Name 4 symptoms associated with exposure to fire extinguishing agents.

light headedness




headaches




shortness of breathe




nausea

How does not having enough nitrogen charge affect an agents discharge?

the cylinder won't have enough pressure to properly discharge

What results when the extinguisher is discharged if a frangible disc strainer were not installed in the liquid-agent fire extinguisher container?

Pieces of the disc could clog the tubing and nozzles.

What happens if the time delay relay in the 2 shot fire extinguishing system does not operate properly?

The extinguisher may fire into the wrong engine

What happens after the pilot places the No. 1 engine selector switch to the ON position?

Positions wing selector valve and No. 1 engine selector valve so that the agent can reach the No. 1 engine

What happens once the fire emergency control handle (T-handle) is pulled?

Current flows to the squib. The squib breaks a post and agent discharges

What must you do before depressing the discharge switch of the T-handle system during an operational check?

Ensure the electrical connector is disconnected from the squib to prevent accidental discharge

List the characteristics of liquid coolant.

dielectric




nonconductor




noncorrosive

During a liquid coolant system's operation, the liquid coolant is at normal temperatures. How is the temperature kept from changing?

heat exchanger

What is the maximum amount of time you can safely fun the liquid coolant system in the test position?

6.5 minutes

What visual indicator alerts you to a dirty liquid coolant filter?

Pop up differential indicator

What happens when the temperature of the coolant exceeds 115 degrees F during system operation?

Pilot valve closes.




Modulating valve closes.




Coolant goes through heat exchanger

What is the procedure to replace the liquid coolant system filter?

have new system on hand.




clean filter bowl with cloth




reset pop up indicator

What should you do if the ASP indicates FAILED condition or you suspect contamination of a liquid coolant system?

Purge before operation

Why must the servicing unit supply hose be purged before you put coolant into the liquid coolant system?

To flush the hose of contaminants

How is the cable and ball assembly used to release the CO2 from the one-person life rafts inflation assembly?

The ball of the assembly is engaged into a slot in the rotating cam. When the cable is pulled, the cam releases CO2

How is the one-person life raft's inflation assembly protected from excessive pressures?

CO2 breaks rupture disc and releases pressure

Why is it important to use the size and type of wire specified by the TO when safety sealing life raft inflation cylinder?

If wrong size/type is used it may make discharging the cylinder impossible

What must CO2 go through before it is allowed to recharge a cylinder?

Must pass through 2 dehydrator filters connected in series

You're ready to recharge an empty inflation cylinder. You find the weight of the empty cylinder doesn't match the weight stenciled on its side. What do you do?

Restencile before servicing

What must you do when you're recharging a one-person inflation cylinder after stenciling the cylinder?

Use scribe to raise and release locking sleeve

You have attached the charging hose to a one-person life raft cylinder, laid the assembly on the scale and opened the check valve. What happens next?

Charging pressure opens check valve

What safety step must you take before bleeding pressure from the one-person raft inflation assembly?

Install diffuser plug in charge and discharge port

A one-person life raft inflation assembly has just been recharged. What must be done before it can be installed on a life raft?

Must be submerged in water for 30 minutes and then reweighed 24 hours later

Why must aviators breathing oxygen be nearly "bone dry"?

Moisture can cause the system to work ineffectively

What effects does a lack of oxygen have on the body?

blurred vision




shortness of breathe




weak feeling




dizziness

What can cause gaseous oxygen to leak at the filler valve during servicing? How can this problem be corrected?

Unpropper connection




replace filler valve

What construction method prevents high-pressure gaseous oxygen cylinders from shattering?

By using heat treated alloy or by welding metal bands to outside surface

How do high-pressure oxygen lines differ from low-pressure oxygen lines?

High pressure- copper alloy; silver solder fittings




Low pressure- aluminum alloy; flared fittings

What happens if the MSOGS concentrator fails?

It will turn on an oxygen caution light in the cockpit and automatically switch to the BOS

Whats the purpose of the pressure-opening valve?

opens if head pressure in the container builds up approximately 10 psi above normal

How does warm-up coil convert liquid oxygen to gaseous oxygen?

its large surface area lets liquid oxygen absorb heat and evaporate to a gaseous state before reaching the regulator

With what types of oxygen systems can the MD-1 oxygen regulator be used?

Gaseous or Liquid at high or low pressure

How is oxygen increased to the user at an altitude of 30,000 ft by the pressure-demand regulator?

The diluter aneroid closes the air inlet valve and the user will get 100% oxygen

Whats the purpose of the troop oxygen system?

Used on larger aircrafts that are capable of carrying troops, paitients

Whats the intended use of the bailout bottle?

Emergency oxygen assemblies that are intended for high altitude emergencies or parachute decent

How does the capacitance indicating system change its indication as the quantity changes?

The capacitance of the probe decreases if the quantity of the LOX in the converter decreases

Why is coaxial cable used between the quantity indicator and converter probe?

The container indication signal moving in the signal wire is protected from stray external signals by the cable

What should you do if you find chaffed mask-to-regulator hoses?

Replace hose

During an inspection, the no-go part of a go-no-go gauge passes into the smallest part of the connector, what should you do?

replace connector

What safety precautions must you take when you find oxygen tubing within 2 inches of electrical wiring?

Bend or reroute oxygen tubing to maintain 2 inches of clearance

What are the potential discrepancies you should look for when you're inspecting an oxygen converter?

ensure its mounted securely and are free of damage, excessive dents and loss of vaccum

What should you check for when installing oxygen tubing in an aircraft?

make sure it is free of leaks

What should you do as you are installing an oxygen component near fuel lines?

6 inches of clearance between the two

How should you apply anti-seize tape to a fitting?

sparingly, so it doesn't get into the system

How do you prevent oxygen fittings from turing as the B-nuts are loosened or tightened?

hold fitting with a wrench

What should you do as you re installing a bonding jumper?

make sure its the right length and has low resistance

What should you do if an odor is identified in a gaseous oxygen system?

Purge it

What must you do first before connecting the service valve to the aircraft?

Bleed recharging hose

What is the procedure for purging a converter assembly?

1) Drain


2) Connect to purge kit


3) Adjust to 115 VAC 60-400 cycles


4) Pressurize equipment


5) Leak check


6) Circulate air and turn on Heat element

What are the steps to hot purge an aircraft LOX system?

1) connect purge kit


2) buildup position


3) turn on regulators


4) cool down


5) service with lox

Before leak testing a gaseous oxygen system, and after filling the system it is imperative to perform this action.

Recored gauge pressure and ambient temperature

You insert a check valve leak tester into a filler valve and wipe film of soap solution over open end of the tester. Very quickly the soap bubbles out, what is the next step?

Determine what valves are leaking

What type of insulation is used in the annular space of the TMU-27/M servicing unit?

aluminized polyester film insulation

Why are thin, stainless steel supports used between the inner and outer tanks of a cryotainer?

so they don't conduct much heat to the inner tank

What malfunction would you suspect if there were an overpressure condition on the outer tank?

leak from the inner tank to the annular space

How does the capacity gauge work on the TMU-27/M liquid storage and transfer cart?

The dial indicator is coupled magnetically and mechanically to a float sensor inside the inner tank and calibrated in gallons

Where should you reference prior to cleaning components?

T.O. 15X-1-1 Oxygen Equipment

What precautions should you take prior to handling internal parts?

Never clean components with previously used cleaning solvent.




Wear disposable gloves

What 6 items should you consider to ensure an adequate level of cleanliness before cleaning oxygen components?

1) cleaning facilities


2) pick a cleaning agent


3) pick a cleaning method


4) inspect for cleanliness


5) drying


6) packaging

What are the steps to removing a solvent cleaner from a component?

1) must be dry




2) Purge with clean air




3) continue drying




4) visually inspect

What is important to do before beginning the draining process?

Ensure the container is free of all hydrocarbons such as oil, grease, gas and wood

What is your next step once the tank is drained?

Purge

If you notice the blower turning the wrong way, what steps must you take to correct it?

Stop the unit and change the setting of the phase reversal switch

You are purging a cryotainer and it reaches a temperature of 200 degrees F. How long are you required to purge?

2 hours

Explain how a rotary vacuum pump operates.

rotation from the pump driven sheave causes the shaft to turn




this turns the blade and draws in air

What steps should you take if an air purging unit isn't available and a cryotainer needs to be evacuated?

Open seal off plug. Run pump until all air is gone from hose. Open vale and operate pump until the vacuum reaches the required valve. 8-24 hours.

While transferring liquid oxygen to an aircraft using TMU-27/M servicing trailer, you notice the rate of servicing is very slow. What are some of the probable causes?

Plugged filter in the service line




Leak in service line or hose




Low tank pressure

You identify the cryotainer is continually venting, and know the buildup valve and vacuum are good. What component spaces should you check?

build up valve internal leakage




loss of vacuum in annular