  • Back

Mod 3 sheave damper operating pressure.

750 psi

Mod 4 sheave damper operating pressure.

400 psi

Service stroke of the sheave damper.

8-10 ft

S/D Flapper valve flow.


- On arrestment


- On retraction

- unrestricted on arrestment


- restricted on retraction

S/D accumulator fluid level.

1- 3 inches

S/D Accumulator pressure increases to ( ) psi on arrestment

1500 psi

S/D dyno test.

No more than 2700 lbs

Sheave inspected

- Semi annual or ever 2500 traps


- throat wear: 1.469"


- lip wear: 1/8" no less


- max phenolic wear: 4.028"


- spacer thickness: .266" or less replace.



Purchase cable & CDP diameter

1 7/16 "

CDP length

110 ft

CDP breaking strength

205,000

Purchase cable breaking strength

215,000

Purchase cable inspection

Every 300 traps / monthly. Up to 900 then every 100 traps

CDP height

2 - 5 1/2"

Number of clamps for stretch tests

14

Stretch test psi

200 psi increments up to 1000 psi and hold open for 5 mins.

After 2nd barricade arrestment what is sent to lakehurst?

50 ft of cable from port and stbd sides

Barricade CDP length?

88 ft

Barricade extension pendant length?

10 ft

Wire support cam index wear.

.015"

Wire support forward stop gap minimum?

1/8 "

Engine fluid cooler operating temp?

80 - 130 °f

Engine Fluid cooler max temp?

170 °f

Replace zinc anodes when?

1/2 gone

Number of zinc anodes in engine fluid cooler?

6

Engine fluid capacity without cooler?

380 gal

Engine fluid capacity with cooler?

580 gals

Engine accumulator pressure increases to ( ) psi on arrestment

650 psi

What type of water and how much can be added to the AG engine?

Distilled water (50Gal)


(30Gal for barricade engine)

Replenishment tank capacity

6 Gal

Engine revved ratio?

18:1

Anchor Damper service stroke ?

15 ft 8 in

Engine accumulator max bore

20.250

Engine normal run out

183"

Power pack capacity

125 Gal

Power pack pressures


- operating pressure


- kicks on at


- cracks open


- fully opens


- 1500


- 1250


- 1600


- 1750

Number of deck ramps

12

Mod 4 deck ramps

10

Number of impact pads in picture frame

13

Popping barricade height off deck

6 - 12"

E2C2 midspan height

21 ft

E2C2 center clearance

40 ft

Ready jet midspan height

20 ft

ARC weight setting X =

10,000 lbs

Psi difference between gauge and GUI

No more than 150 psi

(Primary/alt bus)


ARC engines match weight setting within

+- 200 lbs

(Manual mode)


ARC engines match weight setting within

+- 500 lbs

Auto Lube pressure

80+-5 psi

Auto lube shots (normal)

6 shots / 30 seconds

Auto lube shots (newly reeved first 50 traps)

24 shots / 30 seconds (old as fk)

Aux air pressure

2500 - 3000 psi

HPU fluid capacity

5 Gal

Primary and failsafe accumulator pressure

2525 - 2950 psi

HPU hose service life.

6 years

RCV spring

103 lbs ( I have 50 lbs)

RCV motor

90 hp

Two types of transducers

5k & 15k

UPS power time

2 hours / 30 traps

UPS batteries

Twenty - 12v batteries

Max allowable float

0 - 1/32"

No wire within ( ) of terminal wall

3/8"

Max recessions


- new


- R5

- .060


- .125

Socket pouring drill

450 - 700 rpm

Replace bent tube after

11 wires

Degreaser ratio/time/temp

4:1


Water:degreaser



45 - 60 min



90 - 100°f, 110°f max

Flux temp

160 - 210°f

Socket pouring water temp

160 - 200°f

Flux expires

20 years from manufacturing date

White temp stick

550 °f

Red temp stick

600 °f

Zinc temperature

925 - 975°f



Discard after 1075°f

Pull test new sockets at

120,000 lbs for 2 mins

Wire recessions

Max of six


No deeper that 1/32"

Mod 4 retractable sheaves

Height 7 inches


160+/-5 psi

Barricade stantion height

24 ft

Counter balance springs adjusted in the

Raised position

Engine vertical slippers prevent

Fish tailing of X-head

What secures the MEC to the 5in sleeve?

4 segmented clamps

Number of slippers on ram slipper cage

12

What secures the Ram to the X-head?

Split retainer

Ram packing float set to ( ) to prevent leaking due to vibration

0 - .010

Sheaves in a nest

18

Sheaves in a bank

9

Number of slippers on X-head

16

Number of spacers per bank

10


8 bonded


2 loose

Max high speed spacer wear

.050"

Sheave throat depth

Max: 3/16"


New: 1 1/4

Flex hose reel tension

9 +/- 1/2 ft lbs

Master distribution block relives at

2200

Primary distribution block relives at

1800

Accumulator safety disk ruptures at

1500 psi

Accumulator hydrostatic test to

2000 psi for 30 mins

Accumulator floating piston slipper cage has ( ) slippers

24


12 on both sides

Accumulator air tightness test

Charge to 1000 psi


Let sit for 24 hrs


Max 20 psi drop for temp changes

Aux air flask hydrostatic test

5000 psi

Number of copper tubes in cooler

107


Max of 20 pluged

Scavenger tank capacity

90 Gal

Stowage tank capacity

700

Max high speed spacer wear.

.050

What holds the retract valve closed

Spring tension and accumulator pressure

S/ D flow control valve orfice

1/2

Counter balance cable diameter

7/8

Tensioning pendant cable diameter

5/8

wet webbing

10 - 15 % reduced strength


40 - 45 % increase weight

Dragging a barricade webbing.

Reduces strength by 30 - 35%

Barricade webbing shelf life

1- 8 = 7 out of box


9 = 6


10 = 5


11 = 4


12 - 15 = 3

O ring shelf life

5 year / 20 qtrs

V ring shelf life

3 years / 12 qtrs