1 Handrail
Stairways 1.10 meters or less in width and stairways serving one individual dwelling unit in Group A or 8 Occupancies may have one handrails, except that such stairway, open on one or both, sides shall have handrails provided on the open side or sides: or stairways having less than four risers need. not havehandrails.
1 Handrail
1 handrail for every 3000 mm width of a stairway
1 in 20
Min number of accessible water closet on each floor level where the total of number of water closets per sex is 20
1/10 slope
Max slope of entrance and exit ramps
1/5 one fifth
If only two exits are required they shall be placed a distance apart to not less than
1:100 or 1%
Max Corss Gradient of walkways
1:100 ratio
Ratio of signages meaning 50 cm for 50 m
1:12 ratio
Max gradient for ramps
1:20 or .5%
Max Gradient of walkways
100 mm
Min required curb height at a ramp
100 x 100 mm
(A) Access Symbol , for comfort room stall doors
1000 mm
Min Height of a rail near excavation area for accessibility
1000 mm
Min. Railing Height
1060 mm
Preferred distance above the floor (centerlined) for vertical pull handles, horizontal pull bars for swinging doors with locking devices
1100 m x 1400 m
Min dimension of an accessible elvator
1100 mm
Max height of receivers, signs, dial pads etc above the floor of a telephone booth
1100 mm
Min width of a stairway serving an occupant load of more than 50
1200 mm
Min width of Walkways
1200 mm
Min clear width of ramps
1200 mm
Min clear width of a corridor
1200 mm
Max door leaf width
1200 to 1300 mm
Position of switches above the floor
12000 mm
Max disctance between recess or turnabouts
13 mm x 13 mm
Max dimension of gratings along walkways
1400 / 1600 mm
Min and Max height location on walls and doors
150 x 150 mm
(A,B,C,D) w/ or w/o directional arrows to identify doors, rooms
1500 mm
Min required landings for ramps whose gradient is 1:12
1500 mm / 12000 mm
Min dimension of space and max distance of stops for a whelchair to turn around.
1500 mm x 1500 mm
Min space for recess or turnabout for wheelchairs
1500 mm x 1500 mm
Min clear level space before and extending beyond a door. Except where a door shall open onto but not into a corridor, the required clear level space
1700 x 1800 mm
Min area of an accessible water stall
1800 mm
Min required level area at the top and bottom of any ramp
1800 mm
Any ramp with a rise of 200 mm and leads down towards an area where vehicular traffic is possible, should have a railing across the full width of its lower end, not less than 1800 mm from the foot of the ramp
2 Exits
Min Exits if occupant load >10
2 in 20
Min number of accessible water closet on each floor level where the total of number of water closets per sex exceeds 20
2.25 sqm / 1500 mm
Min space and dimension for wheelchairs outside water stalls
200 mm
Max distance of switches (centerlined) from latch side of the door
200 mm
Min rise of stairs
200 mm
Min run of stairs
2000 mm
Min headroom provided shoud the sign protrude a walkway
2000 mm
Min headroom for walkways (Preferrably higher)
220 x 220 mm
(A,B,C,) w/ or w/o arrows
25 mm
Max height of thresholds and preferrably ramped
30 - 50 mm
Dimenstion of handrails that requires full grip
30 m
Max distance of an accessible elevator from the entrance
300 mm
Extensions of the handrail for start and end of ramps and stairs
300 mm / 400 mm
Max distance of water closets from the wall measured from the toilet seat or 400 mm (centerlined)
300 mm / circle
Washroom sign for female and diameter
300 mm / Triangle
Washroom sign for male and dimension of each side
300 to 400 mm
Height of kick plates that must be provided along major circulation routes made of durable materials
300 x 300 mm
(A,B,C,D,E) For Exterior Use
350 mm
Max tapping rail for the disabled near excavation area
3500 mm
Distance of a turnabout at or within 3.50 m of deadends
3700 mm
Min width of an accessible parking slot
40 mm
Min Handrail Clearance on ledges
450 mm
Max height of water closets (toilet seat)
45000mm
Max Distance of exit/passageway or enclosed stairway along the line of travel to the exit door w/o a sprinkler system
50 mm
Min Handrail Clearance from the wall
500 mm
Min length of a lavatory from the wall
500 mm to 700 mm
Clear height of the lavatory from the floor
6.5 mm
Max projections of gratings above or below walkways, interruptions by cracks or edges
600 mm
Max dimension of handrail supprot for urinals
600 mm
Max distance of the vertical handrail support on both sides of the urinal from the floor
600 x 600 mm
(A,B,C,D,E) For Exterior Use
6000 mm
Max length of a ramp if the gradient is 1:12
60000mm
Max Distance of exit/passageway or enclosed stairway along the line of travel to the exit door w/ a sprinkler system
7.5 mm
Thickness of washroom signs
700 and 900 mm
Height of handrails on both sides from the ramp level
700-750 mm
Min clear width of private stairways serving an occupant load of less than 10
700mm
Min clear witdh of the exitway
800 mm
Min clear width of all doors measured from the hinge to the door jamb at the stop
800 mm
Max height of handrails for water closets above the floor (centerlined)
800 mm
Max height of the lavatory from the wall to the top surface
850 mm
Max height of water fountain
90 Degrees
Exit Door Opening
900 mm
minimum width of a curb cut out
900 mm
Min width of a stairway servin an occupant load of 60 or less
900 mm
Min Handrail width at the back of the water closet and 900 mm on the adjacent side
900 mm
Min. Width of an Exit Door
900 mm - 1200 mm in between
Distance of control panel of accessible elevator from the floor
900 mm / 700 mm
handrail above steps or ramps. May reach upto 1.00 m to 1.06 m for great heights
900 mm preferred
Door knobs and other hardware should be located bet 820 mm to 1050 mm above the floor
A
Access Symbol
B
Phone
Braille Symbols
Should be included in signs indicating public places and safety routes
C
Elevator
Curb cut-outs
should only be allowed when it will not obstruct a walkway or in any way lessen the width of a walkway
D
Parking Sign
E
Ramp
F
Directional Sign
Gratings
Should never be located along walkways
Handrails
should be installed at both sides of ramps and stairs and at the outer edges of of dropped curbs at crossings
Outswinging doors
Should be privided at storage rooms, closets and accessible restroom stalls
Protection
required for doors that swing into corridors
Raised Symbols
For Signages labelling public rooms and places or numbers with min height of 1 mm
Signs
Blue Background with White symbol
TOL/165
Width of exits
Walkways
Should be kept as level as possible and provided with slip resistant material
Water fountain
At least 1 water fountain shall be provided for every 2000 sqm of floor area and on each floor
Exit door
Exit door shall be openable from the inside without the use of a key or any special knowledge or effort: Except, that this requirement shall not apply to exterior exit doors in a Group E or F Occupancy if there is a conspicuous, readily visible and durable sign on or adjacent to the door, stating that the door is to remain unlocked during business hours. The locking device must be of a type that will readily be distinguishable as locked. Flush bolts or surface bolts are prohibited.
Every landing
Every landing shall have a diemension measured in the direction of travel equal to the width of the stairs
Exits
Exits shall be illuminated at any time the building is occupied with lights having an rttensity o·f not less than 10.7 lux at floor level: Except, that for Group A Occupancies, he exit illumination shall be provided with separate circuits or separated sources of :lOWer (but not necessarily separate from exit signs when these are required for exit sign .ftuminatio