of what |
4 |
|
Most a prices are capable of caring a full load up to what percent grade |
6% |
|
Most manufacturers allow operations in winds up ____mph |
35-40mph |
|
Side to side slope of___reduces load capacity by ___ |
3.5-5.5° , 50% |
|
Front to back slope of ___reduces load capacity by___ |
5.5-6.5° , 50% |
|
Wait limits in the operators manual are establish for winds up to |
50mph |
|
T/f Always am ladder hi and lower to victim |
True |
|
____Loads are the worst forces exerting on aerials |
Torsional loads |
|
What do we lubricate the bottom and sides of the glides on the Ariel flies |
Food grade grease |
|
What type of Greece do we use for Zerk fittings |
Extreme pressure 2(EP-2) |
|
What do we lubricate cables with |
Silicone spray |
|
How long is a warranty for Ariel ladders |
20 yrs |
|
Quint 17 shop # |
8756 |
|
When do we lubricate the Ariel's |
End of the month |