LIST THE SIX POINTS COVERED IN THE TAILBOARD BRIEFING

Purpose of the job


What he or she is to do


What other crew members are to do


Supervisors manner of doing the job


Hazards/trouble spots


Status of lines and equipment



1. Each employee will understand the purpose and critical steps of the job


2. Each employee will understand what he/she is to do.


3. Each employee will understand what the other employees involved in the work assignment are to do.


4. Each employee will understand the supervisors manner of the feeling the work assignment, including understanding the criteria for backing out of a job one unexpected conditions arise.


5. Each employee wander stand the hazards or trouble spots involved and will take the necessary actions to overcome each problems and if accable what personal protective Equipment will be required.


6. Each employee shall be notified by the supervisor or other employee in charge of the conditions or clearance of lines or quipment before work is started. Where accable the supervisors shall notify each employee of any change to the conditions of status of lines or equipment. When the supervisor is not present at the job site and either expected job Conditions are found to be different from initial tail board or later change, work will be stopped until the supervisor is notified by the involved employees and an agreement of how to handle the new conditions safely will be reached before work proceeds.

What forms of PPE are required when working on A wood Pole

Hard hat, safety glasses, long sleeve shirt rolled down, pants and boots

When is a face shield required

When working on or near expose energize 3 phase systems In pad mounted equipment, pull sections or electrical panels. Approved eye protection, and a hard hat with full are graded face shield would chin guard attach shall be worn.

When must rubber gloves be worn

Approved rubber gloves shall be worn at all times when working on exposed energized conductors ranging from 120 V to 17KV (AC nominal)

Are Pole mounted grounds allowed in climbing space? If so what provisions must be observed?

One ground is allowed in the climbing space but must be sufficiently covered.

Are Pole mounted grounds allowed in the climbing space of rack construction?

No, In rack construction grounds are not permitted in the climbing space Per GO 95

What are the 4 "rules that will keep you Alive"?

1. Must Where required fr clothing when performing any task that involve working on or near energize lines and equipment.


2. Use require fall protection while in aerial lifts or climbing a wood pool.


3. One required, use protective cover and high voltage rubber gloves while working on or near high voltage lines in equipment.


4. Lines in equipment, normally energize above 600 V, must be tested and grounded when required, utilizing persons grounds between the work location and every source of supply, prior to contact.

What is the definition of climbing space on a poll?

The space reserved along the surface of a climbing Pole or structure to permit lineman ready access to equipment and conductors on the Pole or structure.

When is it required to sound test a poll? How is the test performed?

Visual and sound inspection for any evidence of damage or insect infestation. Sound test is From ground level to 6' above grade using the hammer.

What is the minimum length for climbing gaff, when measured from bottom flat surface? Why should these gaffes not be used?

1-1/4" Gaff in not be used because gaff no longer engage proper death for climber.


APM 230

How many employees are permitted to ascend or descend a pull at the same time? Why?

One employee shall ascend or descend A-pole at 1 time. safety concerns.

What is the purpose of G. O. 95

Provides rules for overhead electrical line construction, as prescribed by the PUC of the state of California.

Explain the "zone of proximity" as it relates to guy wire.

Guy wire in the zone a proximity means a guy of which any part is both within a vertical distance or less than 8' from the level of supply conductor and a radial distance of less than 6' from the surface of the Pole or structure.

Name all 8 obstructions you can have in climbing space of of arm construction.

1. Braces and hardware


2. Cross arms


3. Vertical riser


4. Street light bracket


5. Guy wires


6. Ground wire


7. Switching Rod


8. Runs

Before installing a meter panel, it must be "buzzed out" first? Why is this done? How is this accomplished?

Buzzing out the meter panel is checking for continuity.


Checking


ground-to-ground


Each phase to ground


Each phase to phase


Why do we ground?

Protect workers from Hazards. Grounding is required for the protection of the worker when working on DE energized high voltage lines or equipment. Use of personal grounds will minimize exposure associated with making contact with objects having hazardous differences of electrical potentials. Workers should avoid contact with applied grounds whenever possible to minimize exposure to hazardous conditions.

What are the grounding medium Priorities?s

Approve ground mediums in order of priority are:


1. Substation ground


2. Multi grounded primary neutral


3. Steel structures


4. Anchor rods


If none of the foregoing are available, use approved temporary ground rod(s)


What is back feed? How is low voltage back feed addressed?

A source of supply from the load side of the Electrica system to a DE energized section of line, apparatus or equipment.


Before contacting DE energized low voltage conductors or equipment, all possible sources shall be eliminated or sort circuited, or they shall be considered energize and worked on in accordance with the established rules.


Before contacting DE energized low voltage conductors or equipment, all possible sources shall be eliminated or sort circuited, or they shall be considered energize and worked on in accordance with the established rules.


When short circuiting at the customer panel, shunts shall be connected to each phase, the neutral and the customer ground.

#4 ACSR current capacity (amps)


And dead end tension

160 amps


604 lbs

#2 ACSR Current capacity (amps)

210 amps

1/0 ACSR Current capacity (amps)


And dead end tension

280 amps


1,415 lbs

4/0 ACSR Current capacity (amps)

415

336 kcmil ACSR Current capacity (amps) And dead end tension


605 amps


2,846 lbs

653 kcmil ACSR Current capacity (amps) And dead end tension

920 amps


3,267 lbs

#6 Triplex (Al) Current capacity (amps)

80

#4 Triplex (Al) Current capacity (amps)


And dead end tension

110 amps


604 lbs

#2 Triplex (Al) Current capacity (amps)

145

1/0 Triplex (Al) Current capacity (amps)


And dead end tension

190 amps


1,415 lbs

4/0 Triplex (Al) Current capacity (amps)


And dead end tension

300 amps


2,780 lbs

#4 Quad current capacity (Amps)

100

1/0 Quad current capacity (Amps)


And dead end tension

180 amps


1,415 lbs

4/0 Quad current capacity (Amps)


And dead end tension

275 amps


2,780 lbs

What is an overhead equipotential zone, and how is one set up?

An EPZ Is an area that has the same Potential. After the poll band and grounds have been applied and EPZ zone is established. The epz is the area on the Pole above the Pole band Including the conductors or equipment connected to the poll band to be worked on. In addition, though work space extends to the top of the Pole. However the work space does not extend inside the minimum approach distance of energize or DE energize circuits not connected to the poll ban. In cases where the workers have installed to pull bands the EPZ workspace will be the area on the Pole between the 2 pole bands

What are the dimensions of climbing space in multi-plex construction?

30"x 30"

Prior to working in an elevated position, what are employees required to do?

Employees shall familiarize themselves with the circuits, voltages, apparatus thereon and any unusual conditions that might present a hazard.


APM 209

How do you but test a poll?

If the pool is in doubt. Boring shall be drill 90゚ apart with a 9/16 bit. The 1st Boer shall be 12" below grade and the 2nd shall be at ground line. Drill downward at a 45° Angle and extend past the center line of the poll But not near then 2" of the opposite side.


The inspection boring shall be adjacent to the largest check or other area indicating internal decay. When the poll is set in pavement the above test shall be Conducted by drilling the 1st hole at ground level, 12" above Ground level for the 2nd boring and 90° apart.


Boring holes shall be ploude with a 5/8" inch bit.


APM 202

What is the function of a mechanical cross arm gain?

Ensure that the cross arm is mounted to the wood Pole on a solid and level surface.

What are the dimensions of a 4kv working space on a single line arm construction?

30" square


Outside pin to outside pin, and 30" deep. The vertical dimensions of the working space above and below the supply conductors level energized above 7500 V shall be = the entire vertical distance between the supply conductors involved.

What are the dimensions of 12KV working space in double book arm construction?

36" square


Outside pin to outside pin, and 36" deep. The vertical dimensions of working space above and below supply conductor levels energize above 7500 V shall be equal to the entire vertical distance between the supply conductors involved.

What is the minimum distance for a Tri plex spreader from the face of the poll, per sce standards?

15" From the face of the poll

Where are poll steps located on Poles with distribution apparatus energized at 600 V or greater?

The 1st Pole step shall be installed no less than 9' above the ground line and not more than 6' below the lowest energize apparatus at the distribution level.

Explain the APM rule concerning metallic rulers

Metallic ruler shall not be used near exposed energized equipment. Cloth tape with metal reinforcing shall Not be used on the system under any condition.


APM 135

What is the minimum height for a span guy eye at point of attachment above grade?

7'

What is the minimum distance between 2 guys at point of attachment on the same poll?

The attachment of one guy shall not overlap that of another, but each shall be entirely independent of the other and at least 12" apart at the point of attachment to the poll.

How many Johnny balls are required for polls on 33Kv circuits? What is the spacing requirement for them?

2 Johnny ball's in serious are required.


The to Johnny ball shall not exceed 3' in length.

What is the prescribed distance away from the poll, along the guy wire, were Johnny ball's shall be placed? What is the required distance from grade?

6 to 9' down the guy wire, away from the poll. No Johnny ball should be less than 8' from grade.

May an employee work above another employee on the same poll at the same time?

Yes. When it becomes necessary for one employee to work above the other, extreme care shall be exercised.


APM 209

What is the minimum depth of a breast block?

2'

What is the function of a guy strain insulator (Johnny ball)?

Guy strain insulators insulate accessible portions of guy wire from electrical current. They are required to protect human and animal life.

Where is a poles brands located?

25 to 60' Poles, 10' from the butt


65' or greater, 13' from the butt

A new installations, what is the distance a plate anchor rod extends out of the ground?

As close to the ground as possible and the entire eye of the anchor rod is above the surface.

What determines the size and type of anchor used?

Anchors shall have allowable working strength equal to or greater than the working strength of the guy or guys attached to it.

What is the minimum height of a Queen's post?

8'

When should plate anchors be used?

Plate anchors will continued to be used in extremely loose soil, in accessible areas or rock bed areas.

When installing screw anchors, what is the shearing value of one shear pin? What does a shared pin indicate?

500' pounds


A pre determined amount of pin sheared will predict the holding strength of the Anchor.

What is the minimum depth for installation of its screw type guy anchor.

5 times the helix Diameter

What are the acceptable tree species used for poles?

Pacific coast Douglas Fir


Western red Cedar

What is the difference between a buckarm and a crossarm?

Crossarm: Means a horizontal support attached to the Pole or structures generally at right angle to the conductor supported.



Buckarm: Means across I'm used to change the direction of all or a part of the conductors on the line arm immediately above or below. A buckarm is generally place at right angles to the line arm.

When our plastic snapper guy guards installed?

On all new required construction. Except in fire clearing areas.

In making a copper to aluminum connection, which metal should be placed on top and why?

Copper corrodes in the atmosphere, but copper oxide unlike aluminum oxide, dissolves in water this copper solution accelerates the corrosion of aluminum. To prevent it from Flowing over aluminum, the aluminum conductor shall always be placed on top in copper to aluminum connections.

What is a minimum size conductor used for single phase transformer grounds?

#6 copper

What is the criteria for Locating an EXO meter for a dwelling or apartment?

Meter and service equipment shall be installed on exterior wall or exterior meter closet and so located that the meter and service equipment shall be accessible without entering the building. meter location shall be Selected so that 24 hour access is provided.

Who should be notified when entering an attendant substations?

Any personnel entering an unintended Station Control house, shall report their presence and purpose within 2 minutes to the switching center system operator having jurisdiction and the acting operator on site. If applicable.

Above what voltage is a clearance required for work on DE energize lines in equipment.

Clearances are required to work on DE energize lines or line sections above 600 V. When clearances are required they shall be taken in accordance with the 700 section of the APM.

What are the key steps in the grounding process?

1. Conduct a thorough


2. Determine grounding requirements


3. Inspect grounds before use


4. Clean ground connections


5. Test conductors DE energized


6. Apply proper grounds


7. Remove grounds

What is the preferred method of overhead grounding?

Overhead EPZ bracket grounding is the preferred method and may be used in all grounding scenarios whether the Sources are open or isolated.

List 6 different types of overhead insulators

1. Standoff insulator


2. Plant top insulator


3. Pin type insulator


4. Horizontal post insulator


5. Suspension type insulator


6. Guy strain insulator

APM

Accident prevention manual

DDS

Distribution design standards

DOM

Distribution operations and maintenance policies and procedures

DOH

Distribution overhead construction standards

DUG

Distribution underground construction standards

G.O. 95

General order 95

G.O. 128

General order 128

UGS

Underground Structures standards

RSM

Rigging standards manual

RGM

Rubber glove manual

ESR

Electrical service requirements

What is the procedure for installing a porcelain or polymer post type insulator for tie top insulators?

1. Install on to the appropriate stud in line with conductor.


2. Place conductor in saddle and tie securely

What is a mid span? What tools are used to install a mid span?

Made spans our service lines taken from the mid point of A-pole to Pole service instead of directly from a pole. This is done because rules involve whether A-line can cross someone's property or protect property or people.



Proper PPE, hand tools, approved extension ladder, triplex spreading tool, Rubber blanket and 1/2 inch rope and sling

What is a secondary blanket? How do You install a secondary blanket during mid span installation?

A secondary blanket is used to protect lineman from energize secondary conductors. The linemen will cover the closest exposed/ Energized conductors. Ensure proper PPE is being worn.

Describe how ground assemblies are inspected and maintained?

Transmission and distribution ground assemblies shall be disassembled, cleaned, inspected and periodically tested.


A clear heat shrink sleeve with date tape installed under Under sleeve Shall be applied to each ground assembly that has passed testing. This is performed as part of the GARP.


The date tag shell indicate the month and year of testing grounds should not be used if the date tag is not legible, messing, or if the date is over 2 years old.

Grounds are to be inspected before each use. What is the procedure for inspecting a poll band?

Step 1: Inspect all bolts For mechanical integrity


Step 2: Check the Spring tension and latch assembly making sure they operate properly.


Step 3: Ensure there is a safety pin on the end of the chain. Verify the safety pin is not bent and it will properly engaged in the chain bail.


Step 4: Ensure the chain bail works properly and is not bent or deformed


Step 5: Inspect and clean the ground bar contact area.


Step 6: Inspect the chain for stretching or other signs of damage. If any of these conditions exist, replace the pole band

How do you conduct a meter panel inspection?

1. Identify hazards and methods to mitigate them.


2. I dentify in inspect PPE, tools and equipment.


3. Where correct PPE for job.


4. Visually inspect the meter panel for any defects.


5. Preform the following QC checks


A. Check service drops.


B. Check service drops supports.


C. Check location of service drops supports or point of building supports


D. Check service heads.


E. Check service entrance conductors and raceway


F. Check proper meter for service.


G. Check for proper height and proximity to other utilities.


H. Check panel security.


I. Tap on the panel to ensure there are no loose parts inside.


6. Check for back feed


7. Check for proper grounding scheme


A. I dentify the neutral and the proper location.


8. Check for continuity


A. Check phase to phase


B. Check phase to ground


C. Check neutral to ground

What are the methods for perp for me Pole top rescue.

Fast time method and body belt method.


The linemans body belt method can be used when lowering a victim from an elevated position.


The fast rope time method should be used only in the event of a cardiac arrest when it becomes necessary to lower the victim to the ground immediately so that CPR can be given while the Victom is in a horizontal position, a position that is infeasiblr to attain while on A-pole or structure

According to the APM, what are the main purpose is of performing pole top rescue?

The purpose in rescuing a person is to clear the victim from any immediate danger, Administer 1st aid and lower the victim to the ground.

How often must the user inspect climbing and protective equipment? List the area to check when inspecting belts, snap hooks, ropes and length adjusting devices.

Climbing and protective equipment should be inspected and maintained on a daily basis.


Wear and tear-cracks, cuts, Burns or tears in the leather, Loose or bent rivets, frayed or cut stitching, elongate it, torn or worn holes or Tools, loose or worn connection points for pouches or D ring's.


Snap hooks/metal- Cracks, distortion, corrosion or nicks, Gate closes and remains close until open, electrical Burns, Spring tension, improper latch movement.


Ropes-- Hard or compacted rope, Signs of inner red wearing course showing through, defects in rope or stitching eyes, pulled strands or wear and tear.


Length adjusting devices - cracks or corrosion to housing, Spring wire should be snug, split ring is securely seated through shoulder bolt.

What is the procedure for cutting a gain?

Perform a tailboard, verify integrity and depth of Pole, ascend pole using proper climbing techniques, drill a hole using proper tools and equipment used 11 16th inch drill bit for 5 eights whole , make horizontal cuts in pole for gain using framing saw. Cuts shall be between 5 eights and 7 eights inches in depth and should have approximately half inch wider with then the cross arm to assure proper fit. Remove material to create stable mounting surface using proper framing chisel and hammer. Perform QC check of gain ( hole centered in gain surface perpendicular to Pole, gain is square with Pole and has proper depth).


Descend pole using proper climbing techniques.

List at least 7 situations in which site protection is required.

The handling of exposed energized parts of equipment or systems energize and a 120 V or more between conductors.


Drilling or chipping stone, brick, concrete, paints come a pipe coating or metal.


Grinding come up buffing or wire brushing, whether there is a guard or not.


Dust or flying particle



Welding, cutting or burning


The use of hot or dangerous substances


Injurias light or heat rays


While mixing or working around injurious chemicals


When wearing a face shield where I protection is required


Any other job where there is recognized danger of eye injury

What are the basic tools needed to climb A-pole safely?

Body built, safety strap, rope safety, climbers

Whenever possible, should a single new pole structure be completely framed with cross arms, cross arm braces and pull steps before setting? Why or why not?

Yes, because it is easier to frame the poll on the ground than in the air.

Can still cross arms be installed on composite Poles?

No

What is the definition of a barricade?

A physical obstruction such as tapes, screens, or cones, etc. Intended to warn and limit access to hazardous areas.