• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/46

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

46 Cards in this Set

  • Front
  • Back
temperature, humidity, airflow, air quality, radiant effects all are factors that effect...
comfort
there is no evaporation if the air is...
saturated
a wet bulb thermometer will measure the same as a dry bulb thermometer if...
the air is saturated
a measure of sensible heat
temperature
a measure of latent heat
water vapor
air conditioners remove...
sensible and latent heat
latent heat includes...
humidity
heat gains through...
walls, roof, windows
how does glazing on windows effect heat
increases
thermal resistance (R values) are...
cumulative numberst
are U-factors cumulative
no
shading coefficient for clear class is..
1.0
can you over-insulate
yes
over insulation results in not being
energy efficient
for energy efficiency what should you do with glass
keep it to a minimum
for energy efficiency, you should avoid ____ & ____ orientation
east & west
___________ are used to produce signals for adjusting systems to maintain desired conditions
controllers
most controls in institutional buildings are...
DDC (direct digital controls)
_______: valves and dampers are used to adjust flow in response to controller signals
actuators
__________ send signal to an ________
controllers, actuators
these are basically small air handling units located in or above conditioned spaces
fan coils
chilled water or hot water circulated through piping, encased in floor or at ceiling
radiant heating or cooling
provides heating and cooling and needs separate air system for ventilation
radiant heating or cooling
window or through wall units complete with compressor and optional electric heat. needs outside wall
package terminal air conditioners
the lower comfort level in cold weather is at __ F and __% RH
68 degrees
30% relative humidity
the upper comfort level in hot weather is at __F and __% RH
79 degrees
55% RH
an interior design temperature of about __ F is considered comfortable
75 degrees
what deals with properties of air + water vapor mixtures
psychrometry
Temperature At Which Moisture Will Condense From A Given Air Sample
dew point
enthalpy is also known as
total heat
Similar To Fancoils, Except Units Are Reverse Cycle Heatpumps
water source heat pumps
Use Refrigeration Process To Extract Or Reject Heat For Cooling Or Heating
water source heat pumps
high humidity is >__%
greater than 60%
uncomfortable drying (humidity) is less than __-__%
less than 25-30%
an area for which temperature is controlled by a single thermostat.
HVAC zone
areas of humidity control can be termed a
HVAC zone
these two things reverse the refrigeration to heat as well as cool
water source heat pumps
package terminal units
these are limited to rooms with outside exposure
PTACs (package terminal air conditioners)
these do not need access to the outside air for condensing
water source heat pumps
can air conditioners be used as heaters in warmer climates (down south) by reversing the process
yes
DX
direct expansion
this removes heat by compressing air and atoms
air conditioner
this type of system is when a refridgerant is used in the coil
DX
this type of system is when the compressor is included with the equipment
unitary system
limitation of a DX system
the system must be in close proximity with the outdoors.
what is a more economical choice for pipes in summer (gas or electric)