Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
32 Cards in this Set
- Front
- Back
What is the Blue system pressure when supplied by the RAT? |
2500 PSI |
|
How many pumps comprise the hydraulic system? |
2 engine driven pumps 2 AC pumps 1 hand pump 1 RAT |
|
When is the Power Transfer Unit (PTU) inhibited ? |
During the first engine start 40 seconds after the end of cargo door operation |
|
When does the PTU activate? |
Switch in auto and greater than 500 PSI difference between the yellow and green systems |
|
What is the purpose of the 3 priority valves? |
Cut off heavy load users from the system when pressure in the system is low and the demand is high |
|
Where are the hydraulic filters located? |
Each system Reservoir filling system Return lines Engine pumps Blue system electric pump Normal braking system |
|
What pressurizes the hydraulic reservoirs? |
High pressure bleed air from engine 1. If the pressure drops below a given level, air is taken from the crossbreed duct. |
|
Why is it necessary to maintain high pressure in the hydraulic reservoirs? |
To prevent the pumps from cavitating. |
|
What system powers the normal brakes? |
Green |
|
What system powers the Alternate brakes and parking brake? |
Yellow |
|
What system powers the landing gear and NWS? |
Green |
|
FAULT light on ENG PUMP push button and ECAM? |
Reservoir level low Reservoir overheat Reservoir air pressure low Pump delivery pressure low (inhibited on ground with engine off) |
|
If the crew selects the ENG PUMP switch to off after a fault, when does the FAULT light continue to be illuminated? |
Overheat while temperature is still too high |
|
When does the Blue electric hydraulic pump operate? |
Push button in auto: In flight On ground with one engine running or if the crew pressed the BLUE PUMP OVRD pushbutton |
|
FAULT light on BLUE ELEC PUMP pushbutton and ECAM? |
Reservoir level low Reservoir overheat Reservoir air pressure low Pump delivery pressure low (inhibited engines off on ground) Pump overheats |
|
If the crew selects the BLUE ELEC PUMP off after a fault, when does the fault light remain illuminated? |
An overheat, as long the temperature is still too high |
|
What happens to the YELLOW ELEC PUMP if the electrical power supply is removed? |
The pump turns off and remains off even if electrical power is Re established |
|
When the YELLOW ELEC PUMP pushbutton is off, when will the yellow electric pump come on automatically? |
When the cargo door manual selector valve is selected to OPEN or CLOSE. (Inhibits other yellow system components except alternate braking and eng 2 reverser) |
|
FAULT light on YELLOW ELEC PUMP pushbutton and ECAM? |
Same as Blue system, except no engine inhibit. Reservoir level low Reservoir overheat Reservoir air pressure low Pump delivery pressure low Pump overheat
|
|
What is the normal function of the PTU when the engines are shut down on the ground? |
Allows the green system to be pressurized by the yellow system |
|
When is the PTU automatically tested? |
During the second engine start |
|
What does a fault light on the PTU pushbutton and associated ECAM mean? |
Green or Yellow reservoir low fluid level Green or Yellow reservoir overheat Green or Yellow reservoir low air pressure |
|
What it the purpose of the hydraulic filters on the engine pumps and blue electric pump? |
Permit maintenance to monitor engine wear by checking for metallic particles |
|
Describe the BLUE PUMP OVRD switch on the Maintenance Panel |
ON- the blue electric pump is on if the ELEC PUMP pushbutton on the HYD panel is in auto |
|
Describe the FIRE VALVE indications on the ECAM HYD page |
Cross line amber: valve fully closed In line green: valve not fully closed |
|
What do the different RAT colors mean on the ECAM HYD page? |
White: RAT stowed Green: RAT not stowed Amber: Pressure for stowing the RAT has been applied, or the RAT pump is not available |
|
When does ELEC on the ECAM HYD page turn from white to amber? |
If the associated power supply fails |
|
Describe the Yellow system ELEC PUMP control indication on the ECAM HYD page. |
White: electric pump is off Green: electric pump is on Amber: electric pump is on and yellow system has low pressure |
|
What is indicated by cross line amber for the ENG PUMP control on the ECAM HYD page? |
Pushbutton is off |
|
When do the System label and System pressure indication become amber on the ECAM HYD page? |
System pressure below 1450 psi |
|
What hydraulic memo messages can you see? |
RAT OUT: (green) RAT not fully stowed. (Amber) during flight phases 1 and 2 HYD PTU: (green) when PTU is running |
|
When do the engine numbers on the ECAM HYD page turn amber? |
Respective engine N2 is below idle |