Excavations less than 5 feet deep are exempt from Shoring and sloping according to OSHA true or false.

True

Trench 4 feet or more in-depth should be provided with a ladder for safe egress true or false

True

What is the minimum safe clearance between cranes and energized power lines operating at 50,000 volts or less

10 feet

For all excavations deeper than 20 feet the Shoring and side slopes should be determined by an engineer true or false

True

What is TLV

Threshold limit values

What type of fire is a type D fire extinguisher used for

Combustible metals

What type of fire can a Type B fire extinguisher put out

Gas oil and burning liquids

What type of fire does a type c fire extinguisher put out

Live electrical fires motor switches and appliances

How far should a ladder extend above its lean edge

3 feet

Working in a trench how far away can egress ladders be placed

25 feet

How far away can excavated material in soil be placed from the edge of excavation

2 feet or more

What's the rule of thumb for ladder angle

4 to 1 ratio

What is considered scaffolding

Any temporary elevated platform with its base structure design for supporting workers material or both

Guard rails and toe board shall be installed on all open sides and ends when scaffold or structure exceeds 10 feet above the ground, true or false

True

Guardrails shall be installed at what height

42 inches

Toe board shall be a minimum of

4 inches

What is the minimum size of a scaffold plank

2 inches x 10 inches

HEPA STANDS FOR

High-efficiency particulate absolute filter

OSHA stands for

Occupational safety and health administration

Empty acetylene cylinders should be stored upright kept and secured how far away from oxygen cylinders

Twenty feet apart or one hour fire wall

What three factors must be taken into account when determining trench design

Soil structure, weather and moisture conditions, trench depth

Two methods that may be used to protect workers in a trench

Sliding train Shields , metal and portable hydraulic shoring systems

Define confined space

Limited openings for egress, not designed for continuous worker occupancy, unfavorable natural ventilation

If there is less than 19.5% oxygen in the atmosphere it is considered oxygen-deficient true or false

True

MSDS stands for

Material safety data sheets

What type of oxides are given off while welding stainless

Nickel and chromium

What three methods can systemic poisons enter the body

Inhalation, ingestion, absorption

The permissible noise level exposure for 90 decibels is

8 hours

The permissible noise level exposure for 95 decibels is

4 hours

Ear plugs must be worn if the noise level is greater than

115 decibels

What type of fire does a type A fire extinguisher put out

Paper wood cloth

How is static electricity generated

By the contact and separation of dissimilar materials

What are the three Essential Elements necessary to produce an ordinary Flame

Fuel Heat and oxygen

What is the minimum allowable overhang on scaffold planks

6 inches

What are the harmful products of incomplete combustion

Carbon monoxide and aldehydes

Name the odorant used in natural gas and propane

Mercaptan

IDLH stands for

Immobility dangerous to life or health

Scaffold should support how many times the anticipated weight

4 x

The height of the scaffold platform shall not exceed 4X the minimum base dimensions true or false

True