1 Handrail
|
Stairways 1.10 meters or less in width and stairways serving one individual dwelling unit in Group A or 8 Occupancies may have one handrails, except that such stairway, open on one or both, sides shall have handrails provided on the open side or sides: or stairways having less than four risers need. not havehandrails.
|
|
1 Handrail
|
1 handrail for every 3000 mm width of a stairway
|
|
1 in 20
|
Min number of accessible water closet on each floor level where the total of number of water closets per sex is 20
|
|
1/10 slope
|
Max slope of entrance and exit ramps
|
|
1/5 one fifth
|
If only two exits are required they shall be placed a distance apart to not less than
|
|
1:100 or 1%
|
Max Corss Gradient of walkways
|
|
1:100 ratio
|
Ratio of signages meaning 50 cm for 50 m
|
|
1:12 ratio
|
Max gradient for ramps
|
|
1:20 or .5%
|
Max Gradient of walkways
|
|
100 mm
|
Min required curb height at a ramp
|
|
100 x 100 mm
|
(A) Access Symbol , for comfort room stall doors
|
|
1000 mm
|
Min Height of a rail near excavation area for accessibility
|
|
1000 mm
|
Min. Railing Height
|
|
1060 mm
|
Preferred distance above the floor (centerlined) for vertical pull handles, horizontal pull bars for swinging doors with locking devices
|
|
1100 m x 1400 m
|
Min dimension of an accessible elvator
|
|
1100 mm
|
Max height of receivers, signs, dial pads etc above the floor of a telephone booth
|
|
1100 mm
|
Min width of a stairway serving an occupant load of more than 50
|
|
1200 mm
|
Min width of Walkways
|
|
1200 mm
|
Min clear width of ramps
|
|
1200 mm
|
Min clear width of a corridor
|
|
1200 mm
|
Max door leaf width
|
|
1200 to 1300 mm
|
Position of switches above the floor
|
|
12000 mm
|
Max disctance between recess or turnabouts
|
|
13 mm x 13 mm
|
Max dimension of gratings along walkways
|
|
1400 / 1600 mm
|
Min and Max height location on walls and doors
|
|
150 x 150 mm
|
(A,B,C,D) w/ or w/o directional arrows to identify doors, rooms
|
|
1500 mm
|
Min required landings for ramps whose gradient is 1:12
|
|
1500 mm / 12000 mm
|
Min dimension of space and max distance of stops for a whelchair to turn around.
|
|
1500 mm x 1500 mm
|
Min space for recess or turnabout for wheelchairs
|
|
1500 mm x 1500 mm
|
Min clear level space before and extending beyond a door. Except where a door shall open onto but not into a corridor, the required clear level space
|
|
1700 x 1800 mm
|
Min area of an accessible water stall
|
|
1800 mm
|
Min required level area at the top and bottom of any ramp
|
|
1800 mm
|
Any ramp with a rise of 200 mm and leads down towards an area where vehicular traffic is possible, should have a railing across the full width of its lower end, not less than 1800 mm from the foot of the ramp
|
|
2 Exits
|
Min Exits if occupant load >10
|
|
2 in 20
|
Min number of accessible water closet on each floor level where the total of number of water closets per sex exceeds 20
|
|
2.25 sqm / 1500 mm
|
Min space and dimension for wheelchairs outside water stalls
|
|
200 mm
|
Max distance of switches (centerlined) from latch side of the door
|
|
200 mm
|
Min rise of stairs
|
|
200 mm
|
Min run of stairs
|
|
2000 mm
|
Min headroom provided shoud the sign protrude a walkway
|
|
2000 mm
|
Min headroom for walkways (Preferrably higher)
|
|
220 x 220 mm
|
(A,B,C,) w/ or w/o arrows
|
|
25 mm
|
Max height of thresholds and preferrably ramped
|
|
30 - 50 mm
|
Dimenstion of handrails that requires full grip
|
|
30 m
|
Max distance of an accessible elevator from the entrance
|
|
300 mm
|
Extensions of the handrail for start and end of ramps and stairs
|
|
300 mm / 400 mm
|
Max distance of water closets from the wall measured from the toilet seat or 400 mm (centerlined)
|
|
300 mm / circle
|
Washroom sign for female and diameter
|
|
300 mm / Triangle
|
Washroom sign for male and dimension of each side
|
|
300 to 400 mm
|
Height of kick plates that must be provided along major circulation routes made of durable materials
|
|
300 x 300 mm
|
(A,B,C,D,E) For Exterior Use
|
|
350 mm
|
Max tapping rail for the disabled near excavation area
|
|
3500 mm
|
Distance of a turnabout at or within 3.50 m of deadends
|
|
3700 mm
|
Min width of an accessible parking slot
|
|
40 mm
|
Min Handrail Clearance on ledges
|
|
450 mm
|
Max height of water closets (toilet seat)
|
|
45000mm
|
Max Distance of exit/passageway or enclosed stairway along the line of travel to the exit door w/o a sprinkler system
|
|
50 mm
|
Min Handrail Clearance from the wall
|
|
500 mm
|
Min length of a lavatory from the wall
|
|
500 mm to 700 mm
|
Clear height of the lavatory from the floor
|
|
6.5 mm
|
Max projections of gratings above or below walkways, interruptions by cracks or edges
|
|
600 mm
|
Max dimension of handrail supprot for urinals
|
|
600 mm
|
Max distance of the vertical handrail support on both sides of the urinal from the floor
|
|
600 x 600 mm
|
(A,B,C,D,E) For Exterior Use
|
|
6000 mm
|
Max length of a ramp if the gradient is 1:12
|
|
60000mm
|
Max Distance of exit/passageway or enclosed stairway along the line of travel to the exit door w/ a sprinkler system
|
|
7.5 mm
|
Thickness of washroom signs
|
|
700 and 900 mm
|
Height of handrails on both sides from the ramp level
|
|
700-750 mm
|
Min clear width of private stairways serving an occupant load of less than 10
|
|
700mm
|
Min clear witdh of the exitway
|
|
800 mm
|
Min clear width of all doors measured from the hinge to the door jamb at the stop
|
|
800 mm
|
Max height of handrails for water closets above the floor (centerlined)
|
|
800 mm
|
Max height of the lavatory from the wall to the top surface
|
|
850 mm
|
Max height of water fountain
|
|
90 Degrees
|
Exit Door Opening
|
|
900 mm
|
minimum width of a curb cut out
|
|
900 mm
|
Min width of a stairway servin an occupant load of 60 or less
|
|
900 mm
|
Min Handrail width at the back of the water closet and 900 mm on the adjacent side
|
|
900 mm
|
Min. Width of an Exit Door
|
|
900 mm - 1200 mm in between
|
Distance of control panel of accessible elevator from the floor
|
|
900 mm / 700 mm
|
handrail above steps or ramps. May reach upto 1.00 m to 1.06 m for great heights
|
|
900 mm preferred
|
Door knobs and other hardware should be located bet 820 mm to 1050 mm above the floor
|
|
A
|
Access Symbol
|
|
B
|
Phone
|
|
Braille Symbols
|
Should be included in signs indicating public places and safety routes
|
|
C
|
Elevator
|
|
Curb cut-outs
|
should only be allowed when it will not obstruct a walkway or in any way lessen the width of a walkway
|
|
D
|
Parking Sign
|
|
E
|
Ramp
|
|
F
|
Directional Sign
|
|
Gratings
|
Should never be located along walkways
|
|
Handrails
|
should be installed at both sides of ramps and stairs and at the outer edges of of dropped curbs at crossings
|
|
Outswinging doors
|
Should be privided at storage rooms, closets and accessible restroom stalls
|
|
Protection
|
required for doors that swing into corridors
|
|
Raised Symbols
|
For Signages labelling public rooms and places or numbers with min height of 1 mm
|
|
Signs
|
Blue Background with White symbol
|
|
TOL/165
|
Width of exits
|
|
Walkways
|
Should be kept as level as possible and provided with slip resistant material
|
|
Water fountain
|
At least 1 water fountain shall be provided for every 2000 sqm of floor area and on each floor
|
|
Exit door
|
Exit door shall be openable from the inside without the use of a key or any special knowledge or effort: Except, that this requirement shall not apply to exterior exit doors in a Group E or F Occupancy if there is a conspicuous, readily visible and durable sign on or adjacent to the door, stating that the door is to remain unlocked during business hours. The locking device must be of a type that will readily be distinguishable as locked. Flush bolts or surface bolts are prohibited.
|
|
Every landing
|
Every landing shall have a diemension measured in the direction of travel equal to the width of the stairs
|
|
Exits
|
Exits shall be illuminated at any time the building is occupied with lights having an rttensity o·f not less than 10.7 lux at floor level: Except, that for Group A Occupancies, he exit illumination shall be provided with separate circuits or separated sources of :lOWer (but not necessarily separate from exit signs when these are required for exit sign .ftuminatio
|