What year are patrols?
Patrol 7 (6177) and 8 (6176) were manufactured in 2001. Patrol 6 (6178) was manufactured in 2008.
What are fuel capacities of Patrols?
All three Patrols are unleaded gasoline with 30 gallon capacity
GVWR of patrols?
15,000 lbs. Weight fully loaded is 13,980 lbs with no personnel or P.P.E.
Patrol pumps rated output in terms of GPM and psi?
Pumps are single stage centrifugal Cascade fire pumps rated at:
90 GPM @ 100 psi / 70 GPM @ 200 psi / 23 GPM @ 300 psi
think, 90 70 and Michael jordan
Patrol pumps description and capacity in terms of HP?
The Pump Engine is a Briggs & Stratton “Vanguard” single cylinder, 4-stroke motor, rated at 18 HP @ 3600 RPM. Gasoline is supplied from the vehicle’s fuel tank.
think vanguard - or V twin 18
Type and capacity of winch of Patrol?
A Warn winch is mounted to front bumper with a 15,000lbs rated capacity. Winch accessories are stored in rear passenger compartment. 15’ Control cable with Toggle switch stored in the glove box. 90ft of 7/16 “ cable
Water capacity of Patrol?
300 Gals
Primer type and capacity of patrol?
Flojet 12v, 5.0 gpm @ 25 psi
think PP - FJ like a toyota fj with bodno (primer) 5/25
Hose on Patrols?
Hose: 400’ of 1” accordion loaded. Two 25’ pre-connected 1” lines on either side of the Patrol. One 25’ preconnected 1’ line on the passenger side of the front bumper. One 25’ preconnected 1 1/2’ line on the driver side of the front bumper. Two 1 ½” forestry packs or rolls, with 200 feet in each
Type of saw on patrol?
One Stihl chain saw, with gas and chain bar oil, chain saw PPE
Type of floto pumps on Patrol?
Floating Pump: Waterous or Fyr-flote, (see Block III, Unit A, Task 7 write-ups for more information)
Types of tools on Patrols?
Assorted Tools including: Brush hook, Pulaski, Shovel, McCleod, spanners, flares, hard suction, strainer et
Type and amount of foam on Patrol?
Twenty gallons of Class A foam. Depending on the foam unit; 20 gallons in a single tank or 15 in storage tank and 5 in bladder
Lighting on Patrol?
(2) 500 watt Telescoping lights
Type of Proportioning unit of Patrol 6?
Patrol 6 (6178) has a Foam Pro Hypro proportioning unit
p6 has FP Hp P - Think more HP
Type of Proportioning unit on Patrol 7 and 8?
Patrol 7 (6177) and 8 (6176) have a Robwen Hydro-Flo proportioning unit
7 and 8 has two words in prop unit name
Describe suspension modifications on Patrol 8?
Patrol 8 (6176)has been outfitted with a 3 ½” suspension lift and a Detroit Tru-Trac rear differential locker for better off-road capabilities
Describe Patrol generators for each rig?
Patrols 7 (6177) and 8 (6176) have an AuraGen G5000 generator. Patrol 6 (6178) has a Redi-Line Inverter.
7 & 8 think acura - not g6 but...
6 is a Redy for anything
Patrol generators / inverters description?
• Built rugged and reliable with sturdy steel housing.
• Patented Demand Start Circuitry extends battery life.
• Easily delivers peak output currents up to 1.5 times the continuous output.
• True sine-wave output.
• GFI outlet.
• Operates in ambient temperatures from -30°F to 130°F.
120 / 240 v
Describe foam unit of Patrol 6?
Foam Pro Hypro
Foam Output: 1.0 gpm @ 200 psi
Pump Motor 1/3 hp
Max Operating Temp:160 F
Max Operating Pressure: 400 psi
Max System Capacity: 100 gpm at 1.0% foam concentrate
Describe Foam unit on Patrol 7 & 8?
Foam system:Robwen Hydro
Foam Output: 5 – 50 gpm (varies due to pump capacity /output)
Pump Motor: No motor. This system utilizes bladder system.
Max Operating Temp: N/A
Operating Pressure:40 – 450 psi
Max System Capacity: Variable due to gpm flow.
Rob(tanka)wen run 7 or 8 times and for went 5/50 catches